Martin Belzunce

Dr. Martin Belzunce

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2017 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
AMAbolfazl Mehranian
Abolfazl Mehranian
MBMartin Belzunce
Martin Belzunce
FNFlavia Niccolini
Flavia Niccolini
MPMarios Politis
Marios Politis
CPClaudia Prieto
Claudia Prieto
ARAndrew J Reader
Andrew J Reader
In this study, we investigate the application of multi-parametric anato-functional (MR-PET) priors for the maximum a posteriori (MAP) reconstruction of brain PET data in order to address the limitations of the conventional anatomical priors in the presence of PET-MR mismatches. In addition to partial volume correction benefits, the suitability of these priors for reconstruction of low-count PET data is also introduced and demonstrated, comparing to standard maximum-likelihood (ML) reconstruction of high-count data. The conventional local Tikhonov and total variation (TV) priors and current state-of-the-art anatomical priors including the Kaipio, non-local Tikhonov prior with Bowsher and Gaussian similarity kernels are investigated and presented in a unified framework. The Gaussian kernels are calculated using both voxel- and patch-based feature vectors. To cope with PET and MR mismatches, the Bowsher and Gaussian priors are extended to multi-parametric priors. In addition, we propose a modified joint Burg entropy prior that by definition exploits all parametric information in the MAP reconstruction of PET data. The performance of the priors was extensively evaluated using 3D simulations and two clinical brain datasets of [18F]florbetaben and [18F]FDG radiotracers. For simulations, several anato-functional mismatches were intentionally introduced between the PET and MR images, and furthermore, for the FDG clinical dataset, two PET-unique active tumours were embedded in the PET data. Our simulation results showed that the joint Burg entropy prior far outperformed the conventional anatomical priors in terms of preserving PET unique lesions, while still reconstructing functional boundaries with corresponding MR boundaries. In addition, the multi-parametric extension of the Gaussian and Bowsher priors led to enhanced preservation of edge and PET unique features and also an improved bias-variance performance. In agreement with the simulation results, the clinical results also showed that the Gaussian prior with voxel-based feature vectors, the Bowsher and the joint Burg entropy priors were the best performing priors. However, for the FDG dataset with simulated tumours, the TV and proposed priors were capable of preserving the PET-unique tumours. Finally, an important outcome was the demonstration that the MAP reconstruction of a low-count FDG PET dataset using the proposed joint entropy prior can lead to comparable image quality to a conventional ML reconstruction with up to 5 times more counts. In conclusion, multi-parametric anato-functional priors provide a solution to address the pitfalls of the conventional priors and are therefore likely to increase the diagnostic confidence in MR-guided PET image reconstructions.

9 November 2017 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
JBJames Bland
James Bland
AMAbolfazl Mehranian
Abolfazl Mehranian
MBMartin Belzunce
Martin Belzunce
SESam Ellis
Sam Ellis
CMColm J. McGinnity
Colm J. McGinnity
ARAndrew J. Reader
Andrew J. Reader
Positron emission tomography (PET) image reconstruction is highly susceptible to the impact of Poisson noise, and if shorter acquisition times or reduced injected doses are used, the noisy PET data become even more limiting. The recent development of kernel expectation maximization is a simple way to reduce noise in PET images, and we show in this paper that impressive dose reduction can be achieved when the kernel method is used with MR-derived kernels. The kernel method is shown to surpass maximum likelihood expectation maximization (MLEM) for the reconstruction of low-count datasets (corresponding to those obtained at reduced injected doses) producing visibly clearer reconstructions for unsmoothed and smoothed images, at all count levels. The kernel EM reconstruction of 10% of the data had comparable whole brain voxel-level error measures to the MLEM reconstruction of 100% of the data (for simulated data, at 100 iterations). For regional metrics, the kernel method at reduced dose levels attained a reduced coefficient of variation and more accurate mean values compared to MLEM. However, the advances provided by the kernel method are at the expense of possible over-smoothing of features unique to the PET data. Further assessment on clinical data is required to determine the level of dose reduction that can be routinely achieved using the kernel method, whilst maintaining the diagnostic utility of the scan.

18 April 2017 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
AMAbolfazl Mehranian
Abolfazl Mehranian
MBMartin Belzunce
Martin Belzunce
CPClaudia Prieto
Claudia Prieto
AHAlexander Hammers
Alexander Hammers
ARAndrew J. Reader
Andrew J. Reader
In this paper, we propose a generalized joint sparsity regularization prior and reconstruction framework for the synergistic reconstruction of positron emission tomography (PET) and under sampled sensitivity encoded magnetic resonance imaging data with the aim of improving image quality beyond that obtained through conventional independent reconstructions. The proposed prior improves upon the joint total variation (TV) using a non-convex potential function that assigns a relatively lower penalty for the PET and MR gradients, whose magnitudes are jointly large, thus permitting the preservation and formation of common boundaries irrespective of their relative orientation. The alternating direction method of multipliers (ADMM) optimization framework was exploited for the joint PET-MR image reconstruction. In this framework, the joint maximum a posteriori objective function was effectively optimized by alternating between well-established regularized PET and MR image reconstructions. Moreover, the dependency of the joint prior on the PET and MR signal intensities was addressed by a novel alternating scaling of the distribution of the gradient vectors. The proposed prior was compared with the separate TV and joint TV regularization methods using extensive simulation and real clinical data. In addition, the proposed joint prior was compared with the recently proposed linear parallel level sets (PLSs) method using a benchmark simulation data set. Our simulation and clinical data results demonstrated the improved quality of the synergistically reconstructed PET-MR images compared with the unregularized and conventional separately regularized methods. It was also found that the proposed prior can outperform both the joint TV and linear PLS regularization methods in assisting edge preservation and recovery of details, which are otherwise impaired by noise and aliasing artifacts. In conclusion, the proposed joint sparsity regularization within the presented a ADMM reconstruction framework is a promising technique, nonetheless our clinical results showed that the clinical applicability of joint reconstruction might be limited in current PET-MR scanners, mainly due to the lower resolution of PET images.

