Huiling Jiang

Huiling Jiang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2022 in Fire
Verified
Journal Article
Open access
PDF file
QDQing Deng
Qing Deng
BZBo Zhang
Bo Zhang
ZZZheng Zhou
Zheng Zhou
HDHongyu Deng
Hongyu Deng
LZLiang Zhou
Liang Zhou
HJHuiling Jiang
Huiling Jiang
Fire is one of the most common and harmful disasters in real life. In 2021, firefighting teams in China reported 748,000 fires, resulting in 1987 deaths, 2225 injuries and CNY 6.75 billion of direct property losses, which account for 0.05‰ of GDP. Scientific and accurate estimation of evacuation time can provide decision support for intelligent fire evacuation. This paper aims to effectively improve the evacuation efficiency of people in large buildings, especially for a scenario with intricate evacuation passages. There are many factors that make a difference in evacuation time, such as individual behavior, occupant density, exit width, and so on. The people distribution density is introduced to effectively assess the impact of unstable pedestrian flow and unbalanced distribution in the process of evacuation. The verification results show that there is a strong positive correlation between people distribution density and evacuation time. Combining the people distribution density with many other factors, the training dataset is built by Pathfinder to learn the relationship between evacuation time and influencing factors. Finally, an evacuation time prediction model is established to estimate the consumption time that occupants spend on moving in the evacuation process based on stacking integration. The model can assist occupants in choosing different channels for evacuation in advance. After testing, the average error between the predicted evacuation consumption time and the reference time is 3.63 s. The result illustrates that the model can accurately predict the time consumed in the process of evacuation.

10 December 2024 in International Journal of Disaster Risk Science
Verified
Journal Article
Open access
PDF file
QDQing Deng
Qing Deng
ZZZheng Zhou
Zheng Zhou
SZShirong Zhang
Shirong Zhang
LDLi Deng
Li Deng
YXYe Xu
Ye Xu
Feng YuFeng Yu
Feng Yu
Subway fires often cause significant casualties and property losses. There are some special bidirectional coupling scenarios during subway fires, such as firefighters moving against the evacuation flow to extinguish fires, emergency managers going to the fire scene to respond to emergencies, or other similar scenarios. How to evacuate passengers quickly and enable responders to enter the fire scene has become a big challenge for subway fire evacuation and response. The core goal is to reduce the degree of mutual interaction between these people moving in opposite directions. In this study, the impact of counterflow individuals and proactive avoidance behavior on evacuation processes was investigated through experiments and simulations. The Fire Dynamic Simulator was used to simulate the development of a fire scenario to determine the available safe egress time. Micro-evacuation experiments were conducted to obtain actual evacuation parameters, such as the speeds of different objects. With these parameters as input, a macro subway fire scenario was built to simulate the bidirectional evacuation process. Consistent conclusions were obtained from the experiments and evacuation simulations. The results indicate that the overall evacuation time increases with the number of retrograders. Proactive avoidance behavior can effectively reduce the travel time of counterflow individuals, but it causes slight delays for forward-moving evacuees. An optimization strategy was implemented through conductor guidance. All passengers can successfully evacuate under the optimization strategy, with a 25.3% improvement in overall evacuation time. This research provides some insights into the coordinated evacuation and emergency response during subway fires or similar scenarios.

28 February 2024 in Toxics
Verified
Journal Article
Open access
PDF file
ZZZhengqing Zhou
Zhengqing Zhou
YLYuzhe Liu
Yuzhe Liu
HJHuiling Jiang
Huiling Jiang
ZBZhi-ming Bai
Zhi-ming Bai
LSLingxia Sun
Lingxia Sun
WZWenwen Zhao
Wenwen Zhao
In order to investigate the impact of environmental temperature and atmospheric humidity on the leakage and diffusion of hydrogen fluoride (HF) gas, this study focused on the real scenario of an HF chemical industrial park. Based on the actual dispersion scenario of HF gas, a proportionally scaled-down experimental platform for HF gas leakage was established to validate the accuracy and feasibility of numerical simulations under complex conditions. Using the validated model, the study calculated the complex scenarios of HF leakage and diffusion within the temperature range of 293 K to 313 K and the humidity range of 0% to 100%. The simulation results indicated that different environmental temperatures had a relatively small impact on the hazardous areas (the lethal area, severe injury area, light injury area, and maximum allowable concentration (MAC) area) formed by HF gas leakage. At 600 s of dispersion, the fluctuation range of hazardous area sizes under different temperature conditions was between 3.11% and 13.07%. In contrast to environmental temperature, atmospheric relative humidity had a more significant impact on the dispersion trend of HF leakage. Different relative humidity levels mainly affected the areas of the lethal zone, light injury zone, and MAC zone. When HF continued to leak and disperse for 600 s, compared to 0% relative humidity, 100% relative humidity reduced the lethal area by 35.7%, while increasing the light injury area and MAC area by 27.26% and 111.6%, respectively. The impact on the severe injury area was relatively small, decreasing by 1.68%. The results of this study are crucial for understanding the dispersion patterns of HF gas under different temperature and humidity conditions.

