Pietro Regazzoni

Dr. Pietro Regazzoni

AO Research Institute, Davos, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2007 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
FMFelix Matthews
Felix Matthews
DHDominik J Hoigne
Dominik J Hoigne
MWManfred Weiser
Manfred Weiser
GWGuido A Wanner
Guido A Wanner
Pietro RegazzoniPietro Regazzoni
Pietro Regazzoni
PMPeter Messmer
Peter Messmer
Objectives: During complex image-guided orthopedic trauma procedures, repetitive fluoroscopic scout imaging is performed. A number of preparatory positioning images often must be taken to reproduce a comparable projection. These scout images have no intrinsic clinical relevance but nevertheless expose the patient and the surgical team to considerable radiation, which could be avoided. This study presents and validates a method to decrease intraoperative radiation. Methods: Precision, time requirements, and number of scout images for repositioning the fluoroscope, with and without navigation aid, were recorded on 20 test-rig and 3 phantom setups. A commercially available image-guided surgical navigation system (Vector Vision®, BrainLAB), originally designed for instrument navigation, was employed to register and retrieve the C-arm positions. A newly developed software computed the necessary moves to reposition the C-arm on an intuitive visual display. Results: Retrieving a given C-arm position with the conventional non-navigated technique required an average of 7 scout images (range, 3 to 12 images). In contrast, navigation-assisted repositioning did not necessitate a single scout image. Deviations from the original projection were minimal for both navigated (0.9 degrees, 95% CI 0.8 to 1.1 degrees) and non-navigated repositioning (0.8 degrees, 95% CI 0.7 to 0.9 degrees). Average positioning times were comparable when navigating the C-arm (46 seconds, 95% CI 41 to 51 seconds) and in scout image-based positioning (49 seconds, 95% CI 44 to 53 seconds). Conclusions: Navigated C-arm positioning avoids multiple scout images and yields sufficient precision for clinical deployment. Radiation exposure can be reduced considerably by a combination of instrument navigation and navigated C-arm positioning.

1 June 2004 in Injury
Verified
Journal Article
Closed access
PDF file
PMPeter Messmer
Peter Messmer
TGThomas Gross
Thomas Gross
NSNorbert Suhm
Norbert Suhm
Pietro RegazzoniPietro Regazzoni
Pietro Regazzoni
AJAugustinus L. Jacob
Augustinus L. Jacob
RHRolf W. Huegli
Rolf W. Huegli

13 June 2012 in Journal of Orthopaedics and Traumatology
Verified
Journal Article
Open access
PDF file
FPF. del Prete
F. del Prete
TNT. Nizegorodcew
T. Nizegorodcew
Pietro RegazzoniPietro Regazzoni
Pietro Regazzoni
Background Fixation of pertrochanteric fracture is undoubtedly an additional trauma after the fracture itself. In elderly patients, it might have an important impact on the whole organism. In the literature we find various techniques to perform this type of surgery. Up to now, there are no parameters validated for quantification of the invasiveness of a surgical procedure; it is therefore still not demonstrated that any method is less invasive than any other. In an effort to find a way to quantify the invasiveness of a surgical procedure, inflammatory markers were collected in patients undergoing fixation of trochanteric fracture with gliding hip screw [dynamic hip screw (DHS)] using either a conventional (DHS conv) or minimally invasive (DHS MIO) technique. Method Two groups of patients were investigated prospectively; 36 of them were treated with conventional DHS technique and 32 with minimally invasive technique. Mean age was 84.7 ± 7.20 and 82.78 ± 7.71 years, respectively. Fracture type was classified according to the AO classification. Interleukin (IL)-6, IL-10, IL-8, and tumor necrosis factor (TNF)-α were measured 1 h before and 1 h after surgery. Student’s t test, chi-square test, and multivariate logistic regression were used for statistical analysis. Results Preoperative levels of interleukins showed no significant differences between the two groups. In contrast, the postoperative blood level of IL-6 in patients operated with DHS conv technique (78.41 ± 67.04 pg/ml) was on average higher than in patients operated by DHS MIO technique (39.02 ± 37.36 pg/ml), the mean difference being 39.39 pg/ml [95 % confidence interval (CI) 12.65–66.13 pg/ml; p = 0.0045]. Multivariate logistic regression (backward method with limit of significance 0.05) confirmed that patients operated by conventional technique were significantly more likely to have increased IL-6 after surgery than those operated by MIO technique. IL-8 was measured in only 36 patients (20 for DHS conv, 16 for DHS MIO). No significant differences were found between the two groups; however, there was a drastic decrease postoperatively (p < 0.0001) regardless of the type of surgery performed. IL-10 and TNF-α were tested in all subjects, but did not show significant differences between the two groups. Average length of incision was significantly different (4.61 cm, 95 % CI 3.50–5.71 cm; p < 0.001) between the two groups, being 11.65 ± 2.64 cm for DHS conv and 7.05 ± 1.77 cm for DHS MIO. Similarly, average units of red blood cells (RBCs) transfused [performed for hemoglobin (Hb) <9 g/dl and/or hematocrit (HCT) <27 %] was higher (2.22 ± 0.99) in the DHS conv group compared with the DHS MIO group (1.09 ± 1.20), with average difference of 1.13 (95 % CI 0.59–1.66; p < 0.001). Conclusions This attempt to quantify the invasiveness of internal fixation for trochanteric fracture comparing two techniques (DHS conv versus DHS MIO) based on inflammatory markers (IL-6) has given encouraging results. Measurement of systemic inflammatory response to local tissue damage caused by osteosynthesis using IL-6 as marker seems to confirm the lower invasiveness of MIO techniques. These results for trauma cases seem in line with those published for hip prosthesis. Ongoing further studies analyzing the effect of nailing will confirm or invalidate these preliminary results.

