Shengwei Xiong

Dr. Shengwei Xiong

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2022 in Journal of Urology
Verified
Journal Article
Open access
SFShubo Fan
Shubo Fan
ZZZhongyuan Zhang
Zhongyuan Zhang
JWJie Wang
Jie Wang
SXShengwei Xiong
Shengwei Xiong
XDXiaofei Dai
Xiaofei Dai
LZLiqun Zhou
Liqun Zhou
Our goal was to evaluate the feasibility, safety and effectiveness of the KangDuo Surgical Robot-01 (KD-SR-01) system for robot-assisted radical prostatectomy (RARP). This prospective, single-center, single-arm clinical study was conducted from May 2021 to August 2021. Sixteen RARP procedures with the KD-SR-01 system were performed by 1 surgeon. The perioperative and followup data were prospectively recorded. Early oncologic outcomes were assessed according to surgical margin status and continence was defined as no more than 1 pad daily or urine leakage of ≤20 gm by the 24-hour pad weight test. Ergonomics were assessed with the NASA-TLX (National Aeronautics and Space Administration Task Load Index). All cases were completed successfully without conversion to traditional RARP, laparoscopic surgery or open surgery. The median docking time, console time and urethrovesical anastomosis time were 5.9 (range, 2.5-11.5), 87 (range, 70-120) and 14.4 minutes (range, 12.0-25.7), respectively. The median estimated blood loss was 50 ml (range, 10-200). None of patients required intraoperative transfusion. The median postoperative hospital stay was 5 days (range, 4-10). Overall, a positive surgical margin occurred in 4 (25%) patients. No biochemical recurrence occurred within 1 month after surgery. The continence rate was 87.5% (14/16) at 1 month after catheter removal. No severe intraoperative or postoperative complications (Clavien-Dindo grade ≥3) occurred. The surgeon reported a high comfort level with a NASA-TLX global score of 22.7±3.2. The KD-SR-01 system is feasible, safe and effective for management of localized prostate cancer.

1 August 2020 in Journal of Endourology
Verified
Journal Article
Closed access
JWJie Wang
Jie Wang
SXShengwei Xiong
Shengwei Xiong
SFShubo Fan
Shubo Fan
KYKunlin Yang
Kunlin Yang
BHBingwei Huang
Bingwei Huang
XLXuesong Li
Xuesong Li
Purpose: To evaluate the onlay technique using the appendix for ureteral reconstruction and describe the initial experience of nine operations performed by one surgeon. Methods: Nine patients with complex ureteral strictures who underwent appendiceal onlay flap ureteroplasty since May 2019 were recruited from our RECUTTER database. There were seven men and two women, with a mean age of 38.9 years; four patients underwent robot-assisted laparoscopic surgery, and five patients underwent traditional laparoscopic surgery. All patients had iatrogenic injuries of the ureter after treatment of stone disease. Seven patients had proximal ureteral strictures, and two had midureteral strictures. The mean stricture length of the nine patients was 3.9 (range 3–4.5) cm. Nephrostomy was performed in seven patients before they presented to our center, and the other two patients had indwelling Double-J ureteral stents. Results: All nine operations were effectively completed without open conversion. The mean operation time was 182 (range 135–220) minutes, the mean estimated blood loss was 71 (range 20–100) mL, and the mean length of postoperative hospital stay was 9 (range 6–12) days. No postoperative complications of high grade (Clavien–Dindo III and IV) occurred within 30 days of surgery. All the patients had their Double-J ureteral stents and nephrostomy tubes removed after complete ureteroscopy and upper urinary tract urodynamic examination or CTU, which showed that the anastomosis healed well and that the urinary tract was unobstructed, respectively. The objective success rate was 100% (all the patients had endoscopic and radiographic resolution of their ureteral strictures). The subjective success rate was 88.9% (one patient developed recurrent back discomfort and a 0.5 cm calculus was found in her renal pelvis). Conclusions: Appendiceal onlay flap ureteroplasty is a viable and effective technique for treating complex proximal and middle ureteral strictures at the right side.

16 March 2021 in BJU International
Verified
Journal Article
Closed access
PDF file
SFShubo Fan
Shubo Fan
XDXiaofei Dai
Xiaofei Dai
KYKunlin Yang
Kunlin Yang
SXShengwei Xiong
Shengwei Xiong
GXGengyan Xiong
Gengyan Xiong
XLXuesong Li
Xuesong Li

