This work introduced additively manufactured non-assembly, miniaturized pin-joints for pantographic metamaterials as perfect pivots. The titanium alloy Ti6Al4V was utilized with laser powder bed fusion technology. The pin-joints were produced using optimized process parameters required for manufacturing miniaturized joints, and they were printed at a particular angle to the build platform. Additionally, this process optimization will eliminate the requirement to geometrically compensate the computer-aided design model, allowing for even further miniaturization. In this work, pin-joint lattice structures known as pantographic metamaterials were taken into consideration. The mechanical behavior of the metamaterial was characterized by bias extension tests and cyclic fatigue experiments, showing superior levels of performance (no sign of fatigue for 100 cycles of an elongation of approximately 20%) in comparison to classic pantographic metamaterials made with rigid pivots. The individual pin-joints, with a pin diameter of 350 to 670 µm, were analyzed using computed tomography scans, indicating that the mechanism of the rotational joint functions well even though the clearance of 115 to 132 µm between the moving parts is comparable to the nominal spatial resolution of the printing process. Our findings emphasize new possibilities to develop novel mechanical metamaterials with actual moving joints on a small scale. The results will also support stiffness-optimized metamaterials with variable-resistance torque for non-assembly pin-joints in the future.
This work analyses damage formation within the bulk of basalt fiber-reinforced polymers (BFRP) by means of open-source Digital Volume Correlation (DVC). Volumetric image data were obtained from conventional in-situ X-Ray computed micro-tomography (µCT) of samples loaded in tension. The open-source image registration toolkit Elastix was employed to obtain full 3D displacement fields from the image data. We assessed the accuracy of the DVC results using the method of manufactured solution and showed that the approach followed here can detect deformation with a magnitude in the order of a fiber diameter which in the present case is 17 µm. The beneficial influence of regularization on DVC results is presented on the manufactured solution as well as on real in-situ tensile testing CT data of a BFRP sample. Results of the correlation showed that conventional µCT equipment in combination with DVC can be used to detect defects which could previously only be visualized using synchrotron facilities or destructive methods.
The utilisation of high-resolution in situ computed tomography (CT) in the (sub-)μm range is typically only viable in synchrotron facilities, as the deployment of a conventional loading stage in laboratory CTs with a cone beam source does not facilitate a corresponding geometric magnification. This publication presents a CT system with a novel in situ concept that allows spatial resolutions down to 0.5 μm, enabling the analysis of weakly absorbing materials capable of applying loads of up to 5 kN in both the compression and tension directions to the sample during the measurement. The necessity for a highly precise mechanical design to ensure successful measurements at magnifications approaching the theoretical limit makes the system’s development particularly demanding. The components employed are presented, along with the requisite considerations and methodologies. It can be demonstrated that the intended specifications with regard to precision and quality are met. The experimental results of a fibre-reinforced polymer demonstrate the system’s ability to detect matrix damage features below a single fibre diameter, thereby highlighting its potential for applications in materials science where traditional laboratory CTs are insufficient and synchrotron access is limited.