Ester Hamatwi

Ms. Ester Hamatwi

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2023 in IEEE Access
Verified
Journal Article
Open access
EHEster Hamatwi
Ester Hamatwi
OIOdunAyo IMORU
OdunAyo IMORU
MKMatheus M. Kanime
Matheus M. Kanime
HKHitila S. A. Kanelombe
Hitila S. A. Kanelombe
This study focused on comparing the performance of three high impedance fault detection techniques for the case of a distribution network to select the technique that is best suited for detecting faults in this network. The three most common techniques; discrete Fourier transform, discrete wavelet transform, and the power spectrum among other techniques were selected for the research work based on literature. The distribution network was modelled in MATLAB/Simulink, along with the High Impedance Fault condition. These fault detection techniques were modelled and applied separately to the distribution network under different operating conditions: high impedance fault, load switching, and normal operation. The suitability of these techniques for the distribution network is evaluated by comparing them in terms of accuracy, processing time, and fault detection margin. The power spectrum technique was found to be the most suitable technique for detecting high impedance faults on a distribution network, with a 100% accuracy, a shorter processing time, and a larger fault detection margin.

26 December 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
EHEster Hamatwi
Ester Hamatwi
PBPaul Barendse
Paul Barendse
AKAzeem Khan
Azeem Khan
For laboratory-based systems, the selection of components is critical to ensure proper representation of the actual system. In past investigations, researchers made use of small-scale off-the-shelf wound rotor induction machines (WRIMs) to perform laboratory-based studies. However, there are no reports validating their applicability in comparison to using the actual machines. In this regard, this paper investigates the correlation between the dimensional parameters and the electrical asymmetry indicators for a large-scale wind generator and laboratory-based generators. For the latter, a comparison is made between using a standard small-scale off-the-shelf WRIM and a micromachine. It is shown that the harmonic frequencies in a healthy machine and those due to inherent asymmetries appear at the same positions on the stator current spectrum for the three machines. However, there is a difference in the amplitudes of these components, given their dependence on the winding factors for a specific machine. The dimensional analysis techniques used to scale down the large-scale generator into a micromachine ensure that these parameters are related. However, this is not the case for the standard small-scale WRIM. Further work demonstrates the correlation of the fault-related harmonics between the micromachine and the large-scale machine for a rotor inter-turn fault condition. Micromachines are designed to ensure that the time constants are proportional representations of the larger machine, thus providing an accurate reflection of what is expected under transient operating conditions of wind turbines. This would assist in the development of condition monitoring strategies that are suited for the actual systems in the industry.

1 January 2017 in Journal of Control Science and Engineering
Verified
Journal Article
Open access
PDF file
EHEster Hamatwi
Ester Hamatwi
Innocent Ewean DavidsonInnocent Ewean Davidson
Innocent Ewean Davidson
MGMichael N. Gitau
Michael N. Gitau
Due to the intermittent nature of wind, the wind power output tends to be inconsistent, and hence maximum power point tracking (MPPT) is usually employed to optimize the power extracted from the wind resource at a wide range of wind speeds. This paper deals with the rotor speed control of a 2 MW direct-driven permanent magnet synchronous generator (PMSG) to achieve MPPT. The proportional-integral (PI), proportional-derivative (PD), and proportional-integral-derivative (PID) controllers have widely been employed in MPPT studies owing to their simple structure and simple design procedure. However, there are a number of shortcomings associated with these controllers; the trial-and-error design procedure used to determine the P, I, and D gains presents a possibility for poorly tuned controller gains, which reduces the accuracy and the dynamic performance of the entire control system. Moreover, these controllers’ linear nature, constricted operating range, and their sensitivity to changes in machine parameters make them ineffective when applied to nonlinear and uncertain systems. On the other hand, phase-lag compensators are associated with a design procedure that is well defined from fundamental principles as opposed to the aforementioned trial-and-error design procedure. This makes the latter controller type more accurate, although it is not well developed yet, and hence it is the focus of this paper. The simulation results demonstrated the effectiveness of the proposed MPPT controller.