1 May 2023 in Journal of Endourology
Verified
Journal Article
Open access
SFShubo Fan
Shubo Fan
HHHan Hao
Han Hao
SCSilu Chen
Silu Chen
JWJie Wang
Jie Wang
XDXiaofei Dai
Xiaofei Dai
XLXuesong Li
Xuesong Li
Objective: To compare the efficacy and safety of robot-assisted laparoscopic radical prostatectomy (RARP) performed using the KangDuo surgical robot system to the da Vinci Si robotic system in clinically localized prostate cancer (KD-RARP vs DV-RARP). Methods: A total of 16 patients underwent extraperitoneal KD-RARP performed by a single experienced surgeon using the KangDuo surgical robot system between May 2021 and August 2021. The data were prospectively collected. The most recent 16 cases of extraperitoneal DV-RARP performed in 2021 by the same surgeon were selected from a prospectively maintained database for comparison to prevent operator variability. Preoperative, perioperative, and postoperative data were collected and compared between the two groups. Results: No significant difference was noted between the two groups in terms of basic clinical characteristics. All operations were performed successfully without open or traditional laparoscopic conversion. KD-RARP had a significantly longer operation time compared with DV-RARP (127 [107–159] vs 70.5 [54–90] minutes, p < 0.001). No significant differences between the two groups were observed in neurovascular bundle sparing, estimated blood loss, postoperative hospital stay duration, complications, positive surgical margins, biochemical recurrence, and continence recovery 3 months after catheter removal. Conclusions: RARP using the KangDuo surgical robot system achieved similar short-term oncological and functional outcomes with a disadvantage in operation time compared with the da Vinci Si robotic system. A multicenter randomized clinical trial with a larger sample size is needed for more experience.

1 January 2020 in BioMed Research International
Verified
Journal Article
Open access
PDF file
SXShengwei Xiong
Shengwei Xiong
JWJie Wang
Jie Wang
WZWeijie Zhu
Weijie Zhu
KYKunlin Yang
Kunlin Yang
GDGuangpu Ding
Guangpu Ding
DEDaniel D Eun
Daniel D Eun
Ureteroplasty using onlay grafts or flaps emerged as an innovative procedure for the management of proximal and midureteral strictures. Autologous grafts or flaps used commonly in ureteroplasty include the oral mucosae, bladder mucosae, ileal mucosae, and appendiceal mucosae. Oral mucosa grafts, especially buccal mucosa grafts (BMGs), have gained wide acceptance as a graft choice for ureteroplasty. The reported length of BMG ureteroplasty ranged from 1.5 to 11 cm with success rates of 71.4%‐100%. However, several studies have demonstrated that ureteroplasty using lingual mucosa grafts yields better recipient site outcomes and fewer donor site complications than that using BMGs. In addition, there is no essential difference in the efficacy and complication rates of BMG ureteroplasty using an anterior approach or a posterior approach. Intestinal graft or flap ureteroplasty was also reported. And the reported length of ileal or appendiceal flap ureteroplasty ranged from 1 to 8 cm with success rates of 75%‐100%. Moreover, the bladder mucosa, renal pelvis wall, and penile/preputial skin have also been reported to be used for ureteroplasty and have achieved satisfactory outcomes, but each graft or flap has unique advantages and potential problems. Tissue engineering‐based ureteroplasty through the implantation of patched scaffolds, such as the small intestine submucosa, with or without cell seeding, has induced successful ureteral regeneration structurally close to that of the native ureter and has resulted in good functional outcomes in animal models.

1 December 2022 in Journal of Endourology
Verified
Journal Article
Closed access
SFShubo Fan
Shubo Fan
SXShengwei Xiong
Shengwei Xiong
ZLZhihua Li
Zhihua Li
KYKunlin Yang
Kunlin Yang
JWJie Wang
Jie Wang
LZLiqun Zhou
Liqun Zhou
Objective: To share our experience in robot-assisted pyeloplasty (RAP) with the Kangduo (KD) surgical robot vs. the da Vinci Si (DV) robotic system (KD-RAP vs. DV-RAP, respectively). Methods: From August 2019 to February 2021, 16 patients with ureteropelvic junction obstruction (UPJO) underwent KD-RAP and other 16 patients with UPJO accepted DV-RAP. All procedures were performed by the same surgeon. The perioperative results and follow-up data were prospectively collected and compared. Results: There was no conversion to open or laparoscopic surgery. The mean operation time was significantly longer in the KD-RAP group than the DV-RAP group (141 ± 28 vs. 118 ± 31 min, respectively, p = 0.04). The time per stitch was significantly longer in the KD-RAP group than the DV-RAP group (1.7 ± 0.5 vs. 1.4 ± 0.3 min, respectively, p = 0.05). No significant difference was noted in the estimated blood loss and the postoperative length of hospitalization. At a median follow-up of 19 (range, 17–21) and 19.5 (range, 14–33) months for the KD-RAP and DV-RAP groups respectively, no difference was noted in the success rates between the KD-RAP and DV-RAP groups (93.75% and 100%, respectively; p = 0.31). Complications were comparable between the two groups (p = 0.54). One (6.3%) patient developed urinary infection which responded well to oral antibiotics in KD-RAP group and 2 (12.5%) patients suffered from irritation symptoms of bladder which improved after removal of D-J stent in DV-RAP group. Conclusion: The RAP with the use of the KD system was feasible, safe and effective. The DV-RAP group showed advantage in the operation time and the time per stitch.