To explore the crack behaviors of corroded concrete columns jointly reinforced by concrete canvas (CC) and carbon fiber reinforced polymer (CFRP), a total of six specimen sets with different reinforcement forms and corrosion rates are designed and tested by acoustic emission (AE) technology. The assessed methods are AE characteristic parameters, RA-AF values, b values, and AE event spatial location map. The results show that the presence of CC changes the failure morphology of the specimen and improves the uneven deformation of concrete in the core area, which proves that the jointly reinforced method exhibits high plasticity deformation ability. The crack mode of the jointly reinforced specimen undergoes multiple transformations between tensile cracks and shear cracks, before ending in the final crush failure. The fluctuations in both amplitude and frequency of the b values of the jointly reinforced specimens increase significantly with time. The crack activity of concrete is more intense in this period, which proves that the jointly reinforced method ensures a more complete failure. Moreover, the increases in corrosion rate reduced the probability of shear cracks in the core concrete and further increased the failure degree of the specimen. The present study demonstrated that AE monitoring can effectively capture the characteristics of the cracking process of jointly reinforced concrete.
To study the seismic performance of hollow columns with fiber lightweight aggregate concrete, a quasi-static test on eight hollow columns with fiber lightweight aggregate concrete under lateral low-cycle reversed loading and axial force is presented in this article. The effects of the dosage of plastic-steel fibers (0, 3, 6 and 9 kg/m3, respectively), steel fibers (25, 50 and 75 kg/m3, respectively) and the axial compression ratio (0.4 and 0.6, respectively) on the seismic mechanical properties such as capacity under lateral load, stiffness, ductility and energy dissipation were investigated, and the main failure morphology and force mechanism of hollow columns with fiber lightweight aggregate concrete under lateral low-cycle reversed loading were revealed. The results showed that (1) the failure modes of hollow columns could be divided into shear failure, bending-shear failure and bending failure; (2) compared with the specimens without fiber, the increase in ductility coefficient of specimens with plastic-steel fiber was 2~33.7%, and that with steel fiber was 30.8~125.7%; the increase in cumulative energy dissipation of specimens with plastic-steel fiber was 5.3~43.7%, and that with steel fiber was 88.9~203.8%, thus indicating that the seismic performance of the specimens could be improved effectively via the incorporation of fibers. The formula of shear capacity under lateral load was proposed, and its calculation results were more reliable when compared with the actual project. A foundation for further research on the seismic performance of hollow columns with fiber lightweight aggregate concrete is provided.