Moritz Weigt

Moritz Weigt

Auto-generated profile, based on publicly available information

Moritz Weigt

University Medical Center Freiburg

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2023 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
HMHenri de Maissin
Henri de Maissin
PGPhilipp R. Groß
Philipp R. Groß
OMObaid Mohiuddin
Obaid Mohiuddin
MWMoritz Weigt
Moritz Weigt
LNLuca Nagel
Luca Nagel
ASAndreas Benjamin Schmidt
Andreas Benjamin Schmidt
Metabolic magnetic resonance imaging (MRI) using hyperpolarized (HP) pyruvate is becoming a non‐invasive technique for diagnosing, staging, and monitoring response to treatment in cancer and other diseases. The clinically established method for producing HP pyruvate, dissolution dynamic nuclear polarization, however, is rather complex and slow. Signal Amplification By Reversible Exchange (SABRE) is an ultra‐fast and low‐cost method based on fast chemical exchange. Here, for the first time, we demonstrate not only in vivo utility, but also metabolic MRI with SABRE. We present a novel routine to produce aqueous HP [1‐13C]pyruvate‐d3 for injection in 6 minutes. The injected solution was sterile, non‐toxic, pH neutral and contained ≈30 mM [1‐13C]pyruvate‐d3 polarized to ≈11 % (residual 250 mM methanol and 20 μM catalyst). It was obtained by rapid solvent evaporation and metal filtering, which we detail in this manuscript. This achievement makes HP pyruvate MRI available to a wide biomedical community for fast metabolic imaging of living organisms.

25 July 2023 in Angewandte Chemie
Verified
Journal Article
Open access
HMHenri de Maissin
Henri de Maissin
PGPhilipp R. Groß
Philipp R. Groß
OMObaid Mohiuddin
Obaid Mohiuddin
MWMoritz Weigt
Moritz Weigt
LNLuca Nagel
Luca Nagel
ASAndreas Benjamin Schmidt
Andreas Benjamin Schmidt
Die metabolische Magnetresonanztomographie (MRT) mit hyperpolarisiertem (HP) Pyruvat wird zu einer vielversprechenden, nicht‐invasiven Technik für die Diagnose, die Charakterisierung und die Überwachung bei Behandlung von Krebs, sowie bei anderen Erkrankungen. Die klinisch etablierte Methode zur Herstellung HP‐Pyruvats, die dynamische Kernpolarisation, ist jedoch ein komplexes und langwieriges Verfahren. Die Signalverstärkung durch reversiblen Austausch (SABRE) ist eine ultraschnelle und kostengünstige Methode, die auf einem schnellen chemischen Austausch beruht. Hier demonstrieren wir zum ersten Mal eine in vivo‐Anwendung, sowie auch metabolische MRT mit SABRE. Wir präsentieren eine neuartige Routine zur Herstellung von wässrigem HP‐[1‐13C]Pyruvat‐d3 innerhalb von sechs Minuten, zur Anwendung in lebenden Organismen. Die injizierte Lösung war steril, ungiftig, pH‐neutral und enthielt ≈30 mM [1‐13C]Pyruvat‐d3, polarisiert auf ≈11 % (Rückstände von 250 mM Methanol und 20 μM Katalysator). Es wurde durch schnelle Lösungsmittelverdampfung und Metallfiltrierung gewonnen, die wir in diesem Manuskript ausführlich beschreiben. Diese Ergebnisse machen die HP‐Pyruvat‐MRT für eine breite biomedizinische Gemeinschaft zur schnellen metabolischen Bildgebung von lebenden Organismen verfügbar.

