Gustavo Martins

Dr. Gustavo Martins

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2022 in Analytica Chimica Acta
Verified
Journal Article
Closed access
GMGustavo Martins
Gustavo Martins
JGJeferson L. Gogola
Jeferson L. Gogola
LBLucas H. Budni
Lucas H. Budni
MPMaurício Alberto Poletti Papi
Maurício Alberto Poletti Papi
MBMaritza A.T. Bom
Maritza A.T. Bom
MBMarcio Fernando Bergamini
Marcio Fernando Bergamini

17 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
BBBeatriz Arnold Braz
Beatriz Arnold Braz
MHManuel Hospinal-Santiani
Manuel Hospinal-Santiani
GMGustavo Martins
Gustavo Martins
CPCristian S. Pinto
Cristian S. Pinto
AZAldo J. G. Zarbin
Aldo J. G. Zarbin
CSCarlos Ricardo Soccol
Carlos Ricardo Soccol
The development of immunosensors to detect antibodies or antigens has stood out in the face of traditional methods for diagnosing emerging diseases such as the one caused by the SARS-CoV-2 virus. The present study reports the construction of a simplified electrochemical immunosensor using a graphene-binding peptide applied as a recognition site to detect SARS-CoV-2 antibodies. A screen-printed electrode was used for sensor preparation by adding a solution of peptide and reduced graphene oxide (rGO). The peptide-rGO suspension was characterized by scanning electron microscopy (SEM), Raman spectroscopy, and Fourier transform infrared spectroscopy (FT-IR). The electrochemical characterization (electrochemical impedance spectroscopy—EIS, cyclic voltammetry—CV and differential pulse voltammetry—DPV) was performed on the modified electrode. The immunosensor response is based on the decrease in the faradaic signal of an electrochemical probe resulting from immunocomplex formation. Using the best set of experimental conditions, the analytic curve obtained showed a good linear regression (r2 = 0.913) and a limit of detection (LOD) of 0.77 μg mL−1 for antibody detection. The CV and EIS results proved the efficiency of device assembly. The high selectivity of the platform, which can be attributed to the peptide, was demonstrated by the decrease in the current percentage for samples with antibody against the SARS-CoV-2 S protein and the increase in the other antibodies tested. Additionally, the DPV measurements showed a clearly distinguishable response in assays against human serum samples, with sera with a response above 95% being considered negative, whereas responses below this value were considered positive. The diagnostic platform developed with specific peptides is promising and has the potential for application in the diagnosis of other infections that lead to high antibody titers.

10 February 2023 in Talanta
Verified
Journal Article
Closed access
BBBeatriz A. Braz
Beatriz A. Braz
MHManuel Hospinal-Santiani
Manuel Hospinal-Santiani
GMGustavo Martins
Gustavo Martins
JGJeferson L. Gogola
Jeferson L. Gogola
MVMarcia G.P. Valenga
Marcia G.P. Valenga
CSCarlos R. Soccol
Carlos R. Soccol

1 May 2025 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
LFLuís Marcos Cerdeira Ferreira
Luís Marcos Cerdeira Ferreira
GMGustavo Martins
Gustavo Martins
MPMaurício Alberto Poletti Papi
Maurício Alberto Poletti Papi
ASAnne Raquel Sotiles
Anne Raquel Sotiles
FWFernando Wypych
Fernando Wypych
LMLuiz Marcolino-Junior
Luiz Marcolino-Junior
Here, a carbon paste modified electrode (CPME) with Zn/Al-layered double hydroxide (Zn/Al-LDH) was developed for the simultaneous electrochemical detection of dopamine (DA) and uric acid (UA). The surface morphology and structural features of the synthesized Zn/Al-LDH were analyzed using scanning electron microscopy and X-ray diffraction analysis. The LDH-modified sensor exhibited enhanced adsorptive properties, significantly improving the preconcentration and detection of the targets. Electrochemical characterization using square wave voltammetry demonstrated that the Zn/Al-LDH structure plays a crucial role in increasing sensitivity due to its high surface area and favorable electrostatic interactions by adsorptive preconcentration separate from the electrochemical cell. Under optimized conditions (preconcentration pH of 6.0 and an electrochemical cell pH of 7.0), the sensor demonstrated excellent linearity across biologically relevant concentrations, ranging from 0.2 to 20 μM, in phosphate-buffered saline (PBS), synthetic urine, and synthetic cerebrospinal fluid, with limits of detection of 68 nM for UA and 71 nM for DA. Recovery studies confirmed the sensor’s reliability in complex biological matrices, with recoveries ranging from 90% to 120%. Compared to existing electrochemical sensors, the Zn/Al LDH-modified CPE offers a promising, selective, and efficient platform for neurotransmitter and metabolite analysis in biological samples.

1 November 2024 in Talanta
Verified
Journal Article
Closed access
BBBeatriz A. Braz
Beatriz A. Braz
MHManuel Hospinal-Santiani
Manuel Hospinal-Santiani
GMGustavo Martins
Gustavo Martins
AMAna P.Z. Moscardi
Ana P.Z. Moscardi
BBBreno C.B. Beirão
Breno C.B. Beirão
LMLuiz Marcolino-Junior
Luiz Marcolino-Junior

12 December 2025 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
TMThomas A.C. Martins
Thomas A.C. Martins
GMGustavo Martins
Gustavo Martins
MPMaurício A.P. Papi
Maurício A.P. Papi
LMLuiz Humberto Marcolino-Junior
Luiz Humberto Marcolino-Junior
MBMárcio F. Bergamini
Márcio F. Bergamini