Nikolaos V. Tsekos

Prof. Dr. Nