Bangwoo Han

Prof. Dr. Bangwoo Han


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Hak-Joon KimHak-Joon Kim
Hak-Joon Kim
BHBangwoo Han
Bangwoo Han
CWChang Gyu Woo
Chang Gyu Woo
YKYongjin Kim
Yongjin Kim
A wet packed bed scrubber combined with dry oxidation by indirect DBD plasma for conversion of NO to NO2 and wet reduction with two reduction agents of Na2S and Na2SO3 to remove NO2 was developed at room temperature for semiconductor manufacturing industries. The design and operation parameter for the wet scrubber such as gas concentration, liquid to gas ratio, reducing agent concentration, residence time and pressure drop were investigated at 2 m3/min and 200 ppm of pure NO gas. Na2S solution was more suitable than Na2SO3 with less chemical consumption and liquid to gas ratio. Removal efficiency over 80% was achieved with liquid to gas ratio of 10 L/m3, reduction agent solution of 0.1% w/w which corresponds to ORP of -310 mV and pH of 12.3, residence time of 2 sec, and pressure drop of 25 mmAq/m, respectively. Finally, a demonstration test of the wet scrubber was conducted for 1 month with exhaust gas from perfluorinated compounds (PFCs) gas scrubber at the rooftop of a semiconductor manufacturing plant in Korea. In order to suppress H2S as byproducts of the wet scrubber, pH over 12 was carefully controlled with NaOH solution because commonly highly acid gases such as HF and HCl were fed from the manufacturing process. The NOx removal efficiency was average 83.8% which was very similar to those obtained from the lab tests. These results indicate that the combination of the dry oxidation and wet reduction method could be a promising solution to remove NOx from semiconductor manufacturing industries.

21 May 2015 in Aerosol Science and Technology
Verified
Journal Article
Open access
CWChang Gyu Woo
Chang Gyu Woo
JKJi-Soo Kang
Ji-Soo Kang
HKHak-Joon Kim
Hak-Joon Kim
YKYong-Jin Kim
Yong-Jin Kim
BHBangwoo Han
Bangwoo Han
Two natural products; i.e., grapefruit seed extract (GSE) and propolis, were investigated for use in antimicrobial air filters. Staphylococcus aureus was investigated as a test bioaerosol, and was deposited on the antimicrobial filters, which were treated by spraying with various areal densities of GSE and propolis. The pressure drop and particle penetration were investigated to assess the filtration performance of the bioaerosol, and the bacterial-inactivation performance of the filters was evaluated by quantifying S. aureus. There was little change in the pressure drop as a function of the areal density of GSE up to 185.9 μg/cm2; however, a significant change in the pressure drop was found for the air filter coated with propolis at an areal density of 98.4 μg/cm2. The penetration levels of bioaerosols in both filters were uniform and in the range 1.4–2.0% (based on particle number), regardless of the areal density of the deposited GSE or propolis. The inactivation rates of the filters with identical deposition masses of GSE and propolis were similar in the ranges of 92.1–100%, 75.2–89.1%, and 54.4–75.5% at the control filters with colony numbers of 103, 104, and 105 CFU/mL, respectively. The bacterial inactivation rate could be described by an exponential function of the areal density of GSE/propolis per number of colonies. Copyright 2015 American Association for Aerosol Research

26 October 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YLYeawan Lee
Yeawan Lee
YKYe-Sle Kim
Ye-Sle Kim
BHBangwoo Han
Bangwoo Han
YKYongjin Kim
Yongjin Kim
Hak-Joon KimHak-Joon Kim
Hak-Joon Kim
Electrostatic precipitators (ESPs) are widely used to control air pollution. However, their applications in portable air cleaners are limited owing to ozone generation during the discharging process. In this article, we developed a compact two-stage ESP that combines corona discharging and particle collection modules. The former generates an extremely small amount of ozone using dielectric film coating, whereas the latter has a large specific surface area. A polypropylene (PP) film is coated as a dielectric material on the ground electrode of the discharging module. The corona current is reduced by the PP film, which in turn reduces the ozone generation. The efficiency of atmospheric particle collection and ozone generation were evaluated by varying the flow rates and applied voltages of the four-channel discharging and roll-type collection modules. Additionally, the specific surface area of 707 m2/m3 of the roll-type collection module minimized the size of the device by increasing its integrity. The proposed ESP with PP coating exhibited the tendency of a conventional ESP that follows the Deutsch equation. All particles of size over 1 μm were removed from the atmosphere by the proposed device at a flow rate of 194.4 L/min, which is more than three times that of human breathing. Furthermore, our experimental device removed more than 50% of the ultrafine particles of size 0.3 μm without ozone generation. Therefore, the proposed device can be potentially used in portable or wearable air-cleaning devices to aid individual healthcare.

