Stroke is one of the important causes of both disability and death worldwide, which is very common in older adults. Post-stroke cognitive impairment (PSCI) is a common secondary damage of stroke, which is the main cause of long-term disability and decreased quality of life in stroke patients, which brings a heavy burden to society and families. Acupuncture, as one of the oldest and widely used worldwide techniques in Chinese medicine, is recommended by the World Health Organization (WHO) as an alternative and complementary strategy for improving stroke care. This review comprehensively summarizes literature from the last 25 years, showing that acupuncture can exert strong beneficial effect on PSCI. The mechanisms of acupuncture on PSCI involves anti-neuronal apoptosis, promoting synaptic plasticity, alleviating central and peripheral inflammatory reactions, and regulating brain energy metabolism disorders (including improving cerebral blood flow, glucose utilization and mitochondrial structure and function, etc.), etc. The effects and mechanisms of acupuncture on PSCI reviewed in this study provides scientific and reliable evidence for acupuncture application for PSCI.
Fire is one of the most common and harmful disasters in real life. In 2021, firefighting teams in China reported 748,000 fires, resulting in 1987 deaths, 2225 injuries and CNY 6.75 billion of direct property losses, which account for 0.05‰ of GDP. Scientific and accurate estimation of evacuation time can provide decision support for intelligent fire evacuation. This paper aims to effectively improve the evacuation efficiency of people in large buildings, especially for a scenario with intricate evacuation passages. There are many factors that make a difference in evacuation time, such as individual behavior, occupant density, exit width, and so on. The people distribution density is introduced to effectively assess the impact of unstable pedestrian flow and unbalanced distribution in the process of evacuation. The verification results show that there is a strong positive correlation between people distribution density and evacuation time. Combining the people distribution density with many other factors, the training dataset is built by Pathfinder to learn the relationship between evacuation time and influencing factors. Finally, an evacuation time prediction model is established to estimate the consumption time that occupants spend on moving in the evacuation process based on stacking integration. The model can assist occupants in choosing different channels for evacuation in advance. After testing, the average error between the predicted evacuation consumption time and the reference time is 3.63 s. The result illustrates that the model can accurately predict the time consumed in the process of evacuation.
The Wan’an Bridge, the longest wooden lounge bridge in China with a history of more than 900 years, was devastated by a catastrophic fire in 2022. This tragic event underscores the susceptibility of historical wooden structures to fire damage. In this article, the bridge’s intricate structure and the development of the fire incident are introduced in detail. To gain a deeper insight into the patterns of fire propagation across the bridge and assess the reliability of fire simulations in predicting fire spread in historical wooden structures, we utilized the Fire Dynamics Simulator (FDS), with a sophisticated pyrolysis model and thermal response parameters specifically tailored to ancient fir wood. The modeling results reveal that the FDS simulation reflects the actual fire spread process well. Both the investigation and simulation findings indicate that once the flame reaches above the bridge deck, it enters a rapid three-dimensional propagation phase that is exceptionally challenging to control. Furthermore, the modeling results suggest that the application of intumescent fire-retardant coatings can significantly delay fire spread, reduce heat release rates, and suppress smoke production, thereby making them an effective fire prevention measure for historical wooden buildings.
Arc fault is the dominant cause of fire in photovoltaic (PV) systems, making its accurate identification crucial for PV fire prevention. This study investigates the influence of voltage (200, 300, and 400 V) and current (3, 5, 7, 9, and 11 A) on the DC series arc fault characteristics in PV systems obtained through experimental analysis. The results show that voltage variation has a negligible impact on arc fault behavior, while higher current levels substantially increase noise in the arc fault signals. To effectively mitigate noise, this paper proposes a denoising method that combines an improved moss growth optimization algorithm (IMGO) with improved complete ensemble empirical mode decomposition featuring adaptive noise (ICEEMDAN). It is found that the IMGO-ICEEMDAN denoising algorithm can effectively diminish noise in current signals, broaden characteristic frequency bands, and ameliorate arc feature discernibility. Subsequently, an integrated multi-scale spatiotemporal model is developed to extract arc fault features from the denoised signals. The model employs wide deep convolutional neural networks (WDCNNs) and bidirectional long short-term memory (BiLSTM) networks for parallel feature extraction, supplemented by a cross-attention (CA) module to optimize feature integration. The proposed WDCNN-BiLSTM-CA model ultimately achieves a detection accuracy of 99.89%, demonstrating superior detection performance over conventional methods, such as CNN-GRU and 1DCNN-LSTM models. This work provides a reliable framework for arc fault detection and fire risk reduction in PV systems.