Eddy Krueger

Prof. Dr. Eddy Krueger

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2023 in Electronics
Verified
Journal Article
Open access
PDF file
JJJose Jair Alves Mendes Junior
Jose Jair Alves Mendes Junior
DCDaniel Campos
Daniel Campos
LBLorenzo Coelho de Andrade Villela De Biassio
Lorenzo Coelho de Andrade Villela De Biassio
PPPedro Carlin Passos
Pedro Carlin Passos
PJPaulo BRONIERA Broniera Junior
Paulo BRONIERA Broniera Junior
EKEddy Krueger
Eddy Krueger
Acquiring biopotentials with fidelity using low-cost circuits is a significant challenge in biomedical instrumentation. In this perspective, our goal is to investigate the characteristics of the widely applied AD8232®, an analog front-end for biopotential acquisition. We designed and evaluated circuits to acquire the most common biosignals: electrocardiogram (ECG), electromyogram (EMG), and electroencephalogram (EEG). Our findings show that the circuit is suitable for ECG and EMG instrumentation, although it has limitations for EEG signals, particularly concerning the gain. The entire project of the boards is also a contribution of this work as we intend to corroborate open-source do-it-yourself biomedical instrumentation.

1 December 2014 in Research on Biomedical Engineering
Verified
Journal Article
Open access
PDF file
EKEddy Krueger
Eddy Krueger
ESEduardo Mendonça Scheeren
Eduardo Mendonça Scheeren
GNGuilherme Nunes Nogueira-Neto
Guilherme Nunes Nogueira-Neto
VBVera Lúcia da Silveira Nantes Button
Vera Lúcia da Silveira Nantes Button
PNPercy Nohama
Percy Nohama
INTRODUCTION: The evaluation of muscular tissue condition can be accomplished with mechanomyography (MMG), a technique that registers intramuscular mechanical waves produced during a fiber's contraction and stretching that are sensed or interfaced on the skin surface. OBJECTIVE: Considering the scope of MMG measurements and recent advances involving the technique, the goal of this paper is to discuss mechanomyography updates and discuss its applications and potential future applications. METHODS: Forty-three MMG studies were published between the years of 1987 and 2013. RESULTS: MMG sensors are developed with different technologies such as condenser microphones, accelerometers, laser-based instruments, etc. Experimental protocols that are described in scientific publications typically investigated the condition of the vastus lateralis muscle and used sensors built with accelerometers, third and fourth order Butterworth filters, 5-100Hz frequency bandpass, signal analysis using Root Mean Square (RMS) (temporal), Median Frequency (MDF) and Mean Power Frequency (MPF) (spectral) features, with epochs of 1 s. CONCLUSION: Mechanomyographic responses obtained in isometric contractions differ from those observed during dynamic contractions in both passive and functional electrical stimulation evoked movements. In the near future, MMG features applied to biofeedback closed-loop systems will help people with disabilities, such as spinal cord injury or limb amputation because they may improve both neural and myoelectric prosthetic control. Muscular tissue assessment is a new application area enabled by MMG; it can be useful in evaluating the muscular tonus in anesthetic blockade or in pathologies such as myotonic dystrophy, chronic obstructive pulmonary disease, and disorders including dysphagia, myalgia and spastic hypertonia. New research becomes necessary to improve the efficiency of MMG systems and increase their application in rehabilitation, clinical and other health areas.

1 August 2007 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
EKEddy Krueger
Eddy Krueger
JPJ.O. Perry
J.O. Perry
YWY. Wu
Y. Wu
VHV.M. Haughton
V.M. Haughton
BACKGROUND AND PURPOSE: By calculating T2 relaxation times for intervertebral disks, we tested the hypothesis that disk water concentration increases between the first and second decades of life.

