Christiana Pessoa

Dr. Christiana Pessoa


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
DLDhesmon Lima
Dhesmon Lima
JIJuliana Inaba
Juliana Inaba
LLLuma Clarindo Lopes
Luma Clarindo Lopes
GCGiselle Nathaly Calaça
Giselle Nathaly Calaça
PWPatrícia Los Weinert
Patrícia Los Weinert
CPChristiana Pessoa
Christiana Pessoa

1 February 2021 in Talanta
Verified
Journal Article
Closed access
LLLuma Clarindo Lopes
Luma Clarindo Lopes
DLDhesmon Lima
Dhesmon Lima
AHAna Carolina Mendes Hacke
Ana Carolina Mendes Hacke
BSBianca Siqueira Schveigert
Bianca Siqueira Schveigert
GCGiselle Nathaly Calaça
Giselle Nathaly Calaça
CPChristiana Pessoa
Christiana Pessoa

25 January 2011 in Sensors
Verified
Journal Article
Open access
PDF file
TSTatiane Skeika
Tatiane Skeika
CZCristiane R. Zuconelli
Cristiane R. Zuconelli
SFSergio T. Fujiwara
Sergio T. Fujiwara
CPChristiana Pessoa
Christiana Pessoa
The present paper describes the characterization of a carbon ceramic electrode modified with ferrocenecarboxylic acid (designated as CCE/Fc) by electrochemical techniques and its detection ability for dopamine. From cyclic voltammetric experiments, it was observed that the CCE/Fc presented a redox pair at Epa = 405 mV and Epc = 335 mV (DE = 70 mV), related to the ferrocene/ferrocenium process. Studies showed a considerably increase in the redox currents at the same oxidation potential of ferrocene (Epa = 414 mV vs. Ag/AgCl) in the presence of dopamine (DA), differently from those observed when using only the unmodified CCE, in which the anodic peak increase was considerably lower. From SWV experiments, it was observed that the AA (ascorbic acid) oxidation at CCE/Fc occurred in a different potential than the DA oxidation (with a peak separation of approximately 200 mV). Moreover, CCE/Fc did not respond to different AA concentrations, indicating that it is possible to determine DA without the AA interference with this electrode.

9 March 2018 in Journal of Applied Electrochemistry
Verified
Journal Article
Closed access
PDF file
ASAndressa Hornes Schebeliski
Andressa Hornes Schebeliski
DLDhesmon Lima
Dhesmon Lima
Luis Fernando MarchesiLuis Fernando Marchesi
Luis Fernando Marchesi
CCCarolina Maria Fioramonti Calixto
Carolina Maria Fioramonti Calixto
CPChristiana Pessoa
Christiana Pessoa

1 September 2013 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
CJCliciane Guadalupe de Jesus
Cliciane Guadalupe de Jesus
DLDhesmon Lima
Dhesmon Lima
VSVagner dos Santos
Vagner dos Santos
Karen WohnrathKaren Wohnrath
Karen Wohnrath
CPChristiana Pessoa
Christiana Pessoa

27 July 2014 in Journal of Applied Electrochemistry
Verified
Journal Article
Closed access
PDF file
CSCleverson Siqueira Santos
Cleverson Siqueira Santos
RFRodolfo Thiago Ferreira
Rodolfo Thiago Ferreira
CCCarolina Maria Fioramonti Calixto
Carolina Maria Fioramonti Calixto
JRJosé Luiz Rufino
José Luiz Rufino
JGJarem Raul Garcia
Jarem Raul Garcia
CPChristiana Pessoa
Christiana Pessoa