Zehui Xiang

Zehui Xiang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2022 in Coatings
Verified
Journal Article
Open access
PDF file
JWJingSong Wang
JingSong Wang
JNJiangang Niu
Jiangang Niu
ZXZehui Xiang
Zehui Xiang
JZJie Zhou
Jie Zhou
JWJun Wang
Jun Wang
To explore the crack behaviors of corroded concrete columns jointly reinforced by concrete canvas (CC) and carbon fiber reinforced polymer (CFRP), a total of six specimen sets with different reinforcement forms and corrosion rates are designed and tested by acoustic emission (AE) technology. The assessed methods are AE characteristic parameters, RA-AF values, b values, and AE event spatial location map. The results show that the presence of CC changes the failure morphology of the specimen and improves the uneven deformation of concrete in the core area, which proves that the jointly reinforced method exhibits high plasticity deformation ability. The crack mode of the jointly reinforced specimen undergoes multiple transformations between tensile cracks and shear cracks, before ending in the final crush failure. The fluctuations in both amplitude and frequency of the b values of the jointly reinforced specimens increase significantly with time. The crack activity of concrete is more intense in this period, which proves that the jointly reinforced method ensures a more complete failure. Moreover, the increases in corrosion rate reduced the probability of shear cracks in the core concrete and further increased the failure degree of the specimen. The present study demonstrated that AE monitoring can effectively capture the characteristics of the cracking process of jointly reinforced concrete.

7 December 2022 in Buildings
Verified
Journal Article
Open access
PDF file
ZXZehui Xiang
Zehui Xiang
JWJun Wang
Jun Wang
JNJiangang Niu
Jiangang Niu
YXYao Xu
Yao Xu
To study the seismic performance of hollow columns with fiber lightweight aggregate concrete, a quasi-static test on eight hollow columns with fiber lightweight aggregate concrete under lateral low-cycle reversed loading and axial force is presented in this article. The effects of the dosage of plastic-steel fibers (0, 3, 6 and 9 kg/m3, respectively), steel fibers (25, 50 and 75 kg/m3, respectively) and the axial compression ratio (0.4 and 0.6, respectively) on the seismic mechanical properties such as capacity under lateral load, stiffness, ductility and energy dissipation were investigated, and the main failure morphology and force mechanism of hollow columns with fiber lightweight aggregate concrete under lateral low-cycle reversed loading were revealed. The results showed that (1) the failure modes of hollow columns could be divided into shear failure, bending-shear failure and bending failure; (2) compared with the specimens without fiber, the increase in ductility coefficient of specimens with plastic-steel fiber was 2~33.7%, and that with steel fiber was 30.8~125.7%; the increase in cumulative energy dissipation of specimens with plastic-steel fiber was 5.3~43.7%, and that with steel fiber was 88.9~203.8%, thus indicating that the seismic performance of the specimens could be improved effectively via the incorporation of fibers. The formula of shear capacity under lateral load was proposed, and its calculation results were more reliable when compared with the actual project. A foundation for further research on the seismic performance of hollow columns with fiber lightweight aggregate concrete is provided.

15 March 2024 in Buildings
Verified
Journal Article
Open access
PDF file
FLFengge Li
Fengge Li
CCChen Chen
Chen Chen
ZXZehui Xiang
Zehui Xiang
To investigate the effects of concrete canvas (CC) and carbon fiber reinforced plastic (CFRP) reinforcement on the mechanical properties of corroded reinforced concrete columns (compressive strength, flexure strength, strength of extension, and so on), 42 columns in four groups were designed and axial compression experiments were carried out. For the corroded reinforced concrete columns reinforced with CC and CFRP, the effects of initial corrosion rate (5%, 10%), secondary corrosion time (15 d, 30 d), number of CC layers (0, 1), and number of CFRP layers (1, 2, 3) on the failure morphology, load carrying capacity, and ductility of concrete columns were analyzed. The test results show that the properties of the single layer CC confined specimens are improved to a certain extent, and the ductility properties are enhanced. The properties of the CC–CFRP composite constrained specimens are greatly improved, the plastic deformation ability is enhanced, and the typical ductile damage characteristics are shown. The corrosion inhibition of CC for specimens with a theoretical corrosion rate lower than 20% showed an increasing trend, and the corrosion inhibition rate ranged from 23.0% to 31.2%. CC and CFRP restrain the concrete jointly, hindering the expansion inside the concrete, and the peak strain of the joint restraint specimen itself changes greatly, while the overall peak strain of the corrosion specimen is very small under the action of the joint steel bar. Finally, according to the existing peak stress–strain model and the experimental data in this paper, a peak stress–strain model suitable for corroded reinforced concrete columns is established. The established calculation model has a high accuracy, which provides a certain theoretical basis for subsequent research.