An ultra-wide detection range refractive-index sensor based on surface plasmon resonance (SPR) with photonic crystal fiber (PCF) is designed and discussed. The central air hole of the fiber is injected with the analyte. The properties of refractive-index sensor are investigated with different structure parameters. Simulation results show that the proposed sensor has an ultra-wide detection range from 1.29 to 1.49. The refractive index sensitivities of x-polarized and y-polarized core mode are -4156.82 nm/RIU and -3703.64 nm/RIU respectively, and the corresponding linear fitting degrees are 0.99598 and 0.99236. The designed refractive-index sensor with ultra-wide detection range has a great potential in the fields of biology, chemistry, environment and medicine.
12 September 2016 in Optical and Quantum Electronics
Marine monitoring often requires the temperature measurement accuracy to be less than 1 mK. A series of regularly arranged temperature points is taken to calibrate the equation expressing resistance-temperature characteristics under ocean conditions. Seventy-two negative temperature coefficient thermistors underwent coincident measurement procedures with nine equally spaced points from -5 to 35 °C in a high-precision thermostatic water bath, followed by calibration using Lagrange interpolation and least-squares fitting methods. Ten of these thermistors, with average interpolation errors below 0.1 mK and calibration uncertainty estimated at 0.6 mK ( k = 2), were used to study the impact of the number and placement of calibration points on interpolation error, aiming to enhance measurement precision across the ocean temperature range. The results reveal that the standard deviation for the 10 thermistors using six unequally spaced points was only 20% higher than when using nine equally spaced points. However, the standard deviation for five equally spaced points nearly doubled, with a maximum difference of 0.1 mK, still achieving sub-millikelvin accuracy. By adjusting the calibration points near both ends of the range, the optimal placement for five calibration points was found to minimize temperature deviation and adhere to the Chebyshev criterion. This ideal distribution, determined through sequential calculations, contributes to improved calibration precision.
A highly sensitive hollow-core photonic crystal fiber (HC-PCF) gas-sensing network based on intracavity absorption is designed and experimentally verified. The capacity of the multichannel sensing network is expanded by time division multiplexing and wavelength division multiplexing technology. The voltage gradient method is employed in the wavelength scanning process of Fabry–Perot (F-P) filter to enhance the detection efficiency up to six times. The proposed sensing network has 16 sensing points. Experimental results show that the minimum detection limit (MDL) of this sensing system is 25.91 ppm and 26.85 ppm at the acetylene gas absorption peaks of 1530.371 nm and 1531.588 nm, respectively. As far as we know, it is the first time to obtain an intracavity sensing network via the application of an optical switch and DWDM at the same time. The sensing network can be used for high-capacity, low-concentration dangerous gas detection. It has great potential in environmental monitoring, industrial manufacturing, safety inspection and similar occasions.