Human immunodeficiency virus (HIV) is a global health problem. Early diagnosis, rapid antiretroviral therapy (ART) initiation and monitoring of viral load are the key strategies for effective HIV management. Many people in resource limited settings where timely access to medical care is a challenge and healthcare infrastructure is poor have no access to laboratory facilities and diagnosis is dependent on the presence of point of care (POC) devices. POC instruments have shown to be easy to operate, maintain and transport and can easily be operated by less skilled health workers. Additionally, POC tests do not require laboratory technicians to operate. POC devices have resulted in a growing number of people testing for HIV and thereby receiving treatment early. In recent years, there has been great improvement in the development of POC technologies for early HIV diagnosis, HIV viral load and cluster of differentiation 4 (CD4) measurement. This review discusses POC technologies that are currently available and in the pipeline for diagnosing and monitoring HIV. We also give an overview of the technical and commercialization challenges in POC diagnostics for HIV.
Photodynamic therapy (PDT) involves interaction of a photosensitizer, light, and molecular oxygen which produces singlet oxygen and subsequent tumour eradication. The development of second generation photosensitizers, such as phthalocyanines, has improved this technology. Customary monolayer cell culture techniques are, unfortunately, too simple to replicate treatment effects in vivo. Multicellular tumour spheroids may provide a better alternative since they mimic aspects of the human tumour environment. This study aimed to profile 84 genes involved in apoptosis following treatment with PDT on lung cancer cells (A549) grown in a monolayer versus three-dimensional multicellular tumour spheroids (250 and 500 μm). Gene expression profiling was performed 24 h post irradiation (680 nm; 5 J/cm2) with zinc sulfophthalocyanine (ZnPcSmix) to determine the genes involved in apoptotic cell death. In the monolayer cells, eight pro-apoptotic genes were upregulated, and two were downregulated. In the multicellular tumour spheroids (250 µm) there was upregulation of only 1 gene while there was downregulation of 56 genes. Apoptosis in the monolayer cultured cells was induced via both the intrinsic and extrinsic apoptotic pathways. However, in the multicellular tumour spheroids (250 and 500 µm) the apoptotic pathway that was followed was not conclusive.
The interaction between nanoparticles and the electromagnetic fields associated with optical nanostructures enables sensing with single-nanoparticle limits of detection and digital resolution counting of captured nanoparticles through their intrinsic dielectric permittivity, absorption, and scattering. This paper will review the fundamental sensing methods, device structures, and detection instruments that have demonstrated the capability to observe the binding and interaction of nanoparticles at the single-unit level, where the nanoparticles are comprised of biomaterial (in the case of a virus or liposome), metal (plasmonic and magnetic nanomaterials), or inorganic dielectric material (such as TiO2 or SiN). We classify sensing approaches based upon their ability to observe single-nanoparticle attachment/detachment events that occur in a specific location, versus approaches that are capable of generating images of nanoparticle attachment on a nanostructured surface. We describe applications that include study of biomolecular interactions, viral load monitoring, and enzyme-free detection of biomolecules in a test sample in the context of in vitro diagnostics.