Wentao Wu

Dr. Wentao Wu

Department of Civil and Natural Resources Engineering, University of Canterbury, Christchurch, New Zealand
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Applied Energy
Verified
Journal Article
Closed access
Wentao WuWentao Wu
Wentao Wu
CBClaudio Beretta
Claudio Beretta
PCPaul Cronje
Paul Cronje
SHStefanie Hellweg
Stefanie Hellweg
TDThijs Defraeye
Thijs Defraeye

2 February 2025 in Applied Thermal Engineering
Verified
Journal Article
Closed access
KXKe Xiang
Ke Xiang
ZTZhiyong Tian
Zhiyong Tian
CZChaohui Zhou
Chaohui Zhou
YLYongqiang Luo
Yongqiang Luo
Wentao WuWentao Wu
Wentao Wu
MDMahdi Deymi-Dashtebayaz
Mahdi Deymi-Dashtebayaz

22 January 2022 in Applied Thermal Engineering
Verified
Journal Article
Closed access
JBJingru Z. Benner
Jingru Z. Benner
RSRebecca C. Shannon
Rebecca C. Shannon
Wentao WuWentao Wu
Wentao Wu
LSLu Shen
Lu Shen
AMAusten P. Metsack
Austen P. Metsack
JZJingzhou Zhao
Jingzhou Zhao

11 September 2024 in Eng
Verified
Journal Article
Open access
PDF file
Daniel James BishopDaniel James Bishop
Daniel James Bishop
MMMahdi Mohkam
Mahdi Mohkam
BWBaxter Williams
Baxter Williams
Wentao WuWentao Wu
Wentao Wu
LBLarry Bellamy
Larry Bellamy
Level of detail (LoD) is an important factor in urban building energy modelling (UBEM), affecting functionality and accuracy. This work assesses the impacts of the LoD of the roof, window, and zoning on a comprehensive range of outcomes (annual heating load, peak heating demand, overheating, and time-series heating error) in a representative New Zealand house. Lower-LoD roof scenarios produce mean absolute error results ranging from 1.5% for peak heating power to 99% for overheating. Windows and shading both affect solar gains, so lower-LoD windows and/or shading elements can considerably reduce model accuracy. The LoD of internal zoning has the greatest effect on time-series accuracy, producing mean absolute heating error of up to 66 W. These results indicate that low-LoD “shoebox” models, common in UBEM, can produce significant errors which aggregate at scale. Accurate internal zoning models and accurate window size and placement have the greatest potential for error reduction, but their implementation is limited at scale due to data availability and automation barriers. Conversely, modest error reductions can be obtained via simple model improvements, such as the inclusion of eaves and window border shading. Overall, modellers should select LoD elements according to specific accuracy requirements.

14 April 2025 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
SLShengyu Liu
Shengyu Liu
Wentao WuWentao Wu
Wentao Wu
XSXueqing Sun
Xueqing Sun
HTHongxin Tian
Hongxin Tian
JLJianwei Li
Jianwei Li
Xiong ShenXiong Shen
Xiong Shen

4 April 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
HYHuimin Yao
Huimin Yao
SQShanshan Qiu
Shanshan Qiu
YLYuling Lv
Yuling Lv
SWShen Wei
Shen Wei
ALAng Li
Ang Li
Xiong ShenXiong Shen
Xiong Shen
Particulate matter in Computer Numerical Control (CNC) machining workshop is harmful to workers’ health. This paper studies particulate matter transfer and the performance of various ventilation strategies in a CNC machining workshop. To obtain the boundary condition of the particle field, instruments were installed to obtain the particle size attenuation characteristics and source strength, respectively. The results show that the 99% cumulative mass concentration of particles is distributed within 1.5 μm, and the release rate of particles from the full enclosure. Next, the indoor flow field and particle field were simulated by numerical simulation with the measured boundary conditions. The working area’s age of air, particle concentration, and ventilation efficiency were compared between four displacement ventilation methods and one mixed ventilation method. The results show that the working area’s mean particle concentration and ventilation efficiency under longitudinal displacement ventilation is better than other methods. At the same time, the mean age of air is slightly worse. In addition, mixed ventilation can obtain lower mean age of air, but the particle concentration is higher in the working area. The bilateral longitudinal ventilation can be improved by placing axial circulation fans with vertical upward outlets in the center of the workshop.