James E. West

Dr. James E. West


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2015 in Sensors
Verified
Journal Article
Open access
PDF file
KSKumjae Shin
Kumjae Shin
JJJunsik Jeon
Junsik Jeon
JWJames E. West
James E. West
WMWonkyu Moon
Wonkyu Moon
Capacitive-type transduction is now widely used in MEMS microphones. However, its sensitivity decreases with reducing size, due to decreasing air gap capacitance. In the present study, we proposed and developed the Electret Gate of Field Effect Transistor (ElGoFET) transduction based on an electret and FET (field-effect-transistor) as a novel mechanism of MEMS microphone transduction. The ElGoFET transduction has the advantage that the sensitivity is dependent on the ratio of capacitance components in the transduction structure. Hence, ElGoFET transduction has high sensitivity even with a smaller air gap capacitance, due to a miniaturization of the transducer. A FET with a floating-gate electrode embedded on a membrane was designed and fabricated and an electret was fabricated by ion implantation with Ga+ ions. During the assembly process between the FET and the electret, the operating point of the FET was characterized using the static response of the FET induced by the electric field due to the trapped positive charge at the electret. Additionally, we evaluated the microphone performance of the ElGoFET by measuring the acoustic response in air using a semi-anechoic room. The results confirmed that the proposed transduction mechanism has potential for microphone applications.

20 July 2023 in ACS Applied Bio Materials
Verified
Journal Article
Closed access
VRValerie Rennoll
Valerie Rennoll
IMIan McLane
Ian McLane
AEAdebayo Eisape
Adebayo Eisape
DGDrew Grant
Drew Grant
HHHelena Hahn
Helena Hahn
JWJames E. West
James E. West

6 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DGDrew Edward Grant
Drew Edward Grant
IMIan McLane
Ian McLane
VRValerie Rennoll
Valerie Rennoll
JWJames E. West
James E. West
Coronavirus disease 2019 (COVID-19) has led to countless deaths and widespread global disruptions. Acoustic-based artificial intelligence (AI) tools could provide a simple, scalable, and prompt method to screen for COVID-19 using easily acquirable physiological sounds. These systems have been demonstrated previously and have shown promise but lack robust analysis of their deployment in real-world settings when faced with diverse recording equipment, noise environments, and test subjects. The primary aim of this work is to begin to understand the impacts of these real-world deployment challenges on the system performance. Using Mel-Frequency Cepstral Coefficients (MFCC) and RelAtive SpecTrAl-Perceptual Linear Prediction (RASTA-PLP) features extracted from cough, speech, and breathing sounds in a crowdsourced dataset, we present a baseline classification system that obtains an average receiver operating characteristic area under the curve (AUC-ROC) of 0.77 when discriminating between COVID-19 and non-COVID subjects. The classifier performance is then evaluated on four additional datasets, resulting in performance variations between 0.64 and 0.87 AUC-ROC, depending on the sound type. By analyzing subsets of the available recordings, it is noted that the system performance degrades with certain recording devices, noise contamination, and with symptom status. Furthermore, performance degrades when a uniform classification threshold from the training data is subsequently used across all datasets. However, the system performance is robust to confounding factors, such as gender, age group, and the presence of other respiratory conditions. Finally, when analyzing multiple speech recordings from the same subjects, the system achieves promising performance with an AUC-ROC of 0.78, though the classification does appear to be impacted by natural speech variations. Overall, the proposed system, and by extension other acoustic-based diagnostic aids in the literature, could provide comparable accuracy to rapid antigen testing but significant deployment challenges need to be understood and addressed prior to clinical use.

1 May 2008 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
JWJames E. West
James E. West
IBIlene Busch-Vishniac
Ilene Busch-Vishniac
JKJoseph King
Joseph King
NLNatalia Levit
Natalia Levit
In our previous study reported in INTER‐NOISE 2006 we found that operating rooms are among the most problematic areas in the healthcare industry. The maximum peak levels measured during various surgical procedures are extremely high ‐ 100‐120 dB, which can potentially lead to the hearing damage and interfere with the speech communication during surgery. Neurosurgery and orthopedic operating rooms are found to be among the noisiest overall. However, introduction of the acoustical materials to the operating room is very difficult due to the strict infectious control requirements. We report here a case study on using sound absorptive panels protected by DuPont Tyvek®, a unique flash spun plexifilamentary film‐fibril sheet, combining excellent barrier properties with distinctive porous structure to make it acoustically transparent in the voice frequency range.

13 May 2014 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
KRKailiang Ren
Kailiang Ren
JWJames E. West
James E. West
SYS. Michael Yu
S. Michael Yu
Velocity and pressure microphones composed of piezoelectric poly(γ-benzyl-α,L-glutamate) (PBLG) nanofibers were produced by adhering a single layer of PBLG film to a Mylar diaphragm. The device exhibited a sensitivity of −60 dBV/Pa in air, and both pressure and velocity response showed a broad frequency response that was primarily controlled by the stiffness of the supporting diaphragm. The pressure microphone response was ±3 dB between 200 Hz and 4 kHz when measured in a semi-anechoic chamber. Thermal stability, easy fabrication, and simple design make this single element transducer ideal for various applications including those for underwater and high temperature use.

14 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AEAdebayo Eisape
Adebayo Eisape
VRValerie Rennoll
Valerie Rennoll
TVTessa Van Volkenburg
Tessa Van Volkenburg
ZXZhiyong Xia
Zhiyong Xia
JWJames E. West
James E. West
Sung Hoon KangSung Hoon Kang
Sung Hoon Kang
Carbon–polymer composite-based pressure sensors have many attractive features, including low cost, easy integration, and facile fabrication. Previous studies on carbon–polymer composite sensors focused on very high sensitivities for low pressure ranges (10 s of kPa), which saturate quickly at higher pressures and thus are ill-suited to measure the high pressure ranges found in various applications, including those in underwater (>1 atm, 101 kPa) and industrial environments. Current sensors designed for high pressure environments are often difficult to fabricate, expensive, and, similarly to their low-pressure counterparts, have a narrow sensing range. To address these issues, this work reports the design, synthesis, characterization, and analysis of high-pressure TPU-MWCNT based composite sensors, which detect pressures from 0.5 MPa (4.9 atm) to over 10 MPa (98.7 atm). In this study, the typical approach to improve sensitivity by increasing conductive additive concentration was found to decrease sensor performance at elevated pressures. It is shown that a better approach to elevated pressure sensitivity is to increase sensor response range by decreasing the MWCNT weight percentage, which improves sensing range and resolution. Such sensors can be useful for measuring high pressures in many industrial (e.g., manipulator feedback), automotive (e.g., damping elements, bushings), and underwater (e.g., depth sensors) applications.