Rooftop gardens ona building have proved to be a good way to improve its storm water management, but many other benefits can be obtained from the installation of these systems, such as reduction of energy consumption, decrease of the heat stress, abatement on CO2 emissions, etc. In this paper, the effect from the presence of these rooftop gardens on abuilding’s energy consumption has been investigated by experimental campaigns using a green roof ona public building in a Mediterranean location in Spain. The obtained results demonstrate a substantial improvement by the installation of the green roof onthe building’s cooling energy demand for a standard summer day, in the order of 30%, and a reduction, about 15%, in the heating energy demand for a winter day. Thus, given the longer duration of the summer conditions along the year, a noticeable reduction on energy demand could be obtained. Simulation analysis, using commercial software TRNSYS code, previously calibrated using experimental data for typical summer and winter days, allows for the extrapolation to the entire year of these results deducing noticeable improvement in energy efficiency, in the order of 19%, but with an increase of 6% in the peak power during the winter period.
Similarly to how Steinmetz developed his theory of alternating current in single-phase sinusoidal systems, a few formal relationships between expressions of the instantaneous and Buchholz’s apparent power in three-phase systems were identified in this paper. Based on these relationships, a methodology to express Buchholz’s apparent power and its components in any three-phase, wye-configured system—sinusoidal or non-sinusoidal, balanced or unbalanced—through instantaneous power expressions was established. The application of the proposed method to the entire system allowed the determination of a novel quantity referred to as neutral-displacement power, which measured the impacts of the phenomena caused by the neutral path operation on the values of the source and load apparent power. These impacts were analyzed using a real-world urban installation with a neutral conductor deterioration simulation via an Excel platform as an application example.
8 August 2024 in e-Prime - Advances in Electrical Engineering, Electronics and Energy
Building decarbonization strategy with Distributed renewable energy sources (DRES) is applied and extended worldwide for its climate change mitigation benefits, however, it generates debate regarding equity in sharing electric system operation costs. To analyze DRES effects on equity, it is conducted a case study, in which same residential consumer is evaluated in three different markets (Spain, Mexico, Colombia). We analyze not only electrical system technical variables, but we also include society’s economic, social, technological, and environmental characteristics. Next, energy, economic, and environmental benefits are obtained in each the three case studies, analyzing the impact of using DERS on equity to recover electric system operating costs. We also evaluate whether tariff mechanisms are equitable to motivate all consumers participation, as well as whether all consumers have equal opportunity for using DERS. We conclude that tariff mechanisms in Mexico and Colombia lead to inequity to recover market operating costs, favoring large consumers with high incomes. Furthermore, tariff mechanisms discourage the use of DERS by small and medium consumers due to economic, social, and technological aspects. In Spain, inequity arises due to increased difficulty for some consumers to use DERS, i.e., consumers in apartment buildings.
Biophotolysis has emerged as a promising biotechnological alternative for the sustainable production of hydrogen, owing to the photosynthetic capacity of microalgae to convert solar energy into reducing equivalents under controlled conditions. This systematic review analyzed literature published between 2019 and 2024 in Science Direct, Scopus, and ResearchGate, with the objective of identifying the operational parameters, microorganisms, reactor configurations, and technological advances that determine process performance. Specific keywords and Boolean operators were applied to ensure a rigorous selection of recent studies. The findings indicate that Chlamydomonas reinhardtii is the most widely studied species, achieving hydrogen yields of up to 14.5 mL/L·h under optimized conditions such as sulfur deprivation, pH values between 7.0 and 7.5, moderate light intensities (100–200 μmol·m⁻²·s⁻¹), and enriched media such as TAP. Batch-type reactors demonstrated the highest efficiencies due to improved control of oxygen accumulation and light distribution, whereas tubular systems showed comparatively lower performance. This also reinforces the potential of biophotolysis for integrated bioremediation applications. Overall, biophotolysis represents a promising pathway for green hydrogen generation; however, its scalability requires further innovation in photobioreactor design, enzyme stability, and strategies to mitigate oxygen inhibition.