Representative Publications

View All Publications
29 December 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
STSirisha Tadimalla
Sirisha Tadimalla
KMKonstantin I. Momot
Konstantin I. Momot
Anisotropy of transverse proton spin relaxation in collagen-rich tissues like cartilage and tendon is a well-known phenomenon that manifests itself as the “magic-angle” effect in magnetic resonance images of these tissues. It is usually attributed to the non-zero averaging of intra-molecular dipolar interactions in water molecules bound to oriented collagen fibers. One way to manipulate the contributions of these interactions to spin relaxation is by partially replacing the water in the cartilage sample with deuterium oxide. It is known that dipolar interactions in deuterated solutions are weaker, resulting in a decrease in proton relaxation rates. In this work, we investigate the effects of deuteration on the longitudinal and the isotropic and anisotropic contributions to transverse relaxation of water protons in bovine articular cartilage. We demonstrate that the anisotropy of transverse proton spin relaxation in articular cartilage is independent of the degree of deuteration, bringing into question some of the assumptions currently held over the origins of relaxation anisotropy in oriented tissues.

28 November 2022 in Cancers
Verified
Journal Article
Open access
PDF file
STSirisha Tadimalla
Sirisha Tadimalla
WWWei Wang
Wei Wang
AHAnnette Haworth
Annette Haworth
Stereotactic body radiation therapy (SBRT) is an emerging treatment for liver cancers whereby large doses of radiation can be delivered precisely to target lesions in 3–5 fractions. The target dose is limited by the dose that can be safely delivered to the non-tumour liver, which depends on the baseline liver functional reserve. Current liver SBRT guidelines assume uniform liver function in the non-tumour liver. However, the assumption of uniform liver function is false in liver disease due to the presence of cirrhosis, damage due to previous chemo- or ablative therapies or irradiation, and fatty liver disease. Anatomical information from magnetic resonance imaging (MRI) is increasingly being used for SBRT planning. While its current use is limited to the identification of target location and size, functional MRI techniques also offer the ability to quantify and spatially map liver tissue microstructure and function. This review summarises and discusses the advantages offered by functional MRI methods for SBRT treatment planning and the potential for adaptive SBRT workflows.

27 February 2022 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
STSirisha Tadimalla
Sirisha Tadimalla
DWDaniel J. Wilson
Daniel J. Wilson
DSDavid Shelley
David Shelley
GBGavin Bainbridge
Gavin Bainbridge
MSMargaret Saysell
Margaret Saysell
SSSteven P. Sourbron
Steven P. Sourbron
Background: Three‐dimensional variable flip angle (VFA) methods are commonly used for T1 mapping of the liver, but there is no data on the accuracy, repeatability, and reproducibility of this technique in this organ in a multivendor setting.Purpose: To measure bias, repeatability, and reproducibility of VFA T1 mapping in the liver.Study Type: Prospective observational.Population: Eight healthy volunteers, four women, with no known liver disease.Field Strength/Sequence: 1.5‐T and 3.0‐T; three‐dimensional steady‐state spoiled gradient echo with VFAs; Look‐Locker.Assessment: Traveling volunteers were scanned twice each (30 minutes to 3 months apart) on six MRI scanners from three vendors (GE Healthcare, Philips Medical Systems, and Siemens Healthineers) at two field strengths. The maximum period between the first and last scans among all volunteers was 9 months. Volunteers were instructed to abstain from alcohol intake for at least 72 hours prior to each scan and avoid high cholesterol foods on the day of the scan.Statistical Tests: Repeated measures ANOVA, Student t‐test, Levene's test of variances, and 95% significance level. The percent error relative to literature liver T1 in healthy volunteers was used to assess bias. The relative error (RE) due to intrascanner and interscanner variation in T1 measurements was used to assess repeatability and reproducibility.Results: The 95% confidence interval (CI) on the mean bias and mean repeatability RE of VFA T1 in the healthy liver was 34 ± 6% and 10 ± 3%, respectively. The 95% CI on the mean reproducibility RE at 1.5 T and 3.0 T was 29 ± 7% and 25 ± 4%, respectively.Data Conclusion: Bias, repeatability, and reproducibility of VFA T1 mapping in the liver in a multivendor setting are similar to those reported for breast, prostate, and brain.Level of Evidence: 1Technical Efficacy Stage: 1

