Guo Zhao

Mr. Guo Zhao


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
GZGuo Zhao
Guo Zhao
HHHao Huang
Hao Huang
YYYe Yu
Ye Yu
Kun ZhaoKun Zhao
Kun Zhao
ZYZhengwei Yang
Zhengwei Yang
YZYu Zhang
Yu Zhang
In this study, the quantitative precipitation estimation (QPE) capability of three X-band dual-polarization phased array radars (PAR) in Guangzhou, South China, was demonstrated, with an S-band operational dual-polarization radar as the benchmark. Rainfall rate (R) estimators based on the specific differential phase (KDP) for summer precipitation for both X-band and S-band radars were derived from the raindrop size distributions (DSDs) observed by a 2-dimensional video disdrometer (2DVD) in South China. Rainfall estimates from the radars were evaluated with gauge observations in three events, including pre-summer rainfall, typhoon precipitation, and local severe convective precipitation. Observational results showed that radar echoes from the X-band PARs suffered much more severely from attenuation than those from the S-band radar. Compared to S-band observations, the X-band echoes can disappear when the signal-to-noise ratio drops to a certain level due to severe attenuation, resulting in different estimated rainfall areas for X- and S-band radars. The attenuation corrected by KDP had good consistency with S-band observations, but the accuracy of attenuation correction was affected by DSD uncertainty and may vary in different types of precipitation. The QPE results demonstrated that the R(KDP) estimator produced better rainfall accumulations from the X-band PAR observations compared to the S-band observations. For both the X-band and S-band radars, the estimates of hourly accumulated rainfall became more accurate in heavier rainfall, due to the decreases of both the DSD uncertainty and the impact of measurement errors. In the heavy precipitation area, the estimation accuracy of the X-band radar was high, and the overestimation of the S-band radar was obvious. Through the analysis of the ZH-ZDR distribution in the three weather events, it was found that the X-band PAR with the capability of high spatiotemporal observations can capture minute-level changes in the microphysical characteristics, which help improve the estimation accuracy of ground rainfall.

16 March 2011 in Hydrology and Earth System Sciences
Verified
Journal Article
Open access
PDF file
GZGuo Zhao
Guo Zhao
RCR. Chu
R. Chu
TZT. Zhang
T. Zhang
JLJ. Li
J. Li
JSJ. Shen
J. Shen
ZWZ. Wu
Z. Wu
During the intensive observation period of the Watershed Allied Telemetry Experimental Research (WATER), a total of 1074 raindrop size distribution were measured by the Parsivel disdrometer, the latest state-of-the-art optical laser instrument. Because of the limited observation data in Qinghai-Tibet Plateau, the modelling behaviour was not well done. We used raindrop size distributions to improve the rain rate estimator of meteorological radar in order to obtain many accurate rain rate data in this area. We got the relationship between the terminal velocity of the raindrop and the diameter (mm) of a raindrop: v(D) = 4.67D0.53. Then four types of estimators for X-band polarimetric radar are examined. The simulation results show that the classical estimator R (ZH) is most sensitive to variations in DSD and the estimator R (KDP, ZH, ZDR) is the best estimator for estimating the rain rate. An X-band polarimetric radar (714XDP) is used for verifying these estimators. The lowest sensitivity of the rain rate estimator R (KDP, ZH, ZDR) to variations in DSD can be explained by the following facts. The difference in the forward-scattering amplitudes at horizontal and vertical polarizations, which contributes KDP, is proportional to the 3rd power of the drop diameter. On the other hand, the exponent of the backscatter cross-section, which contributes to ZH, is proportional to the 6th power of the drop diameter. Because the rain rate R is proportional to the 3.57th power of the drop diameter, KDP is less sensitive to DSD variations than ZH.

28 September 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
YWYanhui Wang
Yanhui Wang
YMYingchang Min
Yingchang Min
YLYali Liu
Yali Liu
GZGuo Zhao
Guo Zhao
To improve the accuracy of pulse matching and the mapping quality of lightning discharges, the Pearson correlation method combined with empirical mode decomposition (EMD) is introduced for discharge electric field pulse matching. This paper uses the new method to locate the lightning channels of an intra-cloud (IC) lightning flash and a cloud-to-ground (CG) lightning flash and analyzes the location results for the two lightning flashes. The results show that this method has a good performance in lightning location. Compared with the pulse-peak feature matching method, the positioning results of the new method are significantly improved, which is mainly due to the much larger number of positioning points (matched pulses). The number of located radiation sources has increased by nearly a factor of seven, which can significantly improve the continuity of the lightning channel and clearly distinguish the developmental characteristics. In the CG flash, there were three negative recoil streamers in the positive leader channel. After the three negative recoil streamers were finished, taking approximately 1 ms, 12 ms, and 2 ms, respectively, the negative leader channel underwent a K-process. The three negative recoil streamers are not connected to the K-processes in the negative leader channel. We think that the three negative recoil streamers may have triggered the three K-processes, respectively.

