Three-dimensional (3D) printed titanium orthopaedic implants have recently revolutionized the treatment of massive bone defects in the pelvis, and we are on the verge of a change from conventional to 3D printed manufacture for the mass production of millions of off-the-shelf (non-personalized) implants. The process of 3D printing has many adjustable variables, which taken together with the possible variation in designs that can be printed, has created even more possible variables in the final product that must be understood if we are to predict the performance and safety of 3D printed implants. We critically reviewed the clinical use of 3D printing in orthopaedics, focusing on cementless acetabular components used in total hip arthroplasty. We defined the clinical and engineering rationale of 3D printed acetabular cups, summarized the key variables involved in the manufacturing process that influence the properties of the final parts, together with the main limitations of this technology, and created a classification according to end-use application to help explain the controversial and topical issues. Whilst early clinical outcomes related to 3D printed cups have been promising, in-depth robust investigations are needed, partly because regulatory approval systems have not fully adapted to the change in technology. Analysis of both pristine and retrieved cups, together with long-term clinical outcomes, will help the transition to 3D printing to be managed safely.
Metal artifact reduction sequence (MARS) MRI and ultrasound scanning (USS) can both be used to detect pseudotumors, abductor muscle atrophy, and tendinous pathology in patients with painful metal-on-metal (MOM) hip arthroplasty. We wanted to determine the diagnostic test characteristics of USS using MARS MRI as a reference for detection of pseudotumors and muscle atrophy. PatienTS AND METHODS: We performed a prospective cohort study to compare MARS MRI and USS findings in 19 consecutive patients with unilateral MOM hips. Protocolized USS was performed by consultant musculoskeletal radiologists who were blinded regarding clinical details. Reports were independently compared with MARS MRI, the imaging gold standard, to calculate predictive values. The prevalence of pseudotumors on MARS MRI was 68% (95% CI: 43-87) and on USS it was 53% (CI: 29-76). The sensitivity of USS in detecting pseudotumors was 69% (CI 39-91) and the specificity was 83% (CI: 36-97). The sensitivity of detection of abductor muscle atrophy was 47% (CI: 24-71). In addition, joint effusion was detected in 10 cases by USS and none were seen by MARS MRI. We found a poor agreement between USS and MARS MRI. USS was inferior to MARS MRI for detection of pseudotumors and muscle atrophy, but it was superior for detection of joint effusion and tendinous pathologies. MARS MRI is more advantageous than USS for practical reasons, including preoperative planning and longitudinal comparison.
24 August 2023 in BMJ Open Sport & Exercise Medicine
Objectives This study aims to quantitatively evaluate whether there are muscle mass differences between male and female recreational cyclists and compare muscle quality and body composition in the pelvis region between two well-matched groups of fit and healthy male and female adults. Methods This cross-sectional study involved 45 female and 42 male recreational cyclists. The inclusion criteria for both groups were to have cycled more than 7000 km in the last year, have an absence of injuries and other health problems, have no contraindication to MRI, and be 30–65 years old. Our main outcome measures were fat fraction, as a measure of intramuscular fat (IMF) content, and volume of the gluteal muscles measured using Dixon MRI. The gluteal subcutaneous adipose tissue (SAT) volume was evaluated as a secondary measure. Results We found that there were no gender differences in the IMF content of gluteus maximus (GMAX, p=0.42), gluteus medius (GMED, p=0.69) and gluteus minimus (GMIN, p=0.06) muscles, despite women having more gluteal SAT (p<0.01). Men had larger gluteal muscles than women (p<0.01), but no differences were found when muscle volume was normalised by body weight (GMAX, p=0.54; GMED, p=0.14; GMIN, p=0.19). Conclusions Our study shows that despite the recognised hormonal differences between men and women, there is gender equivalence in the muscle mass and quality of the gluteal muscles when matched for exercise and body weight. This new MRI study provides key information to better understand gender similarities and differences in skeletal muscle and body composition.
Background: The management of massive acetabular defects at the time of revision hip surgery is challenging. Severe pelvic bone loss and the heterogeneity and quality of the remaining bone stock can compromise the fixation and mechanical stability of the implant. Methods: We reviewed a database of consecutive patients who had undergone acetabular reconstruction with the use of a custom 3D-printed implant with a dual-mobility bearing for the treatment of Paprosky type-3B defects between 2016 and 2019. Functional and radiological outcomes were assessed. Results: A total of 26 patients (17 women and 9 men) with a minimum follow-up of 36 months (median, 53 months; range, 36 to 77 months) were identified. The median age at surgery was 69 years (range, 49 to 90 years), and 4 patients had pelvic discontinuity. The cumulative implant survivorship was 100%. The median Oxford Hip Score improved significantly from 8 (range, 2 to 21) preoperatively to 32 (range, 14 to 47) postoperatively (p = 0.0001). One patient had a transient sciatic nerve palsy, 1 hip dislocated 6 months postoperatively and was managed nonoperatively, and 1 infection recurred. No patient had a fracture. Radiographic evaluation showed bone ingrowth at the bone-implant interface in 24 patients (92%) at ≥12 months of follow-up and showed no evidence of implant loosening or migration at the latest follow-up (3 to 6 years). Conclusions: Excellent functional improvement, implant survivorship, and osseointegration were recorded in the patient cohort. Accurate preoperative planning and the adoption of custom 3D-printed implants showed promising results in complex revision hip surgery. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
We aimed to assess polyethylene liners of retrieved hips of one design of a dual mobility (DM) cup liner and two designs of femoral stems to better understand the role of femoral stem design on polyethylene impingement.
Background: Modern designs of joint replacements require a large inventory of components to be available during surgery. Pre-operative CT imaging aids 3D surgical planning and implant sizing, which should reduce the inventory size and enhance clinical outcome. We aimed to better understand the impact of the use of 3D surgical planning and Patient Specific Instrumentation (PSI) on hip implant inventory. Methods: An initial feasibility study of 25 consecutive cases was undertaken to assess the discrepancy between the planned component sizes and those implanted to determine whether it was possible to reduce the inventory for future cases. Following this, we performed a pilot study to investigate the effect of an optimized inventory stock on the surgical outcome: we compared a group of 20 consecutive cases (experimental) with the 25 cases in the feasibility study (control). We assessed: (1) accuracy of the 3D planning system in predicting size (%); (2) inventory size changes (%); (3) intra and post-operative complications. Results: The feasibility study showed variability within 1 size range, enabling us to safely optimize inventory stock for the pilot study. (1) 3D surgical planning correctly predicted sizes in 93% of the femoral and 89% of the acetabular cup components; (2) there was a 61% reduction in the implant inventory size; (3) we recorded good surgical outcomes with no difference between the 2 groups, and all patients had appropriately sized implants. Conclusions: 3D planning is accurate in up to 95% of the cases. CT-based planning can reduce inventory size in the hospital setting potentially leading to a reduction in costs.