maria assunta signore

Dr. maria assunta signore


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CPChiara De Pascali
Chiara De Pascali
Luca FranciosoLuca Francioso
Luca Francioso
LGLucia Giampetruzzi
Lucia Giampetruzzi
GRGabriele Rescio
Gabriele Rescio
MSmaria assunta signore
maria assunta signore
Pietro SicilianoPietro Siciliano
Pietro Siciliano
The monitoring of some parameters, such as pressure loads, temperature, and glucose level in sweat on the plantar surface, is one of the most promising approaches for evaluating the health state of the diabetic foot and for preventing the onset of inflammatory events later degenerating in ulcerative lesions. This work presents the results of sensors microfabrication, experimental characterization and FEA-based thermal analysis of a 3D foot-insole model, aimed to advance in the development of a fully custom smart multisensory hardware–software monitoring platform for the diabetic foot. In this system, the simultaneous detection of temperature-, pressure- and sweat-based glucose level by means of full custom microfabricated sensors distributed on eight reading points of a smart insole will be possible, and the unit for data acquisition and wireless transmission will be fully integrated into the platform. Finite element analysis simulations, based on an accurate bioheat transfer model of the metabolic response of the foot tissue, demonstrated that subcutaneous inflamed lesions located up to the muscle layer, and ischemic damage located not below the reticular/fat layer, can be successfully detected. The microfabrication processes and preliminary results of functional characterization of flexible piezoelectric pressure sensors and glucose sensors are presented. Full custom pressure sensors generate an electric charge in the range 0–20 pC, proportional to the applied load in the range 0–4 N, with a figure of merit of 4.7 ± 1 GPa. The disposable glucose sensors exhibit a 0–6 mM (0–108 mg/dL) glucose concentration optimized linear response (for sweat-sensing), with a LOD of 3.27 µM (0.058 mg/dL) and a sensitivity of 21 µA/mM cm2 in the PBS solution. The technical prerequisites and experimental sensing performances were assessed, as preliminary step before future integration into a second prototype, based on a full custom smart insole with enhanced sensing functionalities.

8 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Chiara BaldacchiniChiara Baldacchini
Chiara Baldacchini
AMAntonino Francesco Montanarella
Antonino Francesco Montanarella
Luca FranciosoLuca Francioso
Luca Francioso
MSmaria assunta signore
maria assunta signore
Salvatore CannistraroSalvatore Cannistraro
Salvatore Cannistraro
Anna Rita BizzarriAnna Rita Bizzarri
Anna Rita Bizzarri
The concentration of wild-type tumour suppressor p53wt in cells and blood has a clinical significance for early diagnosis of some types of cancer. We developed a disposable, label-free, field-effect transistor-based immunosensor (BioFET), able to detect p53wt in physiological buffer solutions, over a wide concentration range. Microfabricated, high-purity gold electrodes were used as single-use extended gates (EG), which avoid direct interaction between the transistor gate and the biological solution. Debye screening, which normally hampers target charge effect on the FET gate potential and, consequently, on the registered FET drain-source current, at physiological ionic strength, was overcome by incorporating a biomolecule-permeable polymer layer on the EG electrode surface. Determination of an unknown p53wt concentration was obtained by calibrating the variation of the FET threshold voltage versus the target molecule concentration in buffer solution, with a sensitivity of 1.5 ± 0.2 mV/decade. The BioFET specificity was assessed by control experiments with proteins that may unspecifically bind at the EG surface, while 100pM p53wt concentration was established as limit of detection. This work paves the way for fast and highly sensitive tools for p53wt detection in physiological fluids, which deserve much interest in early cancer diagnosis and prognosis.

31 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
STSergei Tarasov
Sergei Tarasov
YPYulia Viktorovna Plekhanova
Yulia Viktorovna Plekhanova
VKVadim Kashin
Vadim Kashin
PGPavel Gotovtsev
Pavel Gotovtsev
MSmaria assunta signore
maria assunta signore
ARAnatoly Reshetilov
Anatoly Reshetilov
Microbial fuel cells (MFCs) are a variety of bioelectrocatalytic devices that utilize the metabolism of microorganisms to generate electric energy from organic matter. This study investigates the possibility of using a novel PEDOT:PSS/graphene/Nafion composite in combination with acetic acid bacteria Gluconobacter oxydans to create a pure culture MFC capable of effective municipal wastewater treatment. The developed MFC was shown to maintain its activity for at least three weeks. The level of COD in municipal wastewater treatment was reduced by 32%; the generated power was up to 81 mW/m2 with a Coulomb efficiency of 40%. Combining the MFC with a DC/DC boost converter increased the voltage generated by two series-connected MFCs from 0.55 mV to 3.2 V. A maximum efficiency was achieved on day 8 of MFC operation and was maintained for a week; capacitors of 6800 µF capacity were fully charged in ~7 min. Thus, G. oxydans cells can become an important part of microbial consortia in MFCs used for treatment of wastewaters with reduced pH.