7 November 2023 in Toxics
Verified
Journal Article
Open access
PDF file
DSDongho Shin
Dongho Shin
YKYounghun Kim
Younghun Kim
KHKeejung Hong
Keejung Hong
GLGunhee Lee
Gunhee Lee
IPInyong Park
Inyong Park
BHBangwoo Han
Bangwoo Han
The mechanical ventilation systems used in houses are designed to reduce carbon dioxide emissions while minimizing the energy loss resulting from ventilation. However, the increase in indoor fine particulate (PM2.5) concentration because of external PM2.5 influx through the ventilation system poses a problem. Here, we analyzed the changes in indoor PM2.5 concentration, distinguishing between cases of high and low outdoor PM2.5 concentrations and considering the efficiency of the filters used in residential mechanical ventilation systems. When using filters with the minimum efficiency reporting value (MERV) of 10 in the ventilation system, the outdoor PM2.5 concentration was 5 μg/m³; compared to the initial concentration, the indoor PM2.5 concentration after 60 min decreased to 73%. When the outdoor PM2.5 concentration was 30–40 μg/m³, the indoor PM2.5 concentration reached 91%. However, when MERV 13 filters were used, the indoor PM2.5 concentration consistently dropped to 73–76%, regardless of the outdoor PM2.5 concentration. Furthermore, by comparing the established equation with the mass balance model, the error was confirmed to be within 5%, indicating a good fit. This allows for the prediction of indoor PM2.5 under various conditions when using mechanical ventilation systems, enabling the formulation of strategies for maintaining indoor PM2.5, as recommended by the World Health Organization.

22 March 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
HLHaneol Lee
Haneol Lee
JSJin-Ho Sung
Jin-Ho Sung
MKMoonwon Kim
Moonwon Kim
YKYe-Sle Kim
Ye-Sle Kim
YLYeawan Lee
Yeawan Lee
Hak-Joon KimHak-Joon Kim
Hak-Joon Kim
This study developed a highly efficient electrostatic precipitator (ESP) type air conditioner to reduce the particulate matter (PM) concentration in a subway station. A polyethylene terephthalate film coated carbon sheet nonmetallic electrode was used as a collection plate to reduce the weight instead of the metallic collection plate, and the carbon fiber ionizer was used to minimize the ozone generation. When the flow velocity in a duct was 1 m/s with −5.0 kV applied to the ionizer and −5.0 kV to the collection plates, the 0.3- μ m PM 0.3 removal efficiency increased up to 97.47%. Holes in the collection plates were used to attach connecting tubes to maintain a constant distance. The strength and shape of the electric field were analyzed using COMSOL. The electric field quickly dissipated in the hole areas, and the field strength converged to 0. The collection plates were extended to compensate for the reduced collection area due to the holes. As a result, when the flow rate in the duct was 1 m/s, −5.0 kV was applied to the ionizer, and the electric field strength was up to −1.5 kV/mm, the PM 0.3 removal efficiency was increased to 99.08%. This behavior resembled that of conventional collection plates. The ESP developed in this study corresponds to a higher MERV13 grade than the MERV10 grade filter currently installed in the air conditioner of the subway station and has almost no pressure drop, so it is expected to contribute to the improvement of air quality and energy efficiency of subway stations.

1 June 2020 in Fuel
Verified
Journal Article
Closed access
DSDongho Shin
Dongho Shin
CWChang Gyu Woo
Chang Gyu Woo
KHKee-Jung Hong
Kee-Jung Hong
Hak-Joon KimHak-Joon Kim
Hak-Joon Kim
YKYong-Jin Kim
Yong-Jin Kim
SCSung-Nam Chun
Sung-Nam Chun