Max J Zinser

Max J Zinser

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Nourhan HassanNourhan Hassan
Nourhan Hassan
TKThomas Krieg
Thomas Krieg
MZMax J Zinser
Max J Zinser
KSKai Schröder
Kai Schröder
NKNadja Kröger
Nadja Kröger
The utilization of materials in medical implants, serving as substitutes for non-functional biological structures, supporting damaged tissues, or reinforcing active organs, holds significant importance in modern healthcare, positively impacting the quality of life for millions of individuals worldwide. However, certain implants may only be required temporarily to aid in the healing process of diseased or injured tissues and tissue expansion. Biodegradable metals, including zinc (Zn), magnesium (Mg), iron, and others, present a new paradigm in the realm of implant materials. Ongoing research focuses on developing optimized materials that meet medical standards, encompassing controllable corrosion rates, sustained mechanical stability, and favorable biocompatibility. Achieving these objectives involves refining alloy compositions and tailoring processing techniques to carefully control microstructures and mechanical properties. Among the materials under investigation, Mg- and Zn-based biodegradable materials and their alloys demonstrate the ability to provide necessary support during tissue regeneration while gradually degrading over time. Furthermore, as essential elements in the human body, Mg and Zn offer additional benefits, including promoting wound healing, facilitating cell growth, and participating in gene generation while interacting with various vital biological functions. This review provides an overview of the physiological function and significance for human health of Mg and Zn and their usage as implants in tissue regeneration using tissue scaffolds. The scaffold qualities, such as biodegradation, mechanical characteristics, and biocompatibility, are also discussed.

1 January 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
FWFranziska Wieja
Franziska Wieja
GJGeorg Jacobs
Georg Jacobs
SSSebastian Stein
Sebastian Stein
AKAlexander Kopp
Alexander Kopp
KGKerstin van Gaalen
Kerstin van Gaalen
MZMax J Zinser
Max J Zinser
Large segmental mandible bone defects still represent a challenge for endogenous regeneration. Despite the bone's capacity to heal in many clinical situations, bone defects over a critical size do not heal spontaneously. An emerging treatment of critically sized mandibular defects is the implantation of individually manufactured scaffolds consisting of biodegradable magnesium alloys. Biomedical engineers faced the challenge of developing a scaffold structure that not only provides sufficient stability, but also stimulates and promotes bone growth while considering the degradation of the magnesium alloy. The porosity of the scaffold must also support bone ingrowth and neovascularization. For an optimal design and subsequent structural optimization knowledge of external load cases is essential. However, currently the muscle and joint forces of the mandible cannot be measured directly. The aim of our study was therefore the development of a parametric human mandible model to determine the relevant boundary conditions for the subsequent structural optimization of individual jawbone implants. Using a model-based approach, determining the essential external load of the mandible as a function of the age and sex of a patient individually and the realistic simulation of the mechanical stress for patient-specific loads and anatomies has been realized. The developed model is successfully validated by evaluating the deformations and stresses of the lower jaw of a possible patient and comparing them with the results of dental research. Based on the results of the modelling, in a subsequent optimization process section forces at the interface between the bone tissue and jawbone implant can be determined and used to optimize the design of the jawbone implant.

28 December 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
MZMax J Zinser
Max J Zinser
NKNadja Kröger
Nadja Kröger
WMWolfram Malter
Wolfram Malter
TSTino Schulz
Tino Schulz
MPMichael Puesken
Michael Puesken
CHCarola Heneweer
Carola Heneweer
Deep inferior epigastric artery flaps (DIEP) represent the gold standard of autologous breast reconstruction. Due to significant variations in vascular anatomy, preoperative perforator mapping (PM) is mandatory in order to ensure the presence of a sufficient perforator within the flap. In this regard, CT angiography (CTA) is currently the method of choice. Therefore, we investigated the value of contrast-enhanced ultrasound (CEUS) techniques for preoperative PM in comparison to CTA. Patients underwent PM, utilizing both CTA and CEUS techniques. Documentation included the course of the vascular pedicle through the rectus muscle (M), fascial penetration (F), the subcutaneous plexus (P) and the skin point (SP) on either side of the abdomen. Thus, contrast-enhanced B-Flow (BCEUS), B-Flow ultrasound (BUS), CEUS, color Doppler ultrasound (CDUS) and CTA were evaluated in terms of the diagnostic consistency and effectiveness of PM. Precision (∆L) was then calculated in relation to the actual intraoperative location. Statistical analysis included Kruskall–Wallis, Levene and Bonferroni tests, as well as Spearman correlations. A total of 39 DIEP flaps were analyzed. Only CTA (∆L = 2.85 mm) and BCEUS (∆L = 4.57 mm) enabled complete PM, also including P and SP, whereas CDUS, CEUS and BUS enabled clear PM throughout M and F only. Regarding the number of detected perforators, PM techniques are ranked from high to low as follows: CTA, BCEUS, BUS, CEUS and CDUS. CTA and BCEUS showed sufficient diagnostic consistency for SP, P and F, while CDUS and CTA had a superior performance for M. BCEUS offers precise image-controlled surface tags and dynamic information for PM without imposing radiation and may, therefore, be considered a feasible add-on or alternative to CTA. However, BCEUS requires an experienced examiner and is more time-consuming.

