Vincenzo De Santis

Prof. Dr. Vincenzo De Santis

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2003 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
MGM. Galli
M. Galli
VSVincenzo De Santis
Vincenzo De Santis
LTL. Tafuro
L. Tafuro

13 May 2015 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
IMIvan De Martino
Ivan De Martino
VSVincenzo De Santis
Vincenzo De Santis
PSPeter K. Sculco
Peter K. Sculco
RDRocco D’apolito
Rocco D’apolito
JAJoseph B. Assini
Joseph B. Assini
Giorgio GaspariniGiorgio Gasparini
Giorgio Gasparini
Multiple studies have reported favorable short-term outcomes using tantalum cones to reconstruct massive bone defects during revision TKA. However, longer-term followup is needed to determine the durability of these reconstructions. We wished to determine the mid-term (1) reoperation rates for septic and aseptic causes, (2) radiologic findings of osseointegration, and (3) clinical outcomes based on the Knee Society score in patients who underwent revision knee arthroplasty with tantalum cones for severe bone loss. We retrospectively evaluated records of 18 patients (18 knees) who underwent revision knee arthroplasty with use of tantalum cones between 2005 and 2008; the primary indications for use of this approach were to reconstruct massive bone defects classified as Anderson Orthopaedic Research Institute Types 2B and 3. During this period, all defects of this type were treated with this approach and no cones were used for more-minor defects. A total of 26 cones (13 tibial and 13 femoral) were implanted. There were 12 female and six male patients with a mean age of 73 years (range, 55–84 years) at the time of revision. The indication for the revision included aseptic loosening (five patients) and second-stage reimplantation for deep infection (13 patients). Patients were followed for a mean of 6 years (range, 5–8 years). No patient was lost to followup. Clinical and radiographic outcomes were assessed with the Knee Society clinical rating system and radiographic evaluation system. There have been two reoperations for recurrent infection; at surgery, the two cones showed osseointegration. No evidence of loosening or migration of any implant was noted on the most recent radiographs. Knee Society knee scores improved from a mean of 31 points before surgery to 77 points at latest followup (p < 0.001), and function scores improved from a mean of 22 points to 65 points (p < 0.001). Tantalum cones for reconstruction of massive bone defects in revision knee arthroplasty provided secure fixation with excellent results at average followup of 6 years, although this series included relatively few patients. These devices are a viable option for surgeons to use in situations with severe bone loss. Further studies with longer followups are needed to confirm the durability of these reconstructions. Level IV, therapeutic study.

1 April 2015 in Orthopedics
Verified
Journal Article
Closed access
PDF file
FFFerdinando Ferrara
Ferdinando Ferrara
ACAntonio Cipriani
Antonio Cipriani
NMnicola magarelli
nicola magarelli
SRSanti Rapisarda
Santi Rapisarda
VSVincenzo De Santis
Vincenzo De Santis
LBLorenzo Bonomo
Lorenzo Bonomo
The number of total knee arthroplasty (TKA) procedures continuously increases, with good to excellent results. In the last few years, new surgical techniques have been developed to improve prosthesis positioning. In this context, patient-specific instrumentation is included. The goal of this study was to compare the perioperative parameters and the spatial positioning of prosthetic components in TKA procedures performed with patient-specific instrumentation vs traditional TKA. In this prospective comparative randomized study, 15 patients underwent TKA with 3-dimensional magnetic resonance imaging (MRI) preoperative planning (patient-specific instrumentation group) and 15 patients underwent traditional TKA (non–patient-specific instrumentation group). All patients underwent postoperative computed tomography (CT) examination. In the patient-specific instrumentation group, preoperative data planning regarding femoral and tibial bone resection was correlated with intraoperative measurements. Surgical time, length of hospitalization, and intraoperative and postoperative bleeding were compared between the 2 groups. Positioning of implants on postoperative CT was assessed for both groups. Data planned with 3-dimensional MRI regarding the depth of bone cuts showed good to excellent correlation with intraoperative measurements. The patient-specific instrumentation group showed better perioperative outcomes and good correlation between the spatial positioning of prosthetic components planned preoperatively and that seen on postoperative CT. Less variability was found in the patient-specific instrumentation group than in the non–patient-specific instrumentation group in spatial orientation of prosthetic components. Preoperative planning with 3-dimensional MRI in TKA has a better perioperative outcome compared with the traditional method. Use of patient-specific instrumentation can also improve the spatial positioning of both prosthetic components. [ Orthopedics. 2015; 38(4):e271–e280.]

10 May 2006 in Journal of Trace Elements in Medicine and Biology
Verified
Journal Article
Closed access
Ivo IavicoliIvo Iavicoli
Ivo Iavicoli
GFGianluca Falcone
Gianluca Falcone
MAMaria Alessandrelli
Maria Alessandrelli
RCRaffaella Cresti
Raffaella Cresti
VSVincenzo De Santis
Vincenzo De Santis
GCGiovanni Carelli
Giovanni Carelli

16 December 2015 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
PDF file
IMIvan De Martino
Ivan De Martino
VSVincenzo De Santis
Vincenzo De Santis
PSPeter K. Sculco
Peter K. Sculco
RDRocco D’apolito
Rocco D’apolito
LPLazaros A. Poultsides
Lazaros A. Poultsides
Giorgio GaspariniGiorgio Gasparini
Giorgio Gasparini

1 January 2017 in The Bone & Joint Journal
Verified
Journal Article
Closed access
PDF file
IMIvan De Martino
Ivan De Martino
VSVincenzo De Santis
Vincenzo De Santis
RAR. D’ Apolito
R. D’ Apolito
PSP. K. Sculco
P. K. Sculco
MCM. B. Cross
M. B. Cross
GGG. Gasparini
G. Gasparini
Aims We report on the outcome of the Synergy cementless femoral stem with a minimum follow-up of 15 years (15 to 17). Patients and Methods A retrospective review was undertaken of a consecutive series of 112 routine primary cementless total hip arthroplasties (THAs) in 102 patients (112 hips). There were 60 female and 42 male patients with a mean age of 61 years (18 to 82) at the time of surgery. A total of 78 hips in the 69 patients remain in situ ; nine hips in eight patients died before 15 years, and 16 hips in 16 patients were revised. Clinical outcome scores and radiographs were available for 94 hips in 85 patients. Results In all, four stems were revised. One stem was revised for aseptic loosening; two stems because of deep infection; and one because of periprosthetic femoral fracture. There was a significant improvement in all components of the Western Ontario and McMaster Universities Osteoarthritis Index score at the final follow-up (total: p < 0.001, pain: p < 0.001, stiffness: p < 0.001, function: p < 0.001). The mean Harris Hip Scores improved from 47 points (27 to 59) pre-operatively to 89 points (65 to 100) at the latest follow-up (p < 0.001). Kaplan-Meier survivorship, with stem revision for aseptic loosening as the endpoint, was 98.9% at 15 years (95% confidence interval (CI) 96.9 to 100, number at risk at 15 years: 90) and with stem revision for any reason was 95.7% (95% CI 91.7 to 99.8, number at risk at 15 years: 90). Conclusion The Synergy cementless femoral stem demonstrates excellent survivorship and functional outcomes at 15 years. Cite this article: Bone Joint J 2017;99-B:29–36.