We developed a novel electrostatic air purifier using a carbon fiber brush charger combined with a metallic collection rod and an activated carbon fiber (ACF) sheet to improve the indoor air quality of passenger vehicles. The ACF sheet was used to apply electrostatic forces to move charged particles toward a collection rod and simultaneously adsorb gas. The cylindrical air purifier (diameter: 100 mm, length: 190 mm) was composed of a conductive brush charger and an electrostatic collection rod for particle removal, as well as an ACF filter for gas removal. The flow rate of the device was approximately 209-360 L/min. The novel purifier was tested in a 1-m 3 chamber with particles 0.3 μm in diameter and three gases: ammonia, acetic acid, and acetaldehyde. The gas cleaning performance of the purifier was compared with that of a commercial purifier with a high-efficiency particulate air (HEPA) filter, activated carbon pellets, and alumina balls. The clean air delivery rate (CADR) of the novel electrostatic air cleaner was 0.219 m 3 /min, 35% higher than that of the HEPA filter. The CADRs of the ESP air cleaner for the test gases were 0.25, 0.19, and 0.19 m 3 /min, respectively, indicating that the novel ESP air cleaner reduced the gases 308%, 204%, and 327%, respectively, faster than the commercial purifier.
5 July 2018 in IEEE Transactions on Industry Applications
A wet packed bed scrubber combined with dry oxidation by indirect DBD plasma for conversion of NO to NO2 and wet reduction with two reduction agents of Na2S and Na2SO3 to remove NO2 was developed at room temperature for semiconductor manufacturing industries. The design and operation parameter for the wet scrubber such as gas concentration, liquid to gas ratio, reducing agent concentration, residence time and pressure drop were investigated at 2 m3/min and 200 ppm of pure NO gas. Na2S solution was more suitable than Na2SO3 with less chemical consumption and liquid to gas ratio. Removal efficiency over 80% was achieved with liquid to gas ratio of 10 L/m3, reduction agent solution of 0.1% w/w which corresponds to ORP of -310 mV and pH of 12.3, residence time of 2 sec, and pressure drop of 25 mmAq/m, respectively. Finally, a demonstration test of the wet scrubber was conducted for 1 month with exhaust gas from perfluorinated compounds (PFCs) gas scrubber at the rooftop of a semiconductor manufacturing plant in Korea. In order to suppress H2S as byproducts of the wet scrubber, pH over 12 was carefully controlled with NaOH solution because commonly highly acid gases such as HF and HCl were fed from the manufacturing process. The NOx removal efficiency was average 83.8% which was very similar to those obtained from the lab tests. These results indicate that the combination of the dry oxidation and wet reduction method could be a promising solution to remove NOx from semiconductor manufacturing industries.
26 October 2021 in IEEE Transactions on Industry Applications
Electrostatic precipitators (ESPs) are widely used to control air pollution. However, their applications in portable air cleaners are limited owing to ozone generation during the discharging process. In this article, we developed a compact two-stage ESP that combines corona discharging and particle collection modules. The former generates an extremely small amount of ozone using dielectric film coating, whereas the latter has a large specific surface area. A polypropylene (PP) film is coated as a dielectric material on the ground electrode of the discharging module. The corona current is reduced by the PP film, which in turn reduces the ozone generation. The efficiency of atmospheric particle collection and ozone generation were evaluated by varying the flow rates and applied voltages of the four-channel discharging and roll-type collection modules. Additionally, the specific surface area of 707 m2/m3 of the roll-type collection module minimized the size of the device by increasing its integrity. The proposed ESP with PP coating exhibited the tendency of a conventional ESP that follows the Deutsch equation. All particles of size over 1 μm were removed from the atmosphere by the proposed device at a flow rate of 194.4 L/min, which is more than three times that of human breathing. Furthermore, our experimental device removed more than 50% of the ultrafine particles of size 0.3 μm without ozone generation. Therefore, the proposed device can be potentially used in portable or wearable air-cleaning devices to aid individual healthcare.
The mechanical ventilation systems used in houses are designed to reduce carbon dioxide emissions while minimizing the energy loss resulting from ventilation. However, the increase in indoor fine particulate (PM2.5) concentration because of external PM2.5 influx through the ventilation system poses a problem. Here, we analyzed the changes in indoor PM2.5 concentration, distinguishing between cases of high and low outdoor PM2.5 concentrations and considering the efficiency of the filters used in residential mechanical ventilation systems. When using filters with the minimum efficiency reporting value (MERV) of 10 in the ventilation system, the outdoor PM2.5 concentration was 5 μg/m³; compared to the initial concentration, the indoor PM2.5 concentration after 60 min decreased to 73%. When the outdoor PM2.5 concentration was 30–40 μg/m³, the indoor PM2.5 concentration reached 91%. However, when MERV 13 filters were used, the indoor PM2.5 concentration consistently dropped to 73–76%, regardless of the outdoor PM2.5 concentration. Furthermore, by comparing the established equation with the mass balance model, the error was confirmed to be within 5%, indicating a good fit. This allows for the prediction of indoor PM2.5 under various conditions when using mechanical ventilation systems, enabling the formulation of strategies for maintaining indoor PM2.5, as recommended by the World Health Organization.
22 March 2022 in IEEE Transactions on Industry Applications
This study developed a highly efficient electrostatic precipitator (ESP) type air conditioner to reduce the particulate matter (PM) concentration in a subway station. A polyethylene terephthalate film coated carbon sheet nonmetallic electrode was used as a collection plate to reduce the weight instead of the metallic collection plate, and the carbon fiber ionizer was used to minimize the ozone generation. When the flow velocity in a duct was 1 m/s with −5.0 kV applied to the ionizer and −5.0 kV to the collection plates, the 0.3- μ m PM 0.3 removal efficiency increased up to 97.47%. Holes in the collection plates were used to attach connecting tubes to maintain a constant distance. The strength and shape of the electric field were analyzed using COMSOL. The electric field quickly dissipated in the hole areas, and the field strength converged to 0. The collection plates were extended to compensate for the reduced collection area due to the holes. As a result, when the flow rate in the duct was 1 m/s, −5.0 kV was applied to the ionizer, and the electric field strength was up to −1.5 kV/mm, the PM 0.3 removal efficiency was increased to 99.08%. This behavior resembled that of conventional collection plates. The ESP developed in this study corresponds to a higher MERV13 grade than the MERV10 grade filter currently installed in the air conditioner of the subway station and has almost no pressure drop, so it is expected to contribute to the improvement of air quality and energy efficiency of subway stations.