1 May 2021 in Plastic and Reconstructive Surgery - Global Open
Verified
Journal Article
Open access
CHCarola Heneweer
Carola Heneweer
MZMatthias Md Zirk
Matthias Md Zirk
ASAli Md Safi
Ali Md Safi
RSRalf Md Smeets
Ralf Md Smeets
WMWolfram Malter
Wolfram Malter
MZMax J Zinser
Max J Zinser
Precise perforator mapping of the epifascial and subcutaneous course of the perforator flaps, including the precise detection of the skin point, is mandatory for successful preoperative flap design and planning of supramicrosurgery. We investigated the effectiveness of contrast-enhanced B-flow (BCEUS) imaging for perforator mapping and preoperative perforator flap planning and compared it with B-flow ultrasound, contrast-enhanced ultrasound, and color Doppler ultrasound. Sixteen patients who received an individualized perforator flap reconstruction were included in the study. Preoperative perforator mapping includes the following structures: subfascial course of the pedicle, fascial penetration point, subcutaneous course (epifascial and subcutaneous), and perforator skin point. The precision of the preoperative perforator mapping was analyzed for color Doppler ultrasound, contrast-enhanced ultrasound, B-flow ultrasound, and BCEUS. Each technique was able to precisely display the subfascial course of the vascular pedicle, including the fascial penetration point. However, only BCEUS enabled precise mapping of the epifascial and subcutaneous (suprafascial) course, including the skin point of the perforators with a clear delineation. Precise knowledge of the suprafascial course of the perforators is mandatory for successful supermicrosurgery and perforator flap planning. BCEUS imaging facilitates full perforator mapping, which improves the safety of flap harvesting. However, BCEUS is technically demanding and requires an experienced sonographer.

1 May 2005 in International Congress Series
Verified
Journal Article
Closed access
RMR.A. Mischkowski
R.A. Mischkowski
MZMax J Zinser
Max J Zinser
AKA. Kübler
A. Kübler
USU. Seifert
U. Seifert
JZJ.E. Zöller
J.E. Zöller

Verified
Journal Article
Open access
PDF file
AKAlexander Kopp
Alexander Kopp
LSLaura Schunck
Laura Schunck
MGMartin Gosau
Martin Gosau
Ralf SmeetsRalf Smeets
Ralf Smeets
SBSimon Burg
Simon Burg
RRRico Rutkowski
Rico Rutkowski
In this study, we describe the manufacturing and characterization of silk fibroin membranes derived from the silkworm Bombyx mori. To date, the dissolution process used in this study has only been researched to a limited extent, although it entails various potential advantages, such as reduced expenses and the absence of toxic chemicals in comparison to other conventional techniques. Therefore, the aim of this study was to determine the influence of different fibroin concentrations on the process output and resulting membrane properties. Casted membranes were thus characterized with regard to their mechanical, structural and optical assets via tensile testing, SEM, light microscopy and spectrophotometry. Cytotoxicity was evaluated using BrdU, XTT, and LDH assays, followed by live–dead staining. The formic acid (FA) dissolution method was proven to be suitable for the manufacturing of transparent and mechanically stable membranes. The fibroin concentration affects both thickness and transparency of the membranes. The membranes did not exhibit any signs of cytotoxicity. When compared to other current scientific and technical benchmarks, the manufactured membranes displayed promising potential for various biomedical applications. Further research is nevertheless necessary to improve reproducible manufacturing, including a more uniform thickness, less impurity and physiological pH within the membranes.