Ian McLane

Mr. Ian McLane

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
IMIan McLane
Ian McLane
DEDimitra Emmanouilidou
Dimitra Emmanouilidou
JWJames E West
James E West
MEMounya Elhilali
Mounya Elhilali
Chest auscultation is a widely used clinical tool for respiratory disease detection. The stethoscope has undergone a number of transformative enhancements since its invention, including the introduction of electronic systems in the last two decades. Nevertheless, stethoscopes remain riddled with a number of issues that limit their signal quality and diagnostic capability, rendering both traditional and electronic stethoscopes unusable in noisy or non-traditional environments (e.g., emergency rooms, rural clinics, ambulatory vehicles). This work outlines the design and validation of an advanced electronic stethoscope that dramatically reduces external noise contamination through hardware redesign and real-time, dynamic signal processing. The proposed system takes advantage of an acoustic sensor array, an external facing microphone, and on-board processing to perform adaptive noise suppression. The proposed system is objectively compared to six commercially-available acoustic and electronic devices in varying levels of simulated noisy clinical settings and quantified using two metrics that reflect perceptual audibility and statistical similarity, normalized covariance measure (NCM) and magnitude squared coherence (MSC). The analyses highlight the major limitations of current stethoscopes and the significant improvements the proposed system makes in challenging settings by minimizing both distortion of lung sounds and contamination by ambient noise.

11 May 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
VRValerie Rennoll
Valerie Rennoll
IMIan McLane
Ian McLane
DEDimitra Emmanouilidou
Dimitra Emmanouilidou
JWJames West
James West
MEMounya Elhilali
Mounya Elhilali
Electronic stethoscopes offer several advantages over conventional acoustic stethoscopes, including noise reduction, increased amplification, and ability to store and transmit sounds. However, the acoustical characteristics of electronic and acoustic stethoscopes can differ significantly, introducing a barrier for clinicians to transition to electronic stethoscopes. This work proposes a method to process lung sounds recorded by an electronic stethoscope, such that the sounds are perceived to have been captured by an acoustic stethoscope. The proposed method calculates an electronic-to-acoustic stethoscope filter by measuring the difference between the average frequency responses of an acoustic and an electronic stethoscope to multiple lung sounds. To validate the method, a change detection experiment was conducted with 51 medical professionals to compare filtered electronic, unfiltered electronic, and acoustic stethoscope lung sounds. Participants were asked to detect when transitions occurred in sounds comprising several sections of the three types of recordings. Transitions between the filtered electronic and acoustic stethoscope sections were detected, on average, by chance (sensitivity index equal to zero) and also detected significantly less than transitions between the unfiltered electronic and acoustic stethoscope sections (p <; 0.01), demonstrating the effectiveness of the method to filter electronic stethoscopes to mimic an acoustic stethoscope. This processing could incentivize clinicians to adopt electronic stethoscopes by providing a means to shift between the sound characteristics of acoustic and electronic stethoscopes in a single device, allowing for a faster transition to new technology and greater appreciation for the electronic sound quality.

7 October 2022 in Artificial Intelligence in Medicine
Verified
Journal Article
Closed access
Farhat Binte AzamFarhat Binte Azam
Farhat Binte Azam
IAIstiaq Ansari
Istiaq Ansari
SNShoyad Ibn Sabur Khan Nuhash
Shoyad Ibn Sabur Khan Nuhash
IMIan McLane
Ian McLane
THTaufiq Hasan
Taufiq Hasan

