Cleverson Siqueira Santos

Cleverson Siqueira Santos

Auto-generated profile, based on publicly available information

Cleverson Siqueira Santos

Universidade Estadual de Ponta Grossa – UEPG

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2015 in Journal of Applied Electrochemistry
Verified
Journal Article
Closed access
PDF file
CSCleverson Siqueira Santos
Cleverson Siqueira Santos
RMRosana Mossanha
Rosana Mossanha
CPChristiana Pessoa
Christiana Pessoa

27 July 2014 in Journal of Applied Electrochemistry
Verified
Journal Article
Closed access
PDF file
CSCleverson Siqueira Santos
Cleverson Siqueira Santos
RFRodolfo Thiago Ferreira
Rodolfo Thiago Ferreira
CCCarolina Maria Fioramonti Calixto
Carolina Maria Fioramonti Calixto
JRJosé Luiz Rufino
José Luiz Rufino
JGJarem Raul Garcia
Jarem Raul Garcia
CPChristiana Pessoa
Christiana Pessoa

1 April 2015 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
RMRosana Mossanha
Rosana Mossanha
MRMaria Karolina Ramos
Maria Karolina Ramos
CSCleverson Siqueira Santos
Cleverson Siqueira Santos
CPChristiana Andrade Pessoa
Christiana Andrade Pessoa
A horseradish peroxidase (HRP) biosensor was constructed using binary self-assembled monolayers (SAM) of 11-mercaptoundecanoic acid (MUA) and thiolactic acid (TLA) on gold surface. The advantages of using mixed SAM for the enzyme immobilization is that the long carbon chain molecules act as a support for the enzyme while the short chain molecules favor the electron transfer process. In order to obtain this modified surface, the gold electrode was incubated in a solution containing different proportions of MUA and TLA and the best concentration ratio of these molecules was 0.5 and 1.0 mmol L−1, respectively. The preparation steps and the biosensor response were monitored by electrochemical techniques. The biosensor proposed was applied to determine hydroquinone in a 0.10 mol L−1 phosphate buffer solution containing H2O2 0.3 mmol L−1. The Au-SAMmix-HRP electrode, in the presence of hydrogen peroxide, catalyzes the oxidation of hydroquinone to the corresponding quinone, which is electrochemically reduced back to hydroquinone at −0.08 V vs Ag/AgCl. The analytical curve was linear for hydroquinone concentrations from 5.0 to 30 μmol L−1 and the detection limit was 1.26 μmol L−1. The lifetime of this biosensor was 15 days. The modified electrode displayed good reproducibility, sensitivity and stability for the determination of hydroquinone.

27 January 2016 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
CSCleverson Siqueira Santos
Cleverson Siqueira Santos
RMRosana Mossanha
Rosana Mossanha
Karen WohnrathKaren Wohnrath
Karen Wohnrath
JIJuliana Inaba
Juliana Inaba
CPChristiana Pessoa
Christiana Pessoa
This paper describes the development of a label-free electrochemical immunosensor for the qualitative detection of American trypanosomiasis in serum samples. The immunosensor was constructed using self assembled monolayer technique with gold substrate modified with monolayer of 3-mercaptopropionic acid. The T. cruzi antigens were immobilized after activation carboxylic groups in monolayer with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and N-hydroxysuccinimide. The parameters that can interfere the impedimetric response of the immunosensor response such as, concentration and incubation time in the solution of T. cruzi antigens, concentration of bovine serum albumin and incubation time in the solution of T. cruzi antibodies were optimized in the presence of the probe molecule hexacyanoferrate(II)/(III), using cyclic voltammetry and electrochemical impedance spectroscopy. The interaction between antigen–antibody was monitored using electrochemical impedance spectroscopy and the results were expressed in terms of the increase of the charge transfer resistance across the interface. The immunosensor showed selective and sensitive in the qualitative detection of T. cruzi antibodies in serum samples infected with toxoplasma antibodies. Therefore, the proposed methodology is a promising alternative for the development of a immunosensor for serological qualitative diagnosis of Chagas disease.

1 January 2015 in Revista Virtual de Química
Verified
Journal Article
Closed access
CSCleverson S. Santos
Cleverson S. Santos
RMRosana Mossanha
Rosana Mossanha
Luis Fernando MarchesiLuis Fernando Marchesi
Luis Fernando Marchesi
CPChristiana A. Pessôa
Christiana A. Pessôa