Huihui Yu

Huihui Yu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
LJLongsheng Jin
Longsheng Jin
WLWeishuai Liu
Weishuai Liu
ZXZiying Xiao
Ziying Xiao
HYHaijian Yang
Haijian Yang
HYHuihui Yu
Huihui Yu
Meisheng WuMeisheng Wu
Meisheng Wu
Rapid and efficient detection of mycotoxins is of great significance in the field of food safety. In this review, several traditional and commercial detection methods are introduced, such as high-performance liquid chromatography (HPLC), liquid chromatography/mass spectrometry (LC/MS), enzyme-linked immunosorbent assay (ELISA), test strips, etc. Electrochemiluminescence (ECL) biosensors have the advantages of high sensitivity and specificity. The use of ECL biosensors for mycotoxins detection has attracted great attention. According to the recognition mechanisms, ECL biosensors are mainly divided into antibody-based, aptamer-based, and molecular imprinting techniques. In this review, we focus on the recent effects towards the designation of diverse ECL biosensors in mycotoxins assay, mainly including their amplification strategies and working mechanism.

12 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
LJLongsheng Jin
Longsheng Jin
HYHuihui Yu
Huihui Yu
WLWeishuai Liu
Weishuai Liu
ZXZiying Xiao
Ziying Xiao
HYHaijian Yang
Haijian Yang
Meisheng WuMeisheng Wu
Meisheng Wu
Fumonisin B1 (FB1) is a toxin produced by the metabolism of Fusarium oxysporum, which can cause serious effects on the nervous, respiratory, digestive, and reproductive systems of humans or animals; it is known as one of the highly toxic epidemic contaminants. Herein, we report the visual inspection of FB1 using bipolar electrodes (BPEs) with an array-based electrochemiluminescence (ECL) platform. The sensor consists of a PDMS cover and a glass substrate containing an array of 10 ITO electrodes. A specific sensing interface was constructed on the cathode of the BPE, which could modulate the ECL reactions that occurred at the anode of BPEs. To amplify the ECL signal, methylene blue (MB)-encapsulated Zr-MOFs (MB@Zr-MOFs) were synthesized and immobilized on the cathode of the BPE, which could amplify the ECL signal at the anode. By coupling the cyclic amplification effect of the DNA walker and nicking endonuclease (Nb.BbvCI), the biosensor can realize the visual measurement of FB1 in the range of 5 × 10−5~0.5 ng/mL. In addition, the developed biosensor was used to monitor the concentration of FB1 in maize and peanut samples. The recoveries were in the range of 99.2%~110.6%, which demonstrated the good accuracy of the designed BPE-ECL biosensor for FB1 assay in food samples.

19 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
DZDaoyuan Zhao
Daoyuan Zhao
YLYujing LIU
Yujing LIU
HJHong Jiang
Hong Jiang
HYHaijian Yang
Haijian Yang
HYHuihui Yu
Huihui Yu
Meisheng WuMeisheng Wu
Meisheng Wu
Au particles are commonly used for deposition on the surface of a bipolar electrode (BPE) in order to amplify electrochemical and electrochemiluminescence (ECL) signal because of their excellent conductivity, biocompatibility, and large surface area. In this work, a closed BPE device was fabricated and Au particles were deposited on the two poles of a BPE via bipolar deposition. Results indicated that the electrochemical stability of Au film on the anode part of the BPE and the reduction of AuCl4– to Au on the cathode part of the BPE depended on the conductivity of the solution. The prepared Au–Au BPE exhibited a remarkable amplification effect on the ECL signal. Then, a specific sensing interface was constructed on one pole of the BPE for the visual detection of prostate-specific antigens (PSA) based on sandwich-type immunoreactions between primary PSA antibodies (Ab1) on the electrode surface, PSA, and SiO2 nanoparticles labeled secondary PSA antibodies (SiO2-Ab2). The designed biosensor exhibited a good linear relationship for the ECL detection of PSA in the range of 1 × 10−6 to 1 × 10−10 g/mL with a correlation coefficient of 0.9866; the limit of detection (LOD) was 1.5 × 10−11 g/mL. Additionally, the biosensor can realize the electrochemical imaging of PSA by regulating the electrochemical oxidation of the Au anode with the immunoreactions on the cathode part of BPE. Therefore, the small, portable and highly sensitive biosensors have great potential for on-site detection.