Luciano Chiominto

Dr. Luciano Chiominto

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2024 in Engineering Failure Analysis
Verified
Journal Article
Closed access
Emanuela NataleEmanuela Natale
Emanuela Natale
Antonella GaspariAntonella Gaspari
Antonella Gaspari
LCLuciano Chiominto
Luciano Chiominto
GDGiulio D'EMilia
Giulio D'EMilia
ASAntonios Stamopoulos
Antonios Stamopoulos

31 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LCLuciano Chiominto
Luciano Chiominto
Giulio D'EmiliaGiulio D'Emilia
Giulio D'Emilia
Emanuela NataleEmanuela Natale
Emanuela Natale
In this work, a method for measuring tow angles in carbon fiber components, based on the use of a polarized camera, is analyzed from a metrological point of view. Carbon fibers alter the direction of the reflected light’s electrical field, so that in each point of the surface of a composite piece, the angle of polarization of reflected light matches the fiber orientation. A statistical analysis of the angle of linear polarization (AoLP) in each pixel of each examined area allows to evaluate the average winding angle. An evaluation of the measurement uncertainty of the method on a cylinder obtained by a filament winding process is carried out, and the result appears adequate for the study of the distribution of angles along the surface of the piece, in order to optimize the process.

27 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LCLuciano Chiominto
Luciano Chiominto
Giulio D'EmiliaGiulio D'Emilia
Giulio D'Emilia
Antonella GaspariAntonella Gaspari
Antonella Gaspari
Emanuela NataleEmanuela Natale
Emanuela Natale
A set of commercial triaxial micro-electromechanical systems (MEMS) accelerometers was calibrated using a custom-designed test bench featuring a rotating table. The calibration setup enabled simultaneous assessment of all accelerometer measurement components, generating precise reference accelerations within a frequency range of 0 to 8 Hz. A working model of the calibration setup and procedure was described to provide a complete uncertainty budget for both the reference and sensor accelerations. Through experimental uncertainty assessment of all the accelerometers, linearity and sensitivity were evaluated at different sensor levels. These parameters were determined by considering a single value for each accelerometer and detailing the analysis for each axis. Data processing revealed the achievable level of uncertainty and how it was influenced by the evaluation method employed for analyzing the calibration data.

30 May 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
LCLuciano Chiominto
Luciano Chiominto
Emanuela NataleEmanuela Natale
Emanuela Natale
Giulio D'EmiliaGiulio D'Emilia
Giulio D'Emilia
SGSante Grieco
Sante Grieco
Andrea PratoAndrea Prato
Andrea Prato
ASAlessandro Schiavi
Alessandro Schiavi
Sensors based on MEMS technology, in particular Inertial Measurement Units (IMUs), when installed on vehicles, provide a real-time full estimation of vehicles’ state vector (e.g., position, velocity, yaw angle, angular rate, acceleration), which is required for the planning and control of cars’ trajectories, as well as managing the in-car local navigation and positioning tasks. Moreover, data provided by the IMUs, integrated with the data of multiple inputs from other sensing systems (such as Lidar, cameras, and GPS) within the vehicle, and with the surrounding information exchanged in real time (vehicle to vehicle, vehicle to infrastructure, or vehicle to other entities), can be exploited to actualize the full implementation of “smart mobility” on a large scale. On the other hand, “smart mobility” (which is expected to improve road safety, reduce traffic congestion and environmental burden, and enhance the sustainability of mobility as a whole), to be safe and functional on a large scale, should be supported by highly accurate and trustworthy technologies based on precise and reliable sensors and systems. It is known that the accuracy and precision of data supplied by appropriately in-lab-calibrated IMUs (with respect to the primary or secondary standard in order to provide traceability to the International System of Units) allow guaranteeing high quality, reliable information managed by processing systems, since they are reproducible, repeatable, and traceable. In this work, the effective responsiveness and the related precision of digital IMUs, under sinusoidal linear and curvilinear motion conditions at 5 Hz, 10 Hz, and 20 Hz, are investigated on the basis of metrological approaches in laboratory standard conditions only. As a first step, in-lab calibrations allow one to reduce the variables of uncontrolled boundary conditions (e.g., occurring in vehicles in on-site tests) in order to identify the IMUs’ sensitivity in a stable and reproducible environment. For this purpose, a new calibration system, based on an oscillating rotating table was developed to reproduce the dynamic conditions of use in the field, and the results are compared with calibration data obtained on linear calibration benches.

10 June 2025 in ACTA IMEKO
Verified
Journal Article
Open access
PDF file
LCLuciano Chiominto
Luciano Chiominto
Giulio D'EmiliaGiulio D'Emilia
Giulio D'Emilia
Emanuela NataleEmanuela Natale
Emanuela Natale
In this work, the problem of determining the winding angle in a cylindrical carbon fiber piece, obtained through a filament winding process, is investigated. A polarization camera is used for the measurement, and the winding angle is determined by statistically analyzing the angle of linear polarization in each pixel of the region under study. The main influence parameters are considered, like non-planarity and superficial state of the piece, with the aim of reducing the measurement uncertainty. For this purpose, two different types of data processing approaches are tested and compared.

24 January 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
LCLuciano Chiominto
Luciano Chiominto
Giulio D'EmiliaGiulio D'Emilia
Giulio D'Emilia
Antonella GaspariAntonella Gaspari
Antonella Gaspari
Emanuela NataleEmanuela Natale
Emanuela Natale
A set of triaxial MEMS (Micro-Electro-Mechanical Systems) accelerometer, of commercial type, has been calibrated on a test bench, which is based on a rotating table. The bench has been designed for this specific purpose and it allows to calibrate contemporaneously all accelerometer measuring components, by realizing accurate reference accelerations in the frequency range 0 to 8 Hz. A working model of the calibration set-up and procedure is described to realize a complete and detailed uncertainty budget of the reference and of the sensor accelerations. Experimental uncertainty assessment of all the accelerometers has been carried out, allowing to obtain all the linearity and sensitivity data, accelerometer by accelerometer, axis by axis. Data processing has been carried out and interesting information is get about the level of uncertainty which is achievable, depending on the way the calibration data are evaluated, taking into account or not differences of sensitivity data for each other accelerometer and/or considering differences among measuring components of a single accelerometer.