13 February 2020 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
MBMartin Belzunce
Martin Belzunce
JHJohann Henckel
Johann Henckel
ALAnna Di Laura
Anna Di Laura
AHAlister Hart
Alister Hart

8 September 2019 in Medical Physics
Verified
Journal Article
Open access
PDF file
JBJames Bland
James Bland
AMAbolfazl Mehranian
Abolfazl Mehranian
MBMartin Belzunce
Martin Belzunce
SESam Ellis
Sam Ellis
CCCasper da Costa‐Luis
Casper da Costa‐Luis
ARAndrew J. Reader
Andrew J. Reader
Purpose: Numerous image reconstruction methodologies for positron emission tomography (PET) have been developed that incorporate magnetic resonance (MR) imaging structural information, producing reconstructed images with improved suppression of noise and reduced partial volume effects. However, the influence of MR structural information also increases the possibility of suppression or bias of structures present only in the PET data (PET‐unique regions). To address this, further developments for MR‐informed methods have been proposed, for example, through inclusion of the current reconstructed PET image, alongside the MR image, in the iterative reconstruction process. In this present work, a number of kernel and maximuma posteriori(MAP) methodologies are compared, with the aim of identifying methods that enable a favorable trade‐off between the suppression of noise and the retention of unique features present in the PET data.Methods: The reconstruction methods investigated were: the MR‐informed conventional and spatially compact kernel methods, referred to as KEM and KEM largest value sparsification (LVS) respectively; the MR‐informed Bowsher and Gaussian MR‐guided MAP methods; and the PET‐MR‐informed hybrid kernel and anato‐functional MAP methods. The trade‐off between improving the reconstruction of the whole brain region and the PET‐unique regions was investigated for all methods in comparison with postsmoothed maximum likelihood expectation maximization (MLEM), evaluated in terms of structural similarity index (SSIM), normalized root mean square error (NRMSE), bias, and standard deviation. Both simulated BrainWeb (10 noise realizations) and real [18F] fluorodeoxyglucose (FDG) three‐dimensional datasets were used. The real [18F]FDG dataset was augmented with simulated tumors to allow comparison of the reconstruction methodologies for the case of known regions of PET‐MR discrepancy and evaluated at full counts (100%) and at a reduced (10%) count level.Results: For the high‐count simulated and real data studies, the anato‐functional MAP method performed better than the other methods under investigation (MR‐informed, PET‐MR‐informed and postsmoothed MLEM), in terms of achieving the best trade‐off for the reconstruction of the whole brain and PET‐unique regions, assessed in terms of the SSIM, NRMSE, and bias vs standard deviation. The inclusion of PET information in the anato‐functional MAP method enables the reconstruction of PET‐unique regions to attain similarly low levels of bias as unsmoothed MLEM, while moderately improving the whole brain image quality for low levels of regularization. However, for low count simulated datasets the anato‐functional MAP method performs poorly, due to the inclusion of noisy PET information in the regularization term. For the low counts simulated dataset, KEM LVS and to a lesser extent, HKEM performed better than the other methods under investigation in terms of achieving the best trade‐off for the reconstruction of the whole brain and PET‐unique regions, assessed in terms of the SSIM, NRMSE, and bias vs standard deviation.Conclusion: For the reconstruction of noisy data, multiple MR‐informed methods produce favorable whole brain vs PET‐unique region trade‐off in terms of the image quality metrics of SSIM and NRMSE, comfortably outperforming the whole image denoising of postsmoothed MLEM.

24 August 2023 in BMJ Open Sport & Exercise Medicine
Verified
Journal Article
Open access
PDF file
MBMartin Belzunce
Martin Belzunce
JHJohann Henckel
Johann Henckel
ALAnna Di Laura
Anna Di Laura
LHLaura Maria Horga
Laura Maria Horga
AHAlister James Hart
Alister James Hart
Objectives This study aims to quantitatively evaluate whether there are muscle mass differences between male and female recreational cyclists and compare muscle quality and body composition in the pelvis region between two well-matched groups of fit and healthy male and female adults. Methods This cross-sectional study involved 45 female and 42 male recreational cyclists. The inclusion criteria for both groups were to have cycled more than 7000 km in the last year, have an absence of injuries and other health problems, have no contraindication to MRI, and be 30–65 years old. Our main outcome measures were fat fraction, as a measure of intramuscular fat (IMF) content, and volume of the gluteal muscles measured using Dixon MRI. The gluteal subcutaneous adipose tissue (SAT) volume was evaluated as a secondary measure. Results We found that there were no gender differences in the IMF content of gluteus maximus (GMAX, p=0.42), gluteus medius (GMED, p=0.69) and gluteus minimus (GMIN, p=0.06) muscles, despite women having more gluteal SAT (p<0.01). Men had larger gluteal muscles than women (p<0.01), but no differences were found when muscle volume was normalised by body weight (GMAX, p=0.54; GMED, p=0.14; GMIN, p=0.19). Conclusions Our study shows that despite the recognised hormonal differences between men and women, there is gender equivalence in the muscle mass and quality of the gluteal muscles when matched for exercise and body weight. This new MRI study provides key information to better understand gender similarities and differences in skeletal muscle and body composition.