Chair of The Department of Orthopaedic and Trauma Surgery, “Mater Domini” University Hospital, “Magna Græcia” University, V.le Europa (loc. Germaneto), 88100 Catanzaro, Italy
Prof. Dr. Giorgio Gasparini
Chair of The Department of Orthopaedic and Trauma Surgery, “Mater Domini” University Hospital, “Magna Græcia” University, V.le Europa (loc. Germaneto), 88100 Catanzaro, Italy
There is evidence supporting the use of extracorporeal shock wave therapy (ESWT) in calcific tendinopathy of the rotator cuff, but the best current evidence does not support its use in non-calcifying tendinopathy. We conducted a randomized placebo-controlled trial to investigate the efficacy and safety of low energy ESWT for non-calcifying tendinopathy of the rotator cuff.
Background: Minimally invasive distal metatarsal osteotomy (MIDMO) is a common technique used to correct the hallux valgus deformity, but controversy remains regarding the expected outcomes of this surgery. Methods: Seventy-two patients (85 feet) suffering from hallux valgus underwent MIDMO with a modified Bösch technique. Patients were prospectively evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) hallux score, and the AOFAS recovery rate was calculated. Before surgery and at follow-up, the hallux valgus (HVA), intermetatarsal (IMA), and distal metatarsal articular (DMAA) angles were measured, and the severity of disease was categorized according to the preoperative HVA. The tibial sesamoid position and articular congruence were evaluated. Postoperative complications were noted. Results: After an average follow-up of 73.3 ± 38.1 months, the total AOFAS score improved from 47.6 ± 13.3 to 87.3 ± 11.5 (P < .001). The HVA decreased from 34.7 ± 8.2 to 14.8 ± 7.8 degrees, the IMA from 14.7 ± 4 to 6.6 ± 3.6 degrees, and the DMAA from 20.9 ± 9.8 to 9 ± 6.6 degrees (P < .001 for all). Postoperative improvement in AOFAS was inversely related to the preoperative severity of disease (P < .001, β = –.378). Sixteen (18.8%) deformity recurrences were noted, 9 of which were observed in patients with preoperative HVA more than 40 degrees. Worse preoperative congruence of the metatarsophalangeal joint and tibial sesamoid position correlated with a higher rate of recurrence of the disease after surgery (P = .001, β = –.353 and P < .001, β = .427, respectively). Conclusions: Satisfactory clinical and radiological results can be expected after MIDMO, but caution should be exercised when using this technique because of the likelihood of possible complications (29.4% overall complication rate). Predictors of surgical outcomes can be used to select the best candidates for this surgery. Level of Evidence: Level IV, case series.
13 May 2015 in Clinical Orthopaedics and Related Research
Multiple studies have reported favorable short-term outcomes using tantalum cones to reconstruct massive bone defects during revision TKA. However, longer-term followup is needed to determine the durability of these reconstructions. We wished to determine the mid-term (1) reoperation rates for septic and aseptic causes, (2) radiologic findings of osseointegration, and (3) clinical outcomes based on the Knee Society score in patients who underwent revision knee arthroplasty with tantalum cones for severe bone loss. We retrospectively evaluated records of 18 patients (18 knees) who underwent revision knee arthroplasty with use of tantalum cones between 2005 and 2008; the primary indications for use of this approach were to reconstruct massive bone defects classified as Anderson Orthopaedic Research Institute Types 2B and 3. During this period, all defects of this type were treated with this approach and no cones were used for more-minor defects. A total of 26 cones (13 tibial and 13 femoral) were implanted. There were 12 female and six male patients with a mean age of 73 years (range, 55–84 years) at the time of revision. The indication for the revision included aseptic loosening (five patients) and second-stage reimplantation for deep infection (13 patients). Patients were followed for a mean of 6 years (range, 5–8 years). No patient was lost to followup. Clinical and radiographic outcomes were assessed with the Knee Society clinical rating system and radiographic evaluation system. There have been two reoperations for recurrent infection; at surgery, the two cones showed osseointegration. No evidence of loosening or migration of any implant was noted on the most recent radiographs. Knee Society knee scores improved from a mean of 31 points before surgery to 77 points at latest followup (p < 0.001), and function scores improved from a mean of 22 points to 65 points (p < 0.001). Tantalum cones for reconstruction of massive bone defects in revision knee arthroplasty provided secure fixation with excellent results at average followup of 6 years, although this series included relatively few patients. These devices are a viable option for surgeons to use in situations with severe bone loss. Further studies with longer followups are needed to confirm the durability of these reconstructions. Level IV, therapeutic study.
1 April 2016 in Journal of Shoulder and Elbow Surgery