1 June 2019 in Magnetic Resonance Imaging
Verified
Journal Article
Open access
John WatertonJohn Waterton
John Waterton
CHCatherine D.G. Hines
Catherine D.G. Hines
PHPaul Hockings
Paul Hockings
ILIina Laitinen
Iina Laitinen
SZSabina Ziemian
Sabina Ziemian
GSGunnar Schütz
Gunnar Schütz
Background: Many translational MR biomarkers derive from measurements of the water proton longitudinal relaxation rate R-1, but evidence for between-site reproducibility of R-1 in small-animal MRI is lacking. Objective: To assess R-1 repeatability and multi-site reproducibility in phantoms for preclinical MRI. Methods: R-1 was measured by saturation recovery in 2% agarose phantoms with five nickel chloride concentrations in 12 magnets at 5 field strengths in 11 centres on two different occasions within 1-13 days. R-1 was analysed in three different regions of interest, giving 360 measurements in total. Root-mean-square repeatability and reproducibility coefficients of variation (CoV) were calculated. Propagation of reproducibility errors into 21 translational MR measurements and biomarkers was estimated. Relaxivities were calculated. Dynamic signal stability was also measured. Results: CoV for day-to-day repeatability (N = 180 regions of interest) was 2.34% and for between-centre reproducibility (N = 9 centres) was 1.43%. Mostly, these do not propagate to biologically significant between centre error, although a few R-1-based MR biomarkers were found to be quite sensitive even to such small errors in R-1, notably in myocardial fibrosis, in white matter, and in oxygen-enhanced MRI. The relaxivity of aqueous Ni2+ in 2% agarose varied between 0.66 s(-1) mM(-1) at 3 T and 0.94 s(-1) mM(-1) at 11.7T. Interpretation: While several factors affect the reproducibility of R-1-based MR biomarkers measured pre-clinically, between-centre propagation of errors arising from intrinsic equipment irreproducibility should in most cases be small. However, in a few specific cases exceptional efforts might be required to ensure R-1-reproducibility.

20 June 2017 in Biomedical Spectroscopy and Imaging
Verified
Journal Article
Closed access
PDF file
STSirisha Tadimalla
Sirisha Tadimalla
MTM.C. Tourell
M.C. Tourell
RKR. Knott
R. Knott
KMKonstantin I. Momot
Konstantin I. Momot
Collagen fibre architecture in articular cartilage is commonly described in terms of the predominant direction of fibre alignment. X-ray scattering has been used to study the distribution of fibre orientations in cartilage. In this paper, a new metho

4 September 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PHPetra J. van Houdt
Petra J. van Houdt
SRSudarshan Ragunathan
Sudarshan Ragunathan
MBMichael Berks
Michael Berks
ZAZaki Ahmed
Zaki Ahmed
LKLucy Kershaw
Lucy Kershaw
OGon behalf of the ISMRM Perfusion Study Group
on behalf of the ISMRM Perfusion Study Group
Purpose: Software has a substantial impact on quantitative perfusion MRI values. The lack of generally accepted implementations, code sharing and transparent testing reduces reproducibility, hindering the use of perfusion MRI in clinical trials. To address these issues, the ISMRM Open Science Initiative for Perfusion Imaging (OSIPI) aimed to establish a community‐led, centralized repository for sharing open‐source code for processing contrast‐based perfusion imaging, incorporating an open‐source testing framework.Methods: A repository was established on the OSIPI GitHub website. Python was chosen as the target software language. Calls for code contributions were made to OSIPI members, the ISMRM Perfusion Study Group, and publicly via OSIPI websites. An automated unit‐testing framework was implemented to evaluate the output of code contributions, including visual representation of the results.Results: The repository hosts 86 implementations of perfusion processing steps contributed by 12 individuals or teams. These cover all core aspects of DCE‐ and DSC‐MRI processing, including multiple implementations of the same functionality. Tests were developed for 52 implementations, covering five analysis steps. For T1 mapping, signal‐to‐concentration conversion and population AIF functions, different implementations resulted in near‐identical output values. For the five pharmacokinetic models tested (Tofts, extended Tofts‐Kety, Patlak, two‐compartment exchange, and two‐compartment uptake), differences in output parameters were observed between contributions.Conclusions: The OSIPI DCE‐DSC code repository represents a novel community‐led model for code sharing and testing. The repository facilitates the re‐use of existing code and the benchmarking of new code, promoting enhanced reproducibility in quantitative perfusion imaging.