1 August 2024 in ChemRxiv
Verified
Preprint
Open access
PDF file
SPStefan Petersen
Stefan Petersen
LNLuca Nagel
Luca Nagel
PGPhilipp Groß
Philipp Groß
RWRobert Willing
Robert Willing
LHLisa Heß Heß
Lisa Heß Heß
ASAndreas Benjamin Schmidt
Andreas Benjamin Schmidt
Metabolic MRI using hyperpolarized (HP) [1-13C]pyruvate is promising for diagnostic medicine, allowing the study of cancer metabolism and early detection of therapy response. However, a possible widespread and routine use requires high-throughput and user-friendly technologies to produce the hyperpolarized media. Recently, we introduced a fast (6 min) and cost-effective method using Spin-Lock Induced Crossing and Signal Amplification By Reversible Exchange (SLIC-SABRE) at µT fields and a rapid purification to produce biocompatible HP solutions of aqueous pyruvate. In this study, we used SLIC-SABRE to conduct in vivo tumor metabolic imaging in a transgenic breast cancer mouse model (MMTV-PyMT). In agreement with previous HP MRI cancer studies, an elevated lactate metabolism was found in tumors compared to healthy breast tissue, heart, and vasculature, as well as distinct metabolic profiles within different tumor compartments. These findings suggest a potential link between lactate-to-pyruvate ratios and the varying levels of tumor cell proliferation and apoptosis observed by histological analyses. Our results underscore the potential of SABRE to enhance the accessibility and throughput of HP MRI, thereby advancing cancer research and diagnostic oncology.

15 December 2023 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Open access
Martin Peter PichotkaMartin Peter Pichotka
Martin Peter Pichotka
MWMoritz Weigt
Moritz Weigt
MSMukesch J. Shah
Mukesch J. Shah
MRMaximilian Russe
Maximilian Russe
TSThomas Stein
Thomas Stein
MRMarco Reisert
Marco Reisert
Despite their life-saving capabilities, cerebrospinal fluid (CSF) shunts exhibit high failure rates, with a large fraction of failures attributed to the regulating valve. Due to a lack of methods for the detailed analysis of valve malfunctions, failure mechanisms are not well understood, and valves often have to be surgically explanted on the mere suspicion of malfunction. The presented pilot study aims to demonstrate radiological methods for comprehensive analysis of CSF shunt valves, considering both the potential for failure analysis in design optimization, and for future clinical in-vivo application to reduce the number of required shunt revision surgeries. The proposed method could also be utilized to develop and support in situ repair methods (e.g. by lysis or ultrasound) of malfunctioning CSF shunt valves. The primary methods described are contrast-enhanced radiographic time series of CSF shunt valves, taken in a favorable projection geometry at low radiation dose, and the machine-learning-based diagnosis of CSF shunt valve obstructions. Complimentarily, we investigate CT-based methods capable of providing accurate ground truth for the training of such diagnostic tools. Using simulated test and training data, the performance of the machine-learning diagnostics in identifying and localizing obstructions within a shunt valve is evaluated regarding per-pixel sensitivity and specificity, the Dice similarity coefficient, and the false positive rate in the case of obstruction free test samples. Contrast enhanced subtraction radiography allows high-resolution, time-resolved, low-dose analysis of fluid transport in CSF shunt valves. Complementarily, photon-counting micro-CT allows to investigate valve obstruction mechanisms in detail, and to generate valid ground truth for machine learning-based diagnostics. Machine-learning-based detection of valve obstructions in simulated radiographies shows promising results, with a per-pixel sensitivity >70%, per-pixel specificity >90%, a median Dice coefficient >0.8 and <10% false positives at a detection threshold of 0.5. This ex-vivo study demonstrates obstruction detection in cerebro-spinal fluid shunt valves, combining radiological methods with machine learning under conditions compatible to future in-vivo application. Results indicate that high-resolution contrast-enhanced subtraction radiography, possibly including time-series data, combined with machine-learning image analysis, has the potential to strongly improve the diagnostics of CSF shunt valve failures. The presented method is in principle suitable for in-vivo application, considering both measurement geometry and radiological dose. Further research is needed to validate these results on real-world data and to refine the employed methods. In combination, the presented methods enable comprehensive analysis of valve failure mechanisms, paving the way for improved product development and clinical diagnostics of CSF shunt valves.