26 January 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ZZZhengqing Zhou
Zhengqing Zhou
LCLujia Chai
Lujia Chai
TWTian-yi Wang
Tian-yi Wang
HJHuiling Jiang
Huiling Jiang
ZBZhi-ming Bai
Zhi-ming Bai
JSJinguo Sang
Jinguo Sang
The reactivity of Al nanoparticles is significantly higher than that of micron Al particles, and the thermal reaction properties exhibit notable distinctions. Following the previous studies on micron Al particles, the shell-breaking response of Al nanoparticles under vacuum conditions was analyzed using COMSOL simulation. Relationships between thermal stabilization time, shell-breaking cause, shell-breaking response time, and particle size were obtained, and a systematic analysis of the differences between micrometer and nanometer-sized particles was conducted. The results indicate that the thermal stabilization time of both micrometer and nanometer particles increases with the enlargement of particle size. The stress generated by heating Al nanoparticles with sizes ranging from 25–100 nm is insufficient to rupture the outer shell. For particles within the size range of 200 nm to 70 μm, the primary cause of shell-breaking is compressive stress overload, while particles in the range of 80–100 μm experience shell rupture primarily due to tensile stress overload. These results provide an important basis for understanding the shell-breaking mechanism of microns and nanoparticles of Al and studying the oxidation mechanism.

7 May 2025 in Fire
Verified
Journal Article
Open access
PDF file
HJHuiling Jiang
Huiling Jiang
JTJie Teng
Jie Teng
DWDong Wang
Dong Wang
LZLiang Zhou
Liang Zhou
YCYirui Chen
Yirui Chen
The Wan’an Bridge, the longest wooden lounge bridge in China with a history of more than 900 years, was devastated by a catastrophic fire in 2022. This tragic event underscores the susceptibility of historical wooden structures to fire damage. In this article, the bridge’s intricate structure and the development of the fire incident are introduced in detail. To gain a deeper insight into the patterns of fire propagation across the bridge and assess the reliability of fire simulations in predicting fire spread in historical wooden structures, we utilized the Fire Dynamics Simulator (FDS), with a sophisticated pyrolysis model and thermal response parameters specifically tailored to ancient fir wood. The modeling results reveal that the FDS simulation reflects the actual fire spread process well. Both the investigation and simulation findings indicate that once the flame reaches above the bridge deck, it enters a rapid three-dimensional propagation phase that is exceptionally challenging to control. Furthermore, the modeling results suggest that the application of intumescent fire-retardant coatings can significantly delay fire spread, reduce heat release rates, and suppress smoke production, thereby making them an effective fire prevention measure for historical wooden buildings.

12 February 2026 in Fire
Verified
Journal Article
Open access
PDF file
LZLiang Zhou
Liang Zhou
MHManman Hou
Manman Hou
ZZZheng Zeng
Zheng Zeng
JZJingyi Zhao
Jingyi Zhao
Chi-Min ShuChi-Min Shu
Chi-Min Shu
HJHuiling Jiang
Huiling Jiang
Arc fault is the dominant cause of fire in photovoltaic (PV) systems, making its accurate identification crucial for PV fire prevention. This study investigates the influence of voltage (200, 300, and 400 V) and current (3, 5, 7, 9, and 11 A) on the DC series arc fault characteristics in PV systems obtained through experimental analysis. The results show that voltage variation has a negligible impact on arc fault behavior, while higher current levels substantially increase noise in the arc fault signals. To effectively mitigate noise, this paper proposes a denoising method that combines an improved moss growth optimization algorithm (IMGO) with improved complete ensemble empirical mode decomposition featuring adaptive noise (ICEEMDAN). It is found that the IMGO-ICEEMDAN denoising algorithm can effectively diminish noise in current signals, broaden characteristic frequency bands, and ameliorate arc feature discernibility. Subsequently, an integrated multi-scale spatiotemporal model is developed to extract arc fault features from the denoised signals. The model employs wide deep convolutional neural networks (WDCNNs) and bidirectional long short-term memory (BiLSTM) networks for parallel feature extraction, supplemented by a cross-attention (CA) module to optimize feature integration. The proposed WDCNN-BiLSTM-CA model ultimately achieves a detection accuracy of 99.89%, demonstrating superior detection performance over conventional methods, such as CNN-GRU and 1DCNN-LSTM models. This work provides a reliable framework for arc fault detection and fire risk reduction in PV systems.