Idiopathic toe walking (ITW) is a gait deviation characterized by forefoot contact with the ground and excessive ankle plantarflexion over the entire gait cycle observed in otherwise-typical developing children. The clinical evaluation of ITW is usually performed using optoelectronic systems analyzing the sagittal component of ankle kinematics and kinetics. However, in standardized laboratory contexts, these children can adopt a typical walking pattern instead of a toe walk, thus hindering the laboratory-based clinical evaluation. With these premises, measuring gait in a more ecological environment may be crucial in this population. As a first step towards adopting wearable clinical protocols embedding magneto-inertial sensors and pressure insoles, this study analyzed the performance of three algorithms for gait events identification based on shank and/or foot sensors. Foot strike and foot off were estimated from gait measurements taken from children with ITW walking barefoot and while wearing a foot orthosis. Although no single algorithm stands out as best from all perspectives, preferable algorithms were devised for event identification, temporal parameters estimate and heel and forefoot rocker identification, depending on the barefoot/shoed condition. Errors more often led to an erroneous characterization of the heel rocker, especially in shoed condition. The ITW gait specificity may cause errors in the identification of the foot strike which, in turn, influences the characterization of the heel rocker and, therefore, of the pathologic ITW behavior.
Introduction: Gait impairments are common in People with Multiple Sclerosis (PwMS). Several studies have examined the clinometric properties of Inertial Measurement Units (IMUs), with LDLJa identified as a robust metric for gait smoothness. However, its responsiveness and interpretability have not been explored. Methods: This cross-sectional study at IRCCS Santa Lucia Hospital enrolled 44 PwMS (age: 28-71; EDSS: 0-6) and 43 age- and gait-speed-matched healthy participants (HP). Two physiotherapists conducted assessments with five synchronized IMUs during a 10-meter walk at participants’ preferred speed. Data were collected at baseline (T0) and after 4 weeks of training (T1). Results: Significant differences in log dimensionless jerk (LDLJa) were found between PwMS and HP in the AP (p < 0.001, d = 0.63), ML (p < 0.001, d = 1.08), and CC (p = 0.03, d = 0.68) directions. PwMS had lower LDLJaAP values (< -4.88) and LDLJaML values (< -5.40) with probabilities of 63% and 76%, respectively. ΔLDLJaML demonstrated good responsiveness to rehabilitation (AUC ~0.80), with improvements >4.02% representing the optimal MCID for clinical improvement in MiniBesTest. Conclusion: Lower LDLJa values in the AP and ML directions characterize gait smoothness impairment in PwMS. LDLJa in the ML direction is responsive to balance-focused rehabilitation, highlighting its potential for tracking gait disorders and rehabilitation progress.
Movement smoothness is a critical metric for evaluating motor control and sensorimotor impairments, with increasing relevance in neurorehabilitation and everyday functional assessments. This study investigates the correlation between two smoothness metrics (Log Dimensionless Jerk): LDLJV, derived from body center of mass (BCoM) trajectories using a gold-standard stereophotogrammetric system, and LDLJA, calculated from acceleration data recorded via an inertial measurement unit (IMU) placed at the L1–L2 level. Ten healthy adults (six men and four women; height: 1.71 ± 0.08 m; body mass: 68.2 ± 10.2 kg; age: 34.5 ± 8.5 years) walked on a treadmill at seven different speeds, with stride-specific data analyzed to compute smoothness indices for three anatomical components (antero-posterior, medio-lateral, cranio-caudal). Concordance between the metrics was evaluated using Bland–Altman analysis, Spearman’s correlation, and the mean absolute percentage error. The results revealed weak correlations and substantial biases across all components and speeds, reflecting inherent differences between IMU- and BCoM-derived data. Correcting biases improved alignment but did not eliminate discrepancies. The findings highlight that LDLJA captures only localized trunk accelerations, whereas BCoM-derived LDLJV approximates whole-body dynamics, making direct substitution infeasible. This study emphasizes the need for careful interpretation of IMU-based metrics and contributes to refining their application in real-world gait analyses.
