Carola Heneweer

Dr. Carola Heneweer


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
MZMax J Zinser
Max J Zinser
NKNadja Kröger
Nadja Kröger
WMWolfram Malter
Wolfram Malter
TSTino Schulz
Tino Schulz
MPMichael Puesken
Michael Puesken
CHCarola Heneweer
Carola Heneweer
Deep inferior epigastric artery flaps (DIEP) represent the gold standard of autologous breast reconstruction. Due to significant variations in vascular anatomy, preoperative perforator mapping (PM) is mandatory in order to ensure the presence of a sufficient perforator within the flap. In this regard, CT angiography (CTA) is currently the method of choice. Therefore, we investigated the value of contrast-enhanced ultrasound (CEUS) techniques for preoperative PM in comparison to CTA. Patients underwent PM, utilizing both CTA and CEUS techniques. Documentation included the course of the vascular pedicle through the rectus muscle (M), fascial penetration (F), the subcutaneous plexus (P) and the skin point (SP) on either side of the abdomen. Thus, contrast-enhanced B-Flow (BCEUS), B-Flow ultrasound (BUS), CEUS, color Doppler ultrasound (CDUS) and CTA were evaluated in terms of the diagnostic consistency and effectiveness of PM. Precision (∆L) was then calculated in relation to the actual intraoperative location. Statistical analysis included Kruskall–Wallis, Levene and Bonferroni tests, as well as Spearman correlations. A total of 39 DIEP flaps were analyzed. Only CTA (∆L = 2.85 mm) and BCEUS (∆L = 4.57 mm) enabled complete PM, also including P and SP, whereas CDUS, CEUS and BUS enabled clear PM throughout M and F only. Regarding the number of detected perforators, PM techniques are ranked from high to low as follows: CTA, BCEUS, BUS, CEUS and CDUS. CTA and BCEUS showed sufficient diagnostic consistency for SP, P and F, while CDUS and CTA had a superior performance for M. BCEUS offers precise image-controlled surface tags and dynamic information for PM without imposing radiation and may, therefore, be considered a feasible add-on or alternative to CTA. However, BCEUS requires an experienced examiner and is more time-consuming.

24 March 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
AIAndra-Iza Iuga
Andra-Iza Iuga
HCHeike Carolus
Heike Carolus
LCLiliana Lourenco Caldeira
Liliana Lourenco Caldeira
JKJonathan Kottlors
Jonathan Kottlors
MRMiriam Rinneburger
Miriam Rinneburger
TPThorsten Persigehl
Thorsten Persigehl
Background/Objectives: Accurate and reproducible lymph node (LN) measurement is essential for oncologic staging and therapy monitoring but is subject to inter-reader variability. This study evaluated the accuracy and reproducibility of a fully automated artificial intelligence (AI)-based LN measurement workflow in contrast-enhanced chest CT, using multi-reader manual measurements as reference. Methods: Sixty thoracic LNs from seven patients were independently measured by 13 radiologists in two reading rounds. The median of all measurements served as the ground truth (GT). Automated short- and long-axis diameters were derived from fully automated 3D CNN-based segmentations. Agreement between AI and manual measurements was assessed using Friedman testing, intraclass correlation coefficients (ICCs), and concordance correlation coefficients (CCCs). Measurement stability was evaluated across repeated runs on different hardware systems. Results: A total of 2280 manual measurements were analyzed. Manual assessment showed significant inter-reader variability (p < 0.01), while intra-reader agreement was high. No significant differences were observed between AI-based measurements and the GT (all p > 0.01). Agreement was good, with CCC values of 0.86 (SAD) and 0.79 (LAD). AI-based measurements were numerically stable across hardware configurations. Conclusions: Fully automated AI-based LN measurements in chest CT scans provide strong agreement with multi-reader consensus and high numerical stability. Automated measurement may support more standardized and reproducible oncologic imaging assessment.