14 November 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
YPYulia Viktorovna Plekhanova
Yulia Viktorovna Plekhanova
STSergei Tarasov
Sergei Tarasov
ABAleksandr Bykov
Aleksandr Bykov
NPNatalia Prisyazhnaya
Natalia Prisyazhnaya
Vladimir V KolesovVladimir V Kolesov
Vladimir V Kolesov
ARAnatoly Reshetilov
Anatoly Reshetilov
This paper considers the effect of multiwalled carbon nanotubes (MWCNTs) on the parameters of Gluconobacter oxydans microbial biosensors. MWCNTs were shown not to affect the structural integrity of microbial cells and their respiratory activity. The positive results from using MWCNTs were due to a decrease in the impedance of the electrode. The total impedance of the system decreased significantly, from 9000 kOhm (G. oxydans/chitosan composite) to 600 kOhm (G. oxydans/MWCNTs/chitosan). Modification of the amperometric biosensor with nanotubes led to an increase in the maximal signal from 65 to 869 nA for glucose and from 181 to 1048 nA for ethanol. The biosensor sensitivity also increased 4- and 5-fold, respectively, for each of the substrates. However, the addition of MWCNTs reduced the affinity of respiratory chain enzymes to their substrates (both sugars and alcohols). Moreover, the minimal detection limits were not reduced despite a sensitivity increase. The use of MWCNTs thus improved only some microbial biosensor parameters.

24 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MSmaria assunta signore
maria assunta signore
GRGabriele Rescio
Gabriele Rescio
Luca FranciosoLuca Francioso
Luca Francioso
FCFlavio Casino
Flavio Casino
Alessandro LeoneAlessandro Leone
Alessandro Leone
In this study, we propose a low-cost piezoelectric flexible pressure sensor fabricated on Kapton® (Kapton™ Dupont) substrate by using aluminum nitride (AlN) thin film, designed for the monitoring of the respiration rate for a fast detection of respiratory anomalies. The device was characterized in the range of 15–30 breaths per minute (bpm), to simulate moderate difficult breathing, borderline normal breathing, and normal spontaneous breathing. These three breathing typologies were artificially reproduced by setting the expiratory to inspiratory ratios (E:I) at 1:1, 2:1, 3:1. The prototype was able to accurately recognize the breath states with a low response time (~35 ms), excellent linearity (R2 = 0.997) and low hysteresis. The piezoelectric device was also characterized by placing it in an activated carbon filter mask to evaluate the pressure generated by exhaled air through breathing acts. The results indicate suitability also for the monitoring of very weak breath, exhibiting good linearity, accuracy, and reproducibility, in very low breath pressures, ranging from 0.09 to 0.16 kPa. These preliminary results are very promising for the future development of smart wearable devices able to monitor different patients breathing patterns, also related to breathing diseases, providing a suitable real-time diagnosis in a non-invasive and fast way.

26 March 2024 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
MSmaria assunta signore
maria assunta signore
ASA Serra
A Serra
DMDaniela Erminia MANNO
Daniela Erminia MANNO
Gianluca QuartaGianluca Quarta
Gianluca Quarta
LCLucio Calcagnile
Lucio Calcagnile
LVLuciano Velardi
Luciano Velardi
This work investigates the physical properties of Al1−xScxN thin films sputtered at low temperatures by varying the process conditions. Specifically, the films were deposited at room temperature by applying a radio frequency power equal to 150 W to an AlSc alloy (60:40) target, varying the nitrogen flux percentage in the (Ar + N2) sputtering atmosphere (30%, 40%, 50%, and 60%) and keeping constant the working pressure at 5 × 10−3 mbar. The structural and chemical properties of the Al1−xScxN films were studied by x-ray diffraction and Rutherford backscattering spectrometry techniques, respectively. The piezoelectric response was investigated by piezoresponse force microscopy. In addition, the surface potential was evaluated for the first time for Sc-doped AlN thin films by Kelvin probe force microscopy, providing piezoelectric coefficients free from the no-piezoelectric additional effect to the mechanical deformation, i.e., the electrostatic force. By alloying AlN with scandium, the piezoelectric response was strongly enhanced (up to 200% compared to undoped AlN), despite the low deposition temperature and the absence of any other additional energy source supplied to the adatoms during thin film growth, which generally promotes a better structural arrangement of polycrystalline film. This is a strategic result in the field of microelectromechanical systems completely fabricated at low temperatures.