Carlijn Tenbergen

Ms. Carlijn Tenbergen

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2022 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
CTCarlijn Tenbergen
Carlijn Tenbergen
GMGregory J. Metzger
Gregory J. Metzger
TSTom W. J. Scheenen
Tom W. J. Scheenen
Multiparametric MRI of the prostate at clinical magnetic field strengths (1.5/3 Tesla) has emerged as a reliable noninvasive imaging modality for identifying clinically significant cancer, enabling selective sampling of high-risk regions with MRI-targeted biopsies, and enabling minimally invasive focal treatment options. With increased sensitivity and spectral resolution, ultra-high-field (UHF) MRI (≥ 7 Tesla) holds the promise of imaging and spectroscopy of the prostate with unprecedented detail. However, exploiting the advantages of ultra-high magnetic field is challenging due to inhomogeneity of the radiofrequency field and high local specific absorption rates, raising local heating in the body as a safety concern. In this work, we review various coil designs and acquisition strategies to overcome these challenges and demonstrate the potential of UHF MRI in anatomical, functional and metabolic imaging of the prostate and pelvic lymph nodes. When difficulties with power deposition of many refocusing pulses are overcome and the full potential of metabolic spectroscopic imaging is used, UHF MR(S)I may aid in a better understanding of the development and progression of local prostate cancer. Together with large field-of-view and low-flip-angle anatomical 3D imaging, 7 T MRI can be used in its full strength to characterize different tumor stages and help explain the onset and spatial distribution of metastatic spread.

29 December 2023 in Investigative Radiology
Verified
Journal Article
Open access
CTCarlijn Tenbergen
Carlijn Tenbergen
AFAnsje S. Fortuin
Ansje S. Fortuin
JAJack J.A. Ma van Asten
Jack J.A. Ma van Asten
AVAndor Bsc Veltien
Andor Bsc Veltien
BPBart W.J. Philips
Bart W.J. Philips
TSTom W.J. Scheenen
Tom W.J. Scheenen
Background: Accurate detection of lymph node (LN) metastases in prostate cancer (PCa) is a challenging but crucial step for disease staging. Ultrasmall superparamagnetic iron oxide (USPIO)–enhanced magnetic resonance imaging (MRI) enables distinction between healthy LNs and nodes suspicious for harboring metastases. When combined with MRI at an ultra-high magnetic field, an unprecedented spatial resolution can be exploited to visualize these LNs. Purpose: The aim of this study was to explore USPIO-enhanced MRI at 7 T in comparison to 3 T for the detection of small suspicious LNs in the same cohort of patients with PCa. Materials and Methods: Twenty PCa patients with high-risk primary or recurrent disease were referred to our hospital for an investigational USPIO-enhanced 3 T MRI examination with ferumoxtran-10. With consent, they underwent a 7 T MRI on the same day. Three-dimensional anatomical and T2*-weighted images of both examinations were evaluated blinded, with an interval, by 2 readers who annotated LNs suspicious for metastases. Number, size, and level of suspicion (LoS) of LNs were paired within patients and compared between field strengths. Results: At 7 T, both readers annotated significantly more LNs compared with 3 T (474 and 284 vs 344 and 162), with 116 suspicious LNs on 7 T (range, 1–34 per patient) and 79 suspicious LNs on 3 T (range, 1–14 per patient) in 17 patients. For suspicious LNs, the median short axis diameter was 2.6 mm on 7 T (1.3–9.5 mm) and 2.8 mm for 3 T (1.7–10.4 mm, P = 0.05), with large overlap in short axis of annotated LNs between LoS groups. At 7 T, significantly more suspicious LNs had a short axis <2.5 mm compared with 3 T (44% vs 27%). Magnetic resonance imaging at 7 T provided better image quality and structure delineation and a higher LoS score for suspicious nodes. Conclusions: In the same cohort of patients with PCa, more and more small LNs were detected on 7 T USPIO-enhanced MRI compared with 3 T MRI. Suspicious LNs are generally very small, and increased nodal size was not a good indication of suspicion for the presence of metastases. The high spatial resolution of USPIO-enhanced MRI at 7 T improves structure delineation and the visibility of very small suspicious LNs, potentially expanding the in vivo detection limits of pelvic LN metastases in PCa patients.

19 January 2023 in Life
Verified
Journal Article
Open access
PDF file
CTCarlijn Tenbergen
Carlijn Tenbergen
LRLoreen Ruhm
Loreen Ruhm
SYSjoerd Ypma
Sjoerd Ypma
AHArend Heerschap
Arend Heerschap
AHAnke Henning
Anke Henning
TSTom W. J. Scheenen
Tom W. J. Scheenen
In in vivo 1H-MRSI of the prostate, small matrix sizes can cause voxel bleeding extending to regions far from a voxel, dispersing a signal of interest outside that voxel and mixing extra-prostatic residual lipid signals into the prostate. To resolve this problem, we developed a three-dimensional overdiscretized reconstruction method. Without increasing the acquisition time from current 3D MRSI acquisition methods, this method is aimed to improve the localization of metabolite signals in the prostate without compromising on SNR. The proposed method consists of a 3D spatial overdiscretization of the MRSI grid, followed by noise decorrelation with small random spectral shifts and weighted spatial averaging to reach a final target spatial resolution. We successfully applied the three-dimensional overdiscretized reconstruction method to 3D prostate 1H-MRSI data at 3T. Both in phantom and in vivo, the method proved to be superior to conventional weighted sampling with Hamming filtering of k-space. Compared with the latter, the overdiscretized reconstructed data with smaller voxel size showed up to 10% less voxel bleed while maintaining higher SNR by a factor of 1.87 and 1.45 in phantom measurements. For in vivo measurements, within the same acquisition time and without loss of SNR compared with weighted k-space sampling and Hamming filtering, we achieved increased spatial resolution and improved localization in metabolite maps.

11 September 2025 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
ASAngeliki Stamatelatou
Angeliki Stamatelatou
CTCarlijn Tenbergen
Carlijn Tenbergen
SNSahar Nassirpour
Sahar Nassirpour
PCPaul Chang
Paul Chang
JAJack van Asten
Jack van Asten
TSTom Scheenen
Tom Scheenen
Objective: To improve B 0 field homogeneity in prostate MR imaging and spectroscopy using a custom-designed 16-channel external local shim coil array . Methods: In vivo prostate imaging was performed in seven healthy volunteers (mean age: 40.7 years) without bowel preparation. A simulation study determined the most robust configuration of the add-on shim coil together with shim coils from the MR system. The combination of the add-on shim coil array with 1st-order shims of the MR scanner was used and compared to the MR system’s reference standard of conventional 1st and 2nd-order shimming. Performance was evaluated using the standard deviation (SD) of off-resonance frequencies (ΔB 0 ) from B 0 -maps, the distortion of diffusion-weighted images (DWI) by the Dice similarity coefficient (DSC) with reference to T 2 W images, and the citrate linewidths of 1 H-MR spectroscopic imaging ( 1 H-MRSI) of the prostate. Results: Overall, improvements were made with the combination of coils, with DSC rising from 0.90 ± 0.02 to 0.92 ± 0.02 ( p = 0.01), a reduction in the SD of ΔB 0 from 18.5 ± 4.7 Hz to 16.5 ± 3.6 Hz, and a decrease in citrate linewidths from 8.3 ± 5.7 Hz to 7.9 ± 3.6 Hz ( p = 0.018), all compared to the reference standard of conventional 1st and 2nd-order shimming. Conclusion: A dedicated external shim coil array can improve B0 homogeneity in the prostate, enhancing image quality and precision in multi-parametric MRI.