27 October 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
IMIan McLane
Ian McLane
ELEline Lauwers
Eline Lauwers
TSToon Stas
Toon Stas
IBIlene Busch-Vishniac
Ilene Busch-Vishniac
KIKris Ides
Kris Ides
JSJan Steckel
Jan Steckel
Digital auscultation is a well-known method for assessing lung sounds, but remains a subjective process in typical practice, relying on the human interpretation. Several methods have been presented for detecting or analyzing crackles but are limited in their real-world application because few have been integrated into comprehensive systems or validated on non-ideal data. This work details a complete signal analysis methodology for analyzing crackles in challenging recordings. The procedure comprises five sequential processing blocks: (1) motion artifact detection, (2) deep learning denoising network, (3) respiratory cycle segmentation, (4) separation of discontinuous adventitious sounds from vesicular sounds, and (5) crackle peak detection. This system uses a collection of new methods and robustness-focused improvements on previous methods to analyze respiratory cycles and crackles therein. To validate the accuracy, the system is tested on a database of 1000 simulated lung sounds with varying levels of motion artifacts, ambient noise, cycle lengths and crackle intensities, in which ground truths are exactly known. The system performs with average F-score of 91.07% for detecting motion artifacts and 94.43% for respiratory cycle extraction, and an overall F-score of 94.08% for detecting the locations of individual crackles. The process also successfully detects healthy recordings. Preliminary validation is also presented on a small set of 20 patient recordings, for which the system performs comparably. These methods provide quantifiable analysis of respiratory sounds to enable clinicians to distinguish between types of crackles, their timing within the respiratory cycle, and the level of occurrence. Crackles are one of the most common abnormal lung sounds, presenting in multiple cardiorespiratory diseases. These features will contribute to a better understanding of disease severity and progression in an objective, simple and non-invasive way.

6 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DGDrew Edward Grant
Drew Edward Grant
IMIan McLane
Ian McLane
VRValerie Rennoll
Valerie Rennoll
JWJames E. West
James E. West
Coronavirus disease 2019 (COVID-19) has led to countless deaths and widespread global disruptions. Acoustic-based artificial intelligence (AI) tools could provide a simple, scalable, and prompt method to screen for COVID-19 using easily acquirable physiological sounds. These systems have been demonstrated previously and have shown promise but lack robust analysis of their deployment in real-world settings when faced with diverse recording equipment, noise environments, and test subjects. The primary aim of this work is to begin to understand the impacts of these real-world deployment challenges on the system performance. Using Mel-Frequency Cepstral Coefficients (MFCC) and RelAtive SpecTrAl-Perceptual Linear Prediction (RASTA-PLP) features extracted from cough, speech, and breathing sounds in a crowdsourced dataset, we present a baseline classification system that obtains an average receiver operating characteristic area under the curve (AUC-ROC) of 0.77 when discriminating between COVID-19 and non-COVID subjects. The classifier performance is then evaluated on four additional datasets, resulting in performance variations between 0.64 and 0.87 AUC-ROC, depending on the sound type. By analyzing subsets of the available recordings, it is noted that the system performance degrades with certain recording devices, noise contamination, and with symptom status. Furthermore, performance degrades when a uniform classification threshold from the training data is subsequently used across all datasets. However, the system performance is robust to confounding factors, such as gender, age group, and the presence of other respiratory conditions. Finally, when analyzing multiple speech recordings from the same subjects, the system achieves promising performance with an AUC-ROC of 0.78, though the classification does appear to be impacted by natural speech variations. Overall, the proposed system, and by extension other acoustic-based diagnostic aids in the literature, could provide comparable accuracy to rapid antigen testing but significant deployment challenges need to be understood and addressed prior to clinical use.

19 September 2025 in Journal of Global Health
Verified
Journal Article
Open access
NHNadia E Hoekstra
Nadia E Hoekstra
MCMaganizo B Chagomerana
Maganizo B Chagomerana
ZSZachary H Smith
Zachary H Smith
AKAnnapurna Kala
Annapurna Kala
IMIan McLane
Ian McLane
EMEric D McCollum
Eric D McCollum
Pneumonia remains the leading infectious cause of mortality in children under five worldwide [1,2]. The World Health Organization (WHO) Integrated Management of Childhood Illnesses (IMCI) guidelines provide the current standard for managing paediatric pneumonia in low-income and middle-income countries (LMICs) [3]. Developed in the 1980s, the IMCI algorithm enables non-physician health care workers (HCWs) to […]