16 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Pietro RegazzoniPietro Regazzoni
Pietro Regazzoni
SLSimon M Lambert
Simon M Lambert
JJJesse B. Jupiter
Jesse B. Jupiter
NSNorbert Südkamp
Norbert Südkamp
WLWen-Chih Liu
Wen-Chih Liu
AFAlberto Angel Fernandez
Alberto Angel Fernandez
Good clinical practice guidelines are based on randomized controlled trials or clinical series; however, technical performance bias among surgical trials is under-assessed. The heterogeneity of technical performance within different treatment groups diminishes the level of evidence. Surgeon variability with different levels of experience—technical performance levels even after certification—influences surgical outcomes, especially in complex procedures. Technical performance quality correlates with the outcomes and costs and should be measured by image or video-photographic documentation of the surgeon’s view field during the procedures. Such consecutive, completely documented, unedited observational data—in the form of intra-operative images and a complete set of eventual radiological images—improve the surgical series’ homogeneity. Thereby, they might reflect reality and contribute towards making necessary changes for evidence-based surgery.

28 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Pietro RegazzoniPietro Regazzoni
Pietro Regazzoni
WLWen-Chih Liu
Wen-Chih Liu
JJJesse B. Jupiter
Jesse B. Jupiter
AFAlberto Angel Fernandez
Alberto Angel Fernandez
Intra-operative 3D X-rays have been confirmed to decrease revision rates and improve optimal screw placement in complex fractures of the distal radius. Compared with traditional surgical publications, another advantage of whole intraoperative clinical imaging can be presented in electronic databases, e.g., the ICUC working group, through a link without size limitation. The detail of complete intra-operative image dataset includes essential technical details which can be analyzed secondarily for costs and complications, considering the technical performance bias. Furthermore, the new format complies with reading/learning preferences of young surgeons and allows secondary work-up by artificial intelligence. Intra-operative 3D X-ray is a new approach for better surgical outcomes, economic benefit, and educational purposes.

27 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Pietro RegazzoniPietro Regazzoni
Pietro Regazzoni
JJJesse B. Jupiter
Jesse B. Jupiter
WLWen-Chih Liu
Wen-Chih Liu
AFAlberto Angel Fernandez
Alberto Angel Fernandez
Evidence-based medicine integrates results from randomized controlled trials (RCTs) and meta-analyses, combining the best external evidence with individual clinical expertise and patients’ preferences. However, RCTs of surgery differ from those of medicine in that surgical performance is often assumed to be consistent. Yet, evaluating whether each surgery is performed to the same standard is quite challenging. As a primary issue, the novelty of this review is to emphasize—with a focus on orthopedic trauma—the advantage of having complete intra-operative image documentation, allowing the direct evaluation of the quality of the intra-operative technical performance. The absence of complete intra-operative image documentation leads to the inhomogeneity of case series, yielding inconsistent results due to the impossibility of a secondary analysis. Thus, comparisons and the reproduction of studies are difficult. Access to complete intra-operative image data in surgical RCTs allows not only secondary analysis but also comparisons with similar cases. Such complete data can be included in electronic papers. Offering these data to peers—in an accessible link—when presenting papers facilitates the selection process and improves publications for readers. Additionally, having access to the full set of image data for all presented cases serves as a rich resource for learning. It enables the reader to sift through the information and pinpoint the details that are most relevant to their individual needs, allowing them to potentially incorporate this knowledge into daily practice. A broad use of the concept of complete intra-operative image documentation is pivotal for bridging the gap between clinical research findings and real-world applications. Enhancing the quality of surgical RCTs would facilitate the equalization of evidence acquisition in both internal medicine and surgery. Joint effort by surgeons, scientific societies, publishers, and healthcare authorities is needed to support the ideas, implement economic requirements, and overcome the mental obstacles to its realization.