This paper proposes a novel method to reliably calibrate a pair of sensorized insoles utilizing an array of capacitive tactile pixels (taxels). A new calibration setup is introduced that is scalable and suitable for multiple kinds of wearable sensors and a procedure for the simultaneous calibration of each of the sensors in the insoles is presented. The calibration relies on a two-step optimization algorithm that, firstly, enables determination of a relevant set of mathematical models based on the instantaneous measurement of the taxels alone, and, then, expands these models to include the relevant portion of the time history of the system. By comparing the resulting models with our previous work on the same hardware, we demonstrate the effectiveness of the novel method both in terms of increased ability to cope with the non-linear characteristics of the sensors and increased pressure ranges achieved during the experiments performed.
(1) Background: Technological advancements provide new opportunities to objectively assess motor deficits in people with Multiple Sclerosis (PwMS). This pilot study aimed to evaluate the performance and usability of iFeel, a novel wearable system which integrates inertial sensors, instrumented shoes, and an AI-based algorithm. (2) Methods: Sixteen adult PwMS (Expanded Disability Status Scale—EDSS ≤ 6) performed motor tests (Timed 25-Foot Walk—T25FW; Timed Up and Go—TUG) both with and without the iFeel suit. Patient-reported outcomes (PROs) were also collected to assess perceived fatigue, dual-task impact, and walking difficulties. System Usability Scale (SUS) and ad hoc questionnaires have been further administered to test usability. (3) Results: No significant differences were found between the clinician and system-based scores for both T25FW (p = 0.383) and TUG (p = 0.447). Reliability analyses showed good agreement for T25FW (Intraclass Correlation Coefficient—ICC = 0.83) and excellent agreement for TUG (ICC = 0.92). Sensor-derived measures correlated strongly with PROs on fatigue, dual-task interference, and mobility. Usability was rated high (SUS: 78.6 ± 16.1), with participants reporting minimal discomfort and positive perceptions of iFeel usefulness for rehabilitation, health monitoring, and daily activities. (4) Conclusions: This pilot study provides preliminary yet promising evidence on the feasibility, usability, and perceived usefulness of the iFeel technology for motor assessment in PwMS. The findings support its further development and potential integration into clinical practice, particularly for remote or continuous motor monitoring.