17 August 2020 in Atmosphere
Verified
Journal Article
Open access
PDF file
BZBeilei Zan
Beilei Zan
YYYe Yu
Ye Yu
LDLongxiang Dong
Longxiang Dong
JLJianglin Li
Jianglin Li
GZGuo Zhao
Guo Zhao
TZTong Zhang
Tong Zhang
The relative importance of topography and soil moisture on the initiation of an afternoon deep convection under weak synoptic-scale forcing was investigated using the weather research and forecasting (WRF) model with high resolution (1.33 km). The convection occurred on 29 June 2017, over the Liupan Mountains, west of the Loess Plateau. The timing and location of the convective initiation (CI) simulated by the WRF model compared well with the radar observations. It showed that the warm and humid southerly airflow under 700 hPa was divided into east and west flows due to the blockage of the Liupan Mountains. The warm and humid air on the west side was forced to climb along the slope and enhanced the humidity near the ridge. The accumulation of unstable energy in the middle and north of the ridge led to a strong vertical convergence and triggered the convection. Sensitivity experiments showed that terrain played a dominant role in triggering the convection, while the spatial heterogeneity of soil moisture played an indirect role by affecting the local circulation and the partition of surface energy.

12 March 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
TMTeng Ma
Teng Ma
YYYe Yu
Ye Yu
LDLongxiang Dong
Longxiang Dong
GZGuo Zhao
Guo Zhao
TZTong Zhang
Tong Zhang
SZSuping Zhao
Suping Zhao
Wind profiling within operating wind farms is important for both wind resource assessment and wind power prediction. With increasing wind turbine size, it is getting difficult to obtain wind profiles covering the turbine-affecting area due to the limited height of wind towers. In this study, a stepwise quality control and optimizing process for deriving high-quality near-surface wind profiles within wind farms is proposed. The method is based on the radial wind speed obtained by the Doppler Wind Lidar velocity-azimuth display (VAD) technique. The method is used to obtain the whole wind profile from ground level to the height affected by wind turbines within a utility-scale onshore wind farm, in northern China. Compared with the traditional carrier-to-noise ratio (CNR) filter-based quality control method, the proposed data processing method can significantly improve the accuracy of the derived wind. For a 10 m wind speed, an increase in coefficient of determination (R2) from 0.826 to 0.932, and a decrease in mean absolute error (MAE) from 1.231% to 0.927% are obtained; while for 70 m wind speed, R2 increased from 0.926 to 0.958, and MAE decreased from 1.023% to 0.771%. For wind direction, R2 increased from 0.978 to 0.992 at 10 m, and increased from 0.983 to 0.995 at 70 m. The optimized method also presents advantages in improving the accuracy of derived wind under complex wind environments, e.g., inside a wind farm, and increasing the data availability during clear nights. The proposed method could be used to derive wind profiles from below the minimum range of a vertically operating scanning Doppler Lidar to a height affected by wind turbines. Combined with Doppler beam-swinging (DBS) scanning data, the method could be used to obtain the complete wind profile in the boundary layer. These wind profiles could be further used to predict wind power and evaluate the climate and environmental effects of wind farms.

17 September 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
YWYanhui Wang
Yanhui Wang
LYLijie Yao
Lijie Yao
YMYingchang Min
Yingchang Min
YLYali Liu
Yali Liu
GZGuo Zhao
Guo Zhao
Since the non-time-synchronized lightning positioning method does not rely on the time synchronization of the stations in the positioning system, it eliminates the errors arising from the pursuit of time synchronization and potentially achieves higher positioning accuracy. This paper provides a comprehensive overview of the errors present in the three-dimensional lightning positioning system. It compares the results of traditional positioning methods with those of non-time-synchronized lightning positioning algorithms. Subsequently, a simulation analysis of the positioning errors is conducted specifically for the non-time-synchronized lightning positioning method. The results show that (1) the non-time-synchronized lightning positioning method exhibits greater errors when utilizing two randomly positioned radiation sources for location determination. Consequently, the resulting positioning outcomes only provide a general overview of the lightning discharge. (2) The positioning outcomes resemble those of the traditional method when employing a fixed-coordinate beacon point. However, the errors in the three-dimensional positional coordinates of these fixed-coordinate beacon points significantly impact the deviations in the positioning results. This impact is positively correlated with the positional error of the beacon point, considering both the orientation and magnitude. (3) Similarly to the traditional method, the farther away from the center of the positioning network, the larger the radial error. (4) The spatial position of the selected fixed-coordinate beacon point has little influence on the error.