17 September 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
EHEster Hamatwi
Ester Hamatwi
PBPaul Barendse
Paul Barendse
AKAzeem Khan
Azeem Khan
This work presents a micro-based doubly fed induction generator (DFIG) test rig developed for fault diagnostic purposes. Experiments have been conducted by emulating the stator interturn short circuit (ITSC), rotor ITSC, and static eccentricity (SE) fault conditions on the micro-DFIG. The novelty of this work lies in the use of the various DFIG controller signals, in addition to the stator current signal which has extensively been used in previous investigations for fault detection. Another contribution is in identifying which signal is best suited for diagnosing different electromechanical faults in the micro-DFIG operating at sub-synchronous and super-synchronous speeds, while also injecting different amounts of active power into the grid. The comparative studies conducted in this work have illustrated that the stator current and the $q$ -axis component of the rotor current error ( $error_{Irq}$ ) signals were best suited for diagnosing the ITSC and SE faults, whereby the sensitivity of the fault indices in these signals was more significant at lower speeds. Overall, the $(1-2s)f_{s}$ index in the stator current signal was identified to adequately detect stator ITSC faults at different power levels, whereas for the rotor ITSC fault, it is the $2sf_{s}$ index in the $error_{Irq}$ that is recommended for fault diagnosis. For the SE fault condition, it is the $f_{s}\pm f_{r}$ index in the stator current signal that is recommended for use at different power levels. The use of multiple fault diagnosis signals and their extended sensitivity analysis under different DFIG operating conditions significantly improves upon existing diagnosis techniques, offering more robust and reliable fault detection in DFIGs.

13 March 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
VNVilho Ndemuhanga Nghuumbwa
Vilho Ndemuhanga Nghuumbwa
TWTOM WANJEKECHE
TOM WANJEKECHE
EHEster Hamatwi
Ester Hamatwi
MKMatheus Mwatile Kanime
Matheus Mwatile Kanime
Namibia’s rural communities continue to experience limited and unreliable electricity access despite the country’s exceptional solar, wind, and biomass renewable energy re-sources potential. Conventional grid extension remains financially and technically impractical for dispersed off-grid settlements, underscoring the need for cost-effective, re-renewable based alternatives. This paper presents a resource-driven design and multi objective optimization framework for Hybrid Renewable Energy Systems (HRESs) tailored to Namibia’s off-grid communities. The proposed model integrates solar PV, wind turbines, biomass generators, and hydrogen-based fuel cells with hybridized energy storage consisting of batteries, supercapacitors, and hydrogen tanks. Using the Non-dominated sorting Genetic Algorithm-II (NSGA-II), the system simultaneously minimizes Total Life Cycle Cost (TLCC), Levelized Cost of Electricity (LCOE), Loss of Power Supply Probability (LPSP), Carbon dioxide (CO₂) emissions, and Wasted Renewable Energy (WRE). The framework is applied to three rural villages, Oluundje, Ombudiya, and Onguati using high-resolution, site-specific renewable resource datasets and community-level load forecasts. Results demonstrate that resource-aligned configurations substantially improve system reliability (up to 99.28%), reduce LCOE (0.0023–0.0811 USD/kWh), and optimize dispatch behavior across seasonal variations. Storage hybridization further enhances stability by balancing transient and long-duration deficits. Com-pared to existing diesel mini-grids, the optimized HRESs achieve markedly superior techno-economic and environmental performance. The proposed framework offers a scalable, adaptable, and policy-ready tool for accelerating sustainable rural electrification in Namibia.

25 June 2026 in Energies
Verified
Journal Article
Open access
PDF file
VNVilho Ndemuhanga Nghuumbwa
Vilho Ndemuhanga Nghuumbwa
TWTOM WANJEKECHE
TOM WANJEKECHE
EHEster Hamatwi
Ester Hamatwi
MKMatheus Mwatile Kanime
Matheus Mwatile Kanime
Namibia’s rural communities continue to experience limited and unreliable electricity access despite the potential of the country’s exceptional solar, wind, and biomass renewable energy resources. Conventional grid extension remains financially and technically impractical for dispersed off-grid settlements, underscoring the need for cost-effective, renewable-based alternatives. This paper presents a resource-driven design and multi-objective optimization framework for Hybrid Renewable Energy Systems (HRESs) tailored to Namibia’s off-grid communities. The proposed model integrates solar PV, wind turbines, biomass generators, and hydrogen-based fuel cells with a hybridized energy storage consisting of batteries, supercapacitors, and hydrogen tanks. Using the Non-dominated sorting Genetic Algorithm-II (NSGA-II), the system simultaneously minimizes Total Life Cycle Cost (TLCC), Levelized Cost of Electricity (LCOE), Loss of Power Supply Probability (LPSP), carbon dioxide (CO2) emissions, and Wasted Renewable Energy (WRE). The framework is applied to three rural villages, Oluundje, Ombudiya, and Onguati, using high-resolution, site-specific renewable resource datasets and community-level load forecasts. The results demonstrate that resource-aligned configurations substantially improve system reliability (up to 99.28%), reduce LCOE (0.0023–0.0811 USD/kWh), and optimize dispatch behaviour across seasonal variations. Storage hybridization further enhances stability by balancing transient and long-duration deficits. Compared to existing diesel mini-grids, the optimized HRESs achieve markedly superior techno-economic and environmental performance. The proposed framework offers a scalable, adaptable, and policy-ready tool for accelerating sustainable rural electrification in Namibia.