Chuanren Wu

Dr. Chuanren Wu

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2022 in Fusion Engineering and Design
Verified
Journal Article
Open access
MTM.Q. Tran
M.Q. Tran
PAP. Agostinetti
P. Agostinetti
Gaetano AielloGaetano Aiello
Gaetano Aiello
KAK. Avramidis
K. Avramidis
BBB. Baiocchi
B. Baiocchi
WZW. Zhang
W. Zhang

1 November 2017 in Fusion Engineering and Design
Verified
Journal Article
Open access
JJJohn Jelonnek
John Jelonnek
Gaetano AielloGaetano Aiello
Gaetano Aiello
SAS. Alberti
S. Alberti
KAK. Avramidis
K. Avramidis
FBF. Braunmueller
F. Braunmueller
MTMinh Tran
Minh Tran

1 July 2021 in Fusion Engineering and Design
Verified
Journal Article
Closed access
TFT. Franke
T. Franke
Gaetano AielloGaetano Aiello
Gaetano Aiello
KAK. Avramidis
K. Avramidis
CBChristian Bachmann
Christian Bachmann
BBB. Baiocchi
B. Baiocchi
HZH. Zohm
H. Zohm

1 March 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
CWChuanren Wu
Chuanren Wu
IPIoannis Gr. Pagonakis
Ioannis Gr. Pagonakis
KAKonstantinos A. Avramidis
Konstantinos A. Avramidis
GGGerd Gantenbein
Gerd Gantenbein
SIStefan Illy
Stefan Illy
JJJohn Jelonnek
John Jelonnek
Multistage Depressed Collectors (MDCs) are widely used in vacuum tubes to regain energy from the depleted electron beam. However, the design of an MDC for gyrotrons, especially for those deployed in fusion experiments and future power plants, is not trivial. Since gyrotrons require relatively high magnetic fields, their hollow annular electron beam is magnetically confined in the collector. In such a moderate magnetic field, the MDC concept based on E × B drift is very promising. Several concrete design approaches based on the E × B concept have been proposed. This paper presents a realizable design of a two-stage depressed collector based on the E × B concept. A collector efficiency of 77% is achievable, which will be able to increase the total gyrotron efficiency from currently 50% to more than 60%. Secondary electrons reduce the efficiency only by 1%. Moreover, the collector efficiency is resilient to the change of beam current (i.e., space charge repulsion) and beam misalignment as well as magnetic field perturbations. Therefore, compared to other E × B conceptual designs, this design approach is promising and fairly feasible.

31 March 2017 in Physics of Plasmas
Verified
Journal Article
Closed access
CWChuanren Wu
Chuanren Wu
IPIoannis Gr. Pagonakis
Ioannis Gr. Pagonakis
GGGerd Gantenbein
Gerd Gantenbein
SIStefan Illy
Stefan Illy
MTManfred Thumm
Manfred Thumm
JJJohn Jelonnek
John Jelonnek
Multistage depressed collectors are challenges for high-power, high-frequency fusion gyrotrons. Two concepts exist in the literature: (1) unwinding the spent electron beam cyclotron motion utilizing non-adiabatic transitions of magnetic fields and (2) sorting and collecting the electrons using the E × B drift. To facilitate the collection by the drift, the hollow electron beam can be transformed to one or more thin beams before applying the sorting. There are many approaches, which can transform the hollow electron beam to thin beams; among them, two approaches similar to the tilted electric field collectors of traveling wave tubes are conceptually studied in this paper: the first one transforms the hollow circular electron beam to an elongated elliptic beam, and then the thin elliptic beam is collected by the E × B drift; the second one splits an elliptic or a circular electron beam into two arc-shaped sheet beams; these two parts are collected individually. The functionality of these concepts is proven by CST simulations. A model of a three-stage collector for a 170 GHz, 1 MW gyrotron using the latter approach shows 76% collector efficiency while taking secondary electrons and realistic electron beam characteristics into account.

17 January 2023 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
BEBenjamin Felix Ell
Benjamin Felix Ell
CWChuanren Wu
Chuanren Wu
GGGerd Gantenbein
Gerd Gantenbein
SIStefan Illy
Stefan Illy
MMMoritz Stefan Misko
Moritz Stefan Misko
JJJohn Jelonnek
John Jelonnek
The multistage depressed collector (MDC) is essential to significantly increase the overall efficiency of the gyrotron. To date, a short pulse (SP) MDC prototype system has been manufactured and is currently under test. The long-term goal that makes the most sense is to use MDCs on 2-MW fusion gyrotrons in continuous wave (CW) operation. To achieve this, a CW MDC system based on the same physical principle as the SP system is designed and analyzed for the first time. The highlights of this design are the sweeping systems to keep the thermal loading within an acceptable limit when the MDC is operated in CW. In the present analysis, the expected performance and size of the new CW MDC design are compared with that of the SP MDC prototype and with the corresponding single-stage depressed collectors (SDCs) as a reference. In addition, the effects of thermal expansion in CW operation are analyzed and discussed.