1 September 2014 in Fisioterapia em Movimento
Verified
Journal Article
Open access
PDF file
EKEddy Krueger
Eddy Krueger
JJJosé Luiz Claudino Junior
José Luiz Claudino Junior
ESEduardo Scheeren
Eduardo Scheeren
Eduardo Borba NevesEduardo Borba Neves
Eduardo Borba Neves
EMEduardo Mulinari
Eduardo Mulinari
PNPercy Nohama
Percy Nohama
Introduction Iontophoresis is a noninvasive technique used to increase transdermal penetration of substances through the skin layer (epidermis, dermis and hypodermis) in a controlled manner. Technological advance in recent decades have provided reduced cost of equipment needed for implementation, which allowed for the expansion of this technique. Objective The aim of this paper is to present the state of the art on iontophoresis, ranging from the atomic characteristics of the ion formation to the current applications of the technique. Methods Were researched papers from databases: IOP publishing, ScienceDirect, Pubmed, Springer, IEEE Xplore, Google Scholar and books with keywords iontophoresis, ions, topical applications between 1967 and 2010. Results Were selected (number of papers and database) 1 IOP Publishing, 1 from ScienceDirect, Central, 1 from Springer, 2 from PubMed, 11 from IEEE Xplore, 35 from Google Scholar, and 15 books, totaling 66 references and websites with nationally marketed electrotherapy products. Conclusion Iontophoresis is suitable for applications such as acetic acid (calcific tendinitis and myositis ossificans), calcium chloride and magnesium sulfate (control of musculoskeletal spasms), dexamethasone (inflammation), lidocaine (inflammation of soft tissues), zinc oxide (rheumatoid arthritis). It is also used in cosmetic applications with devices attached to the skin and for eye treatment aimed at specific tissues of the eye, providing a treatment option for various eye diseases, reducing the complications secondary to traditional methods of treatment. The advantages are the significant increase in the release and control of therapeutic agents, including drugs with high molecular weight. The disadvantages of iontophoresis are the complexity of the drug release system and prolonged exposure of the skin to an electrical current.

1 March 2019 in Neuroscience Letters
Verified
Journal Article
Open access
EKEddy Krueger
Eddy Krueger
LML.M.S. Magri
L.M.S. Magri
ABA.S. Botelho
A.S. Botelho
FBF.S. Bach
F.S. Bach
CRC.L.K. Rebellato
C.L.K. Rebellato
LPLana Popovic-Maneski
Lana Popovic-Maneski
The application of low-intensity electrical stimulation (LIES) to neural tissue increases neurochemical factors responsible for regeneration as nerve growth factor. Stem cell (SC) therapy for patients with Spinal cord injury (SCI) promote some increase functional improvement. Investigate the electromyographic response in paraplegic dogs undergoing LIES and SC transplantation. 27 dogs paraplegics with SCI were divided into three groups with different types of therapy. GADSC: two SC transplants (n = 9); GLIES: LIES (n = 8); GCOMB: two SC transplants and LIES (n = 10). Adipose derived mesenchymal stem cells (ADSCs) were transplanted by lumbar puncture in the amount of 1.2 × 106 cells/50 μL. Acupuncture needles positioned in the interspinous space were used for stimulation. The electrical stimulation was applied with a mean voltage ∼30 mV and four consecutive modulated frequencies (5 Hz, 10 Hz, 15 Hz and 20 Hz) within 5 min each. The patients motor performance was evaluated before (Pre) the procedure and after 30 (Post30) and 60 (Post60) days, from electromyography root mean square (EMGRMS) registered with subcutaneous electrodes in the vastus lateralis muscle, while the animals were in quadrupedal position. All three groups showed a significant intra-group increase of EMGRMS (Pre vs. Post30 or Pre vs. Post60). However, there were no statistically significant differences between Post30 and Post60. The inter-group test (GADSC X GLIES X GCOMB) did not present significance when compared the instants Pre (p = 0.34), Post30 (p = 0.78) and Post60 (p = 0.64). Some dogs recovered motor activity, expressed by the EMGRMS, in all groups, in pre vs. post (30 or 60 days) comparisons.

1 August 2012
Verified
Conference Paper
Closed access
EKEddy Krueger
Eddy Krueger
ESEduardo Scheeren
Eduardo Scheeren
GNGuilherme N. Nogueira-Neto
Guilherme N. Nogueira-Neto
VBVera Lúcia da S. N. Button
Vera Lúcia da S. N. Button
PNPercy Nohama
Percy Nohama
Several pathologies can cause muscle spasticity. Modified Ashworth scale (MAS) can rank spasticity, however its results depend on the physician subjective evaluation. This study aims to show a new approach to spasticity assessment by means of MMG analysis of hamstrings antagonist muscle group (quadriceps muscle). Four subjects participated in the study, divided into two groups regarding MAS (MAS0 and MAS1). MMG sensors were positioned over the muscle belly of rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM) muscles. The range of movement was acquired with an electrogoniometer placed laterally to the knee. The system was based on a LabVIEW acquisition program and the MMG sensors were built with triaxial accelerometers. The subjects were submitted to stretching reflexes and the integral of the MMG (MMG INT ) signal was calculated to analysis. The results showed that the MMG INT was greater to MAS1 than to MAS0 [muscle RF (p= 0.004), VL (p= 0.001) and VM (p= 0.007)]. The results showed that MMG was viable to detect a muscular tonus increase in antagonist muscular group (quadriceps femoris) of spinal cord injured volunteers.