Providing high-quality care services and fire safety for long-term care institutions is an important issue in Taiwan, which became an aging society in 2018. The fire incidents in Taiwan over the years show that nighttime fires in care institutions often cause serious casualties. It is necessary not only to understand the causes of serious nighttime fire incidents that have occurred but also to draw lessons from the fires that have been put out without causing injuries. In this study, the top two serious nighttime fire accidents in long-term care institutions in the past two decades in Taiwan were analyzed based on the publicly official and academic literature utilizing fire protection defense-in-depth strategies. For comparison, two other nighttime fire cases with similar scenarios but no casualties were also analyzed in depth about the cause of no casualties. The buildings of the four nighttime fires were equipped with fire protection equipment in their public areas. The theoretical basis of the research is the fire protection defense-in-depth strategy. In both categories of severe casualties and no severe casualties, one was caused by arson and the other one by an electrical fire, with the ignition point of a fire in the storeroom and the other in the ward. However, the end results were quite different. The analyzed results showed that the severe fires lasted for about an hour, while the fires without casualties were put out within 15 min. A well-constructed second layer of defense measures could effectively contain a fire, and an effective third layer of measures could avoid casualties. The death rate of personnel can be reduced from a dozen to zero, and the burning time is also greatly reduced. The results could be used as a reference for emergency measures in long-term care institutions.
Air curtain systems have been proposed as a supplementary smoke control strategy for vehicle tunnels, particularly where structural constraints limit the installation or upgrading of conventional ventilation systems. However, most previous studies rely on numerical simulations or fixed experimental facilities, while flexible experimental platforms and the influence of vehicle obstruction on smoke behavior remain less explored. This study experimentally investigates the smoke confinement performance of an air curtain using a 1:18 modular detachable scaled vehicle tunnel model. The modular configuration enables flexible assembly and adjustment of the experimental setup for different test conditions. A series of laboratory experiments was conducted using a liquefied petroleum gas (LPG) burner to simulate a vehicle fire. Temperature measurements and smoke visualization were performed under different air curtain jet velocities and vehicle obstruction conditions to analyze the interaction between the air curtain jet and buoyancy-driven smoke flow. The results show that the air curtain significantly restricts the upstream propagation of hot smoke and modifies the thermal field inside the tunnel. When the jet velocity reached approximately 5 m/s, the temperature in the protected region decreased by about 25–35% compared with the case without an air curtain. In addition, the presence of vehicle models altered the airflow structure and increased heat accumulation in the middle region of the tunnel cross-section. These results demonstrate that the proposed modular tunnel model provides a reliable experimental platform for tunnel fire research and highlights the importance of considering vehicle obstruction effects in tunnel smoke control studies.