Severe traumatic brain injury (sTBI) often results in significant impairments in gait stability, symmetry, and smoothness. Inertial measurement units (IMUs) have emerged as powerful tools to quantify these aspects of gait, but their clinometric properties in sTBI populations remain underexplored. This study aimed to assess the test-retest reliability and minimal detectable change (MDC) of three IMU-derived indices—normalized Root Mean Square (nRMS), improved Harmonic Ratio (iHR), and Log Dimensionless Jerk (LDLJ)—during a 10 m walking test for sTBI survivors. Forty-nine participants with sTBI completed the walking test, with IMUs placed on key body segments to capture accelerations and angular velocities. Test-retest analyses revealed moderate to excellent reliability for nRMS and iHR in anteroposterior (ICC: 0.78–0.95 and 0.94, respectively) and craniocaudal directions (ICC: 0.95), with small MDC values, supporting their clinical applicability (MDC: 0.04–0.3). However, iHR in the mediolateral direction exhibited greater variability (ICC: 0.80; MDC: 9.74), highlighting potential sensitivity challenges. LDLJ metrics showed moderate reliability (ICC: 0.57–0.77) and higher MDC values (0.55–0.75), suggesting the need for further validation. These findings underscore the reliability and sensitivity of specific IMU-derived indices in detecting meaningful gait changes in sTBI survivors, paving the way for refined assessments and monitoring the rehabilitation process of sTBI survivors. Future research should explore these indices’ responsiveness to interventions and their correlation with functional outcomes.
Idiopathic toe walking (ITW) is a gait deviation characterized by forefoot contact with the ground, possibly enhancing the risk of falling and causing Achilles’ tendon shortening and psychological discomfort. Between possible treatments, foot orthosis may limit ITW when worn. With these premises, the effects of a novel foot orthosis (A.Dyn.O.®) on ankle function were analyzed in children with ITW during gait. Twenty-one children were recruited in the study after ITW diagnosis. At follow-up assessment after a habituation period of at least two weeks, participants walked in barefoot condition and while wearing A.Dyn.O.®. Kinetics and kinematics were derived from a multi-segment foot model using an optoelectronic system. Gait spatiotemporal parameters, ankle kinetic and kinematic and rockers timing were analyzed. Lastly, ITW severity was classified according to Alvarez classification. Differences between conditions were verified with paired t-test. Statistical parametric mapping was used to evaluate differences in the entire kinematic and kinetic waveforms. Wearing A.Dyn.O.®, step cadence was reduced, step length, stance phase and stride duration increased; physiological heel rocker was present, thus postponing the timing of ankle and forefoot rockers; ankle dorsiflexion angular excursion, range of motion, maximal dorsiflexor and plantarflexor moments together with maximal power absorption and production were all amplified. While wearing it, A.Dyn.O.® limited gait deviations typical of ITW and improved ITW severity classification for most of the participants. These findings suggest that the use of A.Dyn.O.® may assist ITW treatment, preventing children from toe walking and thus limiting its side effects.
People with multiple sclerosis (PwMS) experience loss of gait stability, smoothness, and symmetry, which affects quality of life and requires accurate evaluation for effective rehabilitation. Inertial measurement units (IMUs) offer a promising approach to monitor gait quality by quantifying indices reflecting stability, symmetry, and smoothness whose minimal detectable changes (MDCs) are not defined in people with MS (PwMS). to assess the within-day test-retest reliability and MDCs of IMUs - derived gait stability, symmetry, and smoothness metrics in PwMS during the 10 m walking test (10MWT). 58 PwMS wore five IMUs and performed the10MWT twice with a 10 min rest between each trial. Log dimensionless jerk (LDLJ) and improved Harmonic Ratio (iHR) were calculated for each gait trial based on the signals from the pelvis - mounted IMU, normalized Root Mean Square (nRMS) were calculated also from the head and sternum-mounted IMUs. Intraclass correlation coefficient (ICC) were calculated between the results of the two 10MWT to assess test -retest reliability, and minimal detectable change scores were calculated. Reliability of the investigated parameters ranged from moderate to excellent values, with ICC ranging from 0.64 to 0.98. MDC values ranged from 0.09 to 0.53 for the nRMS, from 7.54 to 11.36 for the iHR and from 0.15 to 0.20 for the LDLJ. This study showed moderate to excellent reliability for the investigated indexes when calculated based on 10MWT, with the LDLJ showing the highest reliability, thus providing a reliable smoothness metric in pwMS. Also, nRMS showed good reliability, but caution is warranted with iHR due to its lower reliability and higher MDCs.