Tingting Zhao

Ms. Tingting Zhao

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2024 in Metabolites
Verified
Journal Article
Open access
PDF file
TZTingting Zhao
Tingting Zhao
YLYan Liang
Yan Liang
XZXiaolan Zhen
Xiaolan Zhen
HWHong Wang
Hong Wang
LSLi Song
Li Song
HLHui Li
Hui Li
Currently, the clinical cure rate for primary liver cancer remains low. Effective screening and early diagnosis of hepatocellular carcinoma (HCC) remain clinical challenges. Exosomes are intimately associated with tumor development and their contents have the potential to serve as highly sensitive tumor-specific markers. A comprehensive untargeted metabolomics study was conducted using exosome samples extracted from the serum of 48 subjects (36 HCC patients and 12 healthy controls) via a commercial kit. An ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) strategy was used to identify the metabolic compounds. A total of 18 differential metabolites were identified using the non-targeted metabolomics approach of UPLC-QTOF-MS/MS. Pathway analysis revealed significant alterations in the arachidonic acid metabolism, linoleic acid metabolism, and unsaturated fatty acid metabolism pathways. ROC analysis indicated that three metabolites with AUC values exceeding 0.900 were selected as potential biomarkers: caprylic acid and linoleic acid were upregulated in the HCC group, whereas pentadecanoic acid was downregulated. Linoleic acid, caprylic acid, and pentadecanoic acid are potential biomarkers for diagnosing HCC. The significant alterations in these three metabolic pathways offer new insights into the mechanisms underlying HCC formation and progression.

9 January 2023 in Molecules
Verified
Journal Article
Open access
PDF file
TZTingting Zhao
Tingting Zhao
WJWen Jiang
Wen Jiang
XZXiaolan Zhen
Xiaolan Zhen
CJchengcheng jin
chengcheng jin
YZYifan Zhang
Yifan Zhang
HLHui Li
Hui Li
Here, a QuEChERS (quick, easy, cheap, effective, rugged, and safe) pretreatment method was combined with UPLC-MS/MS to facilitate the rapid and reliable simultaneous detection of five calcium channel blockers (CCBs) in human plasma. For this approach, samples were treated with 1 mL of acetonitrile, 350 mg of magnesium sulfate, and 70 mg of PSA adsorbent prior to centrifugation. Supernatants then underwent gradient elution for 8 min with an Agilent C18 column using an acetonitrile-water solution supplemented with 5 mmol⋅L−1 of ammonium acetate. This technique exhibited a good linear response in the 1–800 ng⋅mL−1 range for the analyzed drugs, with an R2≥ 0.9921, an accuracy of 87.54–113.05%, a matrix effect (ME) of 91.21–116.39%, a precision of 0.19–11.64%, and stability of no more than 10.05%. This time-saving QuEChERS reagent-based pretreatment technique thus allowed for the simultaneous and accurate detection of five CCBs in human plasma samples, providing a promising new basis for therapeutic drug monitoring in patients with hypertension.

24 November 2023 in Heliyon
Verified
Journal Article
Open access
CJchengcheng jin
chengcheng jin
TWTing Wang
Ting Wang
TZTingting Zhao
Tingting Zhao
WJWen Jiang
Wen Jiang
XZXiaolan Zhen
Xiaolan Zhen
HLHui Li
Hui Li
To determine the concentrations of nine drugs used in the treatment of cardiovascular diseases in human plasma through QuEChERS pre-treatment combined with ultra-performance liquid chromatography-tandem mass spectrometry. Plasma samples were extracted with 3 mL of acetonitrile, 400 mg of anhydrous magnesium sulfate as a salting agent, and 20 mg of C18 as a sorbent. An Agilent Poroshell 120 EC-C18 column (4.6 × 100 mm, 2.7 μm) was selected and methanol-0.1 % water was used as the mobile phase, and ESI positive ion detection mode was selected. Results: The plasma concentrations of nisoldipine, metoprolol, and prazosin exhibited good linearity within the range of 0.05–4.0 ng/mL (r > 0.99), while atenolol, bisoprolol, propranolol, rosuvastatin, and atorvastatin showed linearity within the range of 0.5–40 ng/mL (r > 0.99). Fluvastatin showed good linearity within the range of 5.0–400 ng/mL. The accuracy of the method ranged from 94.15 to 110.62 %, while the recovery levels were in the range of 85.23 %–115.13 %. The matrix effects were observed between-6.54 % and 12.43 %. The intra-day and inter-day RSD was <15 % for the three concentrations of low, medium, and high. Conclusion The proposed method is rapid, accurate, specific, simple, reproducible, and suitable for the simultaneous measurement of the concentrations of nine drugs used in the treatment of cardiovascular diseases in human plasma.