Yijing Wu

Yijing Wu

Auto-generated profile, based on publicly available information

Yijing Wu

From the Departments of Medical Physics (Y.W., G.S., C.A.H., C.A.M., M.A.S.).

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
KNK. Niu
K. Niu
PYP. Yang
P. Yang
YWY. Wu
Y. Wu
TST. Struffert
T. Struffert
ADA. Doerfler
A. Doerfler
GCG.- H. Chen
G.- H. Chen
BACKGROUND AND PURPOSE: Perfusion imaging in the angiography suite may provide a way to reduce time from stroke onset to endovascular revascularization of patients with large-vessel occlusion. Our purpose was to compare conebeam CT perfusion with multidetector CT perfusion. MATERIALS AND METHODS: Data from 7 subjects with both multidetector CT perfusion and conebeam CT perfusion were retrospectively processed and analyzed. Two algorithms were used to enhance temporal resolution and temporal sampling density and reduce the noise of conebeam CT data before generating perfusion maps. Two readers performed qualitative image-quality evaluation on maps by using a 5-point scale. ROIs indicating CBF/CBV abnormalities were drawn. Quantitative analyses were performed by using the Sørensen-Dice coefficients to quantify the similarity of abnormalities. A noninferiority hypothesis was tested to compare conebeam CT perfusion against multidetector CT perfusion. RESULTS: Average image-quality scores for multidetector CT perfusion and conebeam CT perfusion images were 2.4 and 2.3, respectively. The average confidence score in diagnosis was 1.4 for both multidetector CT and conebeam CT; the average confidence scores for the presence of a CBV/CBF mismatch were 1.7 (κ = 0.50) and 1.5 (κ = 0.64). For multidetector CT perfusion and conebeam CT perfusion maps, the average scores of confidence in making treatment decisions were 1.4 (κ = 0.79) and 1.3 (κ = 0.90). The area under the visual grading characteristic for the above 4 qualitative quality scores showed an average area under visual grading characteristic of 0.50, with 95% confidence level cover centered at the mean for both readers. The Sørensen–Dice coefficient for CBF maps was 0.81, and for CBV maps, 0.55. CONCLUSIONS: After postprocessing methods were applied to enhance image quality for conebeam CT perfusion maps, the conebeam CT perfusion maps were not inferior to those generated from multidetector CT perfusion.

13 September 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
YWY. Wu
Y. Wu
GSG. Shaughnessy
G. Shaughnessy
CHC.A. Hoffman
C.A. Hoffman
EOE.L. Oberstar
E.L. Oberstar
SSS. Schafer
S. Schafer
MSM.A. Speidel
M.A. Speidel
BACKGROUND AND PURPOSE: 4D-DSA provides time-resolved 3D-DSA volumes with high temporal and spatial resolutions. The purpose of this study is to investigate a shifted least squares method to estimate the blood velocity from the 4D DSA images. Quantitative validation was performed using a flow phantom with an ultrasonic flow probe as ground truth. Quantification of blood velocity in human internal carotid arteries was compared with measurements generated from 3D phase-contrast MR imaging. MATERIALS AND METHODS: The centerlines of selected vascular segments and the time concentration curves of each voxel along the centerlines were determined from the 4D-DSA dataset. The temporal shift required to achieve a minimum difference between any point and other points along the centerline of a segment was calculated. The temporal shift as a function of centerline point position was fit to a straight line to generate the velocity. The proposed shifted least-squares method was first validated using a flow phantom study. Blood velocities were also estimated in the 14 ICAs of human subjects who had both 4D-DSA and phase-contrast MR imaging studies. Linear regression and correlation analysis were performed on both the phantom study and clinical study, respectively. RESULTS: Mean velocities of the flow phantom calculated from 4D-DSA matched very well with ultrasonic flow probe measurements with 11% relative root mean square error. Mean blood velocities of ICAs calculated from 4D-DSA correlated well with phase-contrast MR imaging measurements with Pearson correlation coefficient r = 0.835. CONCLUSIONS: The availability of 4D-DSA provides the opportunity to use the shifted least-squares method to estimate velocity in vessels within a 3D volume.

1 August 2007 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
EKEddy Krueger
Eddy Krueger
JPJ.O. Perry
J.O. Perry
YWY. Wu
Y. Wu
VHV.M. Haughton
V.M. Haughton
BACKGROUND AND PURPOSE: By calculating T2 relaxation times for intervertebral disks, we tested the hypothesis that disk water concentration increases between the first and second decades of life.

11 March 2010 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
YWY. Wu
Y. Wu
WCW. Chang
W. Chang
KJK.M. Johnson
K.M. Johnson
JVJ. Velikina
J. Velikina
HRH. Rowley
H. Rowley
PTP. Turski
P. Turski
SUMMARY: We report on the image quality obtained by using fast contrast-enhanced whole-brain 4D radial MRA with 0.75-second temporal resolution, isotropic submillimeter spatial resolution, and velocity encoding (HYPRFlow). Images generated by HYPR-LR by using the velocity-encoded data as the constraining image were of diagnostic quality. In addition, we demonstrate that measurements of shear stress within the middle cerebral artery can be derived from the high-resolution 3D velocity data.

30 November 2004 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
YWYijing Wu
Yijing Wu
KGK. Craig Goodrich
K. Craig Goodrich
HBHenry R. Buswell
Henry R. Buswell
GKGregory L. Katzman
Gregory L. Katzman
DPDennis L. Parker
Dennis L. Parker

26 January 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
PYP. Yang
P. Yang
KNK. Niu
K. Niu
YWY. Wu
Y. Wu
TST. Struffert
T. Struffert
ADA. Doerfler
A. Doerfler
GCG.-H. Chen
G.-H. Chen
BACKGROUND AND PURPOSE: The assessment of collaterals and clot burden in patients with acute ischemic stroke provides important information about treatment options and clinical outcome. Time-resolved C-arm conebeam CT angiography has the potential to provide accurate and reliable evaluations of collaterals and clot burden in the angiographic suite. Experience with this technique is extremely limited, and feasibility studies are needed to validate this technique. Our purpose was to present such a feasibility study. MATERIALS AND METHODS: Ten C-arm conebeam CT perfusion datasets from 10 subjects with acute ischemic stroke acquired before endovascular treatment were retrospectively processed to generate time-resolved conebeam CTA. From time-resolved conebeam CTA, 2 experienced readers evaluated the clot burden and collateral flow in consensus by using previously reported scoring systems and assessed the clinical value of this novel imaging technique independently. Interobserver agreement was analyzed by using the intraclass correlation analysis method. RESULTS: Clot burden and collateral flow can be assessed by using the commonly accepted scoring systems for all eligible cases. Additional clinical information (eg, the quantitative dynamic information of collateral flow) can be obtained from this new imaging technique. Two readers agreed that time-revolved C-arm conebeam CTA is the preferred method for evaluating the clot burden and collateral flow compared with other conventional imaging methods. CONCLUSIONS: Comprehensive evaluations of clot burden and collateral flow are feasible by using time-resolved C-arm conebeam CTA data acquired in the angiography suite. This technique further enriches the imaging tools in the angiography suite to enable a “one-stop- shop” imaging workflow for patients with acute ischemic stroke.