The uniaxial monotonic compressive stress-strain behavior and other characteristics of unreinforced masonry and its constituents, i.e., solid clay bricks and mortar, have been studied by several laboratory tests. Based on the results and observations of the comprehensive experimental study, nonlinear stress-strain curves have been obtained for bricks, mortar, and masonry and six “control points” have been identified on the stress-strain curves of masonry, which can also be used to define the performance limit states of the masonry material or member. Using linear regression analysis, a simple analytical model has been proposed for obtaining the stress-strain curves for masonry that can be used in the analysis and design procedures. The model requires only the compressive strengths of bricks and mortar as input data, which can be easily obtained experimentally and also are generally available in codes. Simple relationships have been identified for obtaining the modulus of elasticity of bricks, mortar, and ...
1 August 2017 in Journal of Composites for Construction
Strengthening of unreinforced masonry walls is essential to mitigate their brittle failure during natural hazards like earthquakes. An experimental program was conducted to evaluate the diagonal shear and out-of-plane flexural strength of masonry walletes strengthened using glass fabric–reinforced cementitious matrix (FRCM). The performance of walletes strengthened in two modes of wet lay-up application: direct and sandwich, which differ in the sequence of placing the fabric, was studied. Also, the contribution of mechanical anchors was investigated in enhancing the performance of masonry subassemblages. Test results showed that with the provision of FRCM, the strength and ductility of masonry could be significantly improved under both shear and flexural loads, and the brittle collapse could be mitigated. Both methods of FRCM application showed comparable results, and it was observed that the mechanical anchors were helpful in attaining higher deformability and in containing the broken fragments of masonry. Finally, the strength parameters obtained from these tests were compared with those predicted using existing analytical models for strengthened masonry walls.
7 April 2009 in Earthquake Engineering & Structural Dynamics
Strengthening of masonry-infilled reinforced concrete (RC) frame buildings with an open first story is needed because of the inherent irregularity in such buildings resulting in their poor performance as observed during several past earthquakes. In the present study, several strengthening schemes were evaluated for their effectiveness in improving the performance of such buildings, based on nonlinear analyses of typical RC frames. Instead of using predetermined multiplying factors for designing the first-story members for higher forces as recommended in some national codes, a rational method was developed for the calculation of the required increase in strength of open first-story columns. Other strengthening schemes studied were providing additional columns, diagonal bracings, and lateral buttresses in the open first story. Code methods were found to increase only lateral strength (and not the ductility) of such frames; whereas, some of the alternate schemes studied were found to improve both lateral str...
13 February 2014 in Geomatics, Natural Hazards and Risk
The M7.8 earthquake of 25th April, 2015 caused widespread damage in the Nepal region by destroying many residential, public, religious and cultural heritage buildings and roads due to intense shaking, surface fissures and landslides. This earthquake provided an opportunity to study the vulnerability of the built environment and reassessment of the risk exposure of the region. The reconnaissance trip was aimed at surveying the Kathmandu valley region in Nepal and adjoining districts of Bihar state in India due to their high population density and rapid urbanization. The observed damage in Kathmandu and the northern districts of Bihar were consistent with the intensity reported in these regions. Complete collapse was observed in RC buildings and old unreinforced masonry buildings due to inherent structural defects in regions of MM intensity VIII and IX. Significant number of cultural heritage structures suffered partial to complete collapse. These observations provide a perspective on the widespread lack of preparedness even when the seismic hazard of the Himalayan region is well established. This letter cites some of the poor construction practices that are followed in the Kathmandu valley region which make the built environment vulnerable to unacceptable levels of damage under expected design levels of shaking.
21 July 2016 in Earthquake Engineering & Structural Dynamics