Andreas Benjamin Schmidt

Dr. Andreas Benjamin Schmidt

1. German Cancer Consortium (DKTK), Partner Site Freiburg, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
+1

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2023 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
HMHenri de Maissin
Henri de Maissin
PGPhilipp R. Groß
Philipp R. Groß
OMObaid Mohiuddin
Obaid Mohiuddin
MWMoritz Weigt
Moritz Weigt
LNLuca Nagel
Luca Nagel
ASAndreas Benjamin Schmidt
Andreas Benjamin Schmidt
Metabolic magnetic resonance imaging (MRI) using hyperpolarized (HP) pyruvate is becoming a non‐invasive technique for diagnosing, staging, and monitoring response to treatment in cancer and other diseases. The clinically established method for producing HP pyruvate, dissolution dynamic nuclear polarization, however, is rather complex and slow. Signal Amplification By Reversible Exchange (SABRE) is an ultra‐fast and low‐cost method based on fast chemical exchange. Here, for the first time, we demonstrate not only in vivo utility, but also metabolic MRI with SABRE. We present a novel routine to produce aqueous HP [1‐13C]pyruvate‐d3 for injection in 6 minutes. The injected solution was sterile, non‐toxic, pH neutral and contained ≈30 mM [1‐13C]pyruvate‐d3 polarized to ≈11 % (residual 250 mM methanol and 20 μM catalyst). It was obtained by rapid solvent evaporation and metal filtering, which we detail in this manuscript. This achievement makes HP pyruvate MRI available to a wide biomedical community for fast metabolic imaging of living organisms.

1 January 2022 in Analytical Chemistry
Verified
Journal Article
Closed access
ASAndreas Benjamin Schmidt
Andreas Benjamin Schmidt
CBC. Russell Bowers
C. Russell Bowers
KBKai Buckenmaier
Kai Buckenmaier
ECEduard Y Chekmenev
Eduard Y Chekmenev
HMHenri de Maissin
Henri de Maissin
JHJan-Bernd Hövener
Jan-Bernd Hövener

6 March 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
ASAndreas Benjamin Schmidt
Andreas Benjamin Schmidt
SBS. Berner
S. Berner
WSW. Schimpf
W. Schimpf
CMC. Müller
C. Müller
TLT. Lickert
T. Lickert
JHJ. -B. Hövener
J. -B. Hövener
Hyperpolarized (HP) tracers dramatically increase the sensitivity of magnetic resonance imaging (MRI) to monitor metabolism non-invasively and in vivo. Their production, however, requires an extra polarizing device (polarizer) whose complexity, operation and cost can exceed that of an MRI system itself. Furthermore, the lifetime of HP tracers is short and some of the enhancement is lost during transfer to the application site. Here, we present the production of HP tracers in water without an external polarizer: by Synthesis Amid the Magnet Bore, A Dramatically Enhanced Nuclear Alignment (SAMBADENA) is achieved within seconds, corresponding to a hyperpolarization of ∼20%. As transfer of the tracer is no longer required, SAMBADENA may permit a higher polarization at the time of detection at a fraction of the cost and complexity of external polarizers. This development is particularly promising in light of the recently extended portfolio of biomedically relevant para-hydrogen-tracers and may lead to new diagnostic applications.

2 June 2023 in The Journal of Physical Chemistry Letters
Verified
Journal Article
Closed access
ASAndreas Benjamin Schmidt
Andreas Benjamin Schmidt
JEJames Eills
James Eills
LDLaurynas Dagys
Laurynas Dagys
MGMartin Gierse
Martin Gierse
MKMichael Keim
Michael Keim
SKStephan Knecht
Stephan Knecht

15 November 2022 in ACS Sensors
Verified
Journal Article
Closed access
ASAndreas Benjamin Schmidt
Andreas Benjamin Schmidt
HMHenri de Maissin
Henri de Maissin
IAIsaiah Adelabu
Isaiah Adelabu
SNShiraz Nantogma
Shiraz Nantogma
JEJessica Ettedgui
Jessica Ettedgui
ECEduard Y Chekmenev
Eduard Y Chekmenev

12 July 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ASAndreas Benjamin Schmidt
Andreas Benjamin Schmidt
SBStephan Berner
Stephan Berner
MBMoritz Braig
Moritz Braig
MZMirko Zimmermann
Mirko Zimmermann
JHJürgen Hennig
Jürgen Hennig
JHJan-Bernd Hövener
Jan-Bernd Hövener
Magnetic Resonance Imaging (MRI) is a powerful imaging tool but suffers from a low sensitivity that severely limits its use for detecting metabolism in vivo. Hyperpolarization (HP) methods have demonstrated MRI signal enhancement by several orders of magnitude, enabling the detection of metabolism with a sensitivity that was hitherto inaccessible. While it holds great promise, HP is typically relatively slow (hours), expensive (million $, €) and requires a dedicated device (“polarizer”). Recently, we introduced a new method that creates HP tracers without an external polarizer but within the MR-system itself based on parahydrogen induced polarization (PHIP): Synthesis Amid the Magnet Bore Allows Dramatically Enhanced Nuclear Alignment (SAMBADENA). To date, this method is the simplest and least cost-intensive method for hyperpolarized 13C-MRI. HP of P13C > 20% was demonstrated for 5mM tracer solutions previously. Here, we present a setup and procedure that enabled the first in vivo application of SAMBADENA: Within seconds, a hyperpolarized angiography tracer was produced and injected into an adult mouse. Subsequently, fast 13C-MRI was acquired which exhibited the vena cava, aorta and femoral arteries of the rodent. This first SAMBADENA in vivo 13C-angiography demonstrates the potential of the method as a fast, simple, low-cost alternative to produce HP-tracers to unlock the vast but hidden powers of MRI.