The mechanical ventilation systems used in houses are designed to reduce carbon dioxide emissions while minimizing the energy loss resulting from ventilation. However, the increase in indoor fine particulate (PM2.5) concentration because of external PM2.5 influx through the ventilation system poses a problem. Here, we analyzed the changes in indoor PM2.5 concentration, distinguishing between cases of high and low outdoor PM2.5 concentrations and considering the efficiency of the filters used in residential mechanical ventilation systems. When using filters with the minimum efficiency reporting value (MERV) of 10 in the ventilation system, the outdoor PM2.5 concentration was 5 μg/m³; compared to the initial concentration, the indoor PM2.5 concentration after 60 min decreased to 73%. When the outdoor PM2.5 concentration was 30–40 μg/m³, the indoor PM2.5 concentration reached 91%. However, when MERV 13 filters were used, the indoor PM2.5 concentration consistently dropped to 73–76%, regardless of the outdoor PM2.5 concentration. Furthermore, by comparing the established equation with the mass balance model, the error was confirmed to be within 5%, indicating a good fit. This allows for the prediction of indoor PM2.5 under various conditions when using mechanical ventilation systems, enabling the formulation of strategies for maintaining indoor PM2.5, as recommended by the World Health Organization.
It is important to control airborne particles in residential houses for protecting human health. Indoor particulate matter of <2.5 μm (PM2.5) can be effectively monitored and managed using an air purifier. In this study, the actual clean air delivery rates in residential houses (CADRActual) were acquired by comparing decay rates of fine particles with and without operations of the air purifier under actual conditions, following the standard CADR of an air purifier obtained in a closed test chamber. The measurements of CADRActual at different outdoor PM2.5 concentrations over a month in two residential houses revealed different airtightness levels, compared to the standardized clean air delivery rate of the air purifier (CADRAP). Air changes per hour at 50 Pa (ACH50) was 4.8 h−1 for “house A” (built in 2007) and 2.1 h−1 for “house B” (built in 2018). The CADR of the air purifier used in this study was 10.6 m3/min, while the averaged CADRActual at the “house A” was 7.2 m3/min (approximately 66% of the CADR of the air purifier) and 9.5 m3/min at “house B” (approximately 90% of the CADR of the air purifier). Under the outdoor PM2.5 concentrations of 35 μg/m3, the analogous averaged concentrations were 6.8 ± 0.6 and 9.6 ± 0.3 m3/min for houses A and B, respectively. The measured CADRActual agreed well with the theoretical estimates of CADRActual acquired by the mass balance equation using the infiltration rate of ACH50/20. We also estimated CADRActual/CADRAP for house C built in 2017, where the ACH50 was 1.8 h−1. Overall, this study demonstrated how CADRActual/CADRAP of an air purifier at residential houses can be predicted according to outdoor PM2.5 concentration and airtightness of the house. As shown, it can be closer to 1 at lower ACH50 houses and at lower outdoor PM2.5 concentrations.
The educational and play-related activities of children proceed mainly indoors in a kindergarten. High concentrations of indoor PM2.5 and CO2 have been linked to various harmful effects on children, considerably impacting their educational outcomes in kindergarten. In this study, we explore different scenarios involving the operation of mechanical ventilation systems and air purifiers in kindergartens. Using numerical models to analyze indoor CO2 and PM2.5 concentration, we aim to optimize strategies that effectively reduce these harmful pollutants. We found that the amount of ventilation required to maintain good air quality, per child, was approximately 20.4 m3/h. However, we also found that as the amount of ventilation increased, so did the concentration of indoor PM2.5; we found that this issue can be resolved using a high-grade filter (i.e., a MERV 13 grade filter with a collection efficiency of 75%). This study provides a scientific basis for reducing PM2.5 concentrations in kindergartens, while keeping CO2 levels low.
Indoor PM2.5 in apartments must be effectively managed to minimize adverse impacts on human health. Cooking is the one of the main PM2.5 sources in apartments, and indoor air quality (IAQ) management methods (natural ventilation, mechanical ventilations, range hoods, and air purifiers) are typically used to reduce PM2.5 generated during cooking. For effective control of indoor PM2.5 , prediction of PM2.5 reduction for various IAQ management methods is necessary. This study carefully predicted indoor PM2.5 concentrations in an apartment when IAQ management methods were applied separately and/or in combination during cooking. The infiltration and exfiltration were verified by comparing the experimental results of CO2 concentration with those predicted with or without mechanical ventilation. The deposition rate for PM2.5 generated by cooking was also derived by comparing the experimental PM2.5 changes with the predicted values for PM2.5 natural decay. Through this method, effective PM2.5 control ways during cooking in apartments can be proposed, such as natural ventilation with a range hood for 30 min and then the operation of an air purifier for 30 min. Additionally, if this prediction is combined with energy consumption, it will be possible to propose the most energy-efficient indoor PM2.5 control methods for various seasons and outdoor conditions.
Indoor PM2.5 must be effectively controlled to minimize adverse impacts on public health. Cooking is one of the main sources of PM2.5 in residential areas, and indoor air quality (IAQ) management methods such as natural and mechanical ventilation, range hood, and air purifier are typically used to reduce cooking-generated PM2.5 concentrations. However, studies on the combined effects of various IAQ management methods on indoor PM2.5 reduction and energy consumption are limited. In this study, a theoretical model was established to estimate the performance of various IAQ management methods for controlling indoor PM2.5 concentrations and energy consumption. The model was verified by comparative experiments in which, various IAQ management methods were operated individually or combined. Seasonal energy consumption was calculated through the verified model, and energy consumption saving scenarios were derived for maintaining indoor PM2.5 concentrations less than 10 μg/m3, a World Health Organization annual guideline, under fair and poor outdoor PM2.5 concentrations of 15 and 50 μg/m3, respectively. Based on our results, we found that energy consumption could be reduced significantly by applying natural ventilation in spring, autumn, and summer and mechanical ventilation in winter. Our study identified efficient energy saving PM2.5 management scenarios using various IAQ management methods by predicting indoor PM2.5 concentration and energy consumption according to the annual life patterns of typical residents in South Korea.
Mechanical ventilation systems used in houses are designed to reduce carbon dioxide emissions while minimizing the energy loss resulting from ventilation. However, increase in indoor fine particulate (PM2.5) concentration because of external PM2.5, influx through the ventilation system poses a problem. In this study, we analyzed the changes in indoor PM2.5 concentrations via dis-tinguishing between cases of high and low outdoor PM2.5 concentrations, considering the effi-ciency of filters used in residential mechanical ventilation systems. When using minimum effi-ciency reporting value (MERV) 10 filters in the ventilation system, the outdoor PM2.5 concentra-tion was 5 μg/m³; the indoor PM2.5 concentration became 73% after 60 min compared to the ini-tial. When the outdoor PM2.5 concentration was 30–40 μg/m³, the indoor PM2.5 concentration reached 91%. However, when MERV 13 filters were used, the indoor PM2.5 concentration con-sistently dropped to 73–76% regardless of the outdoor PM2.5 concentration. Furthermore, by comparing the established equation with the mass-balance model, the error was confirmed to be within 5%, indicating good fit. This allows the prediction of indoor PM2.5 under various condi-tions when using mechanical ventilation systems, enabling the formulation of strategies to maintain indoor PM2.5 as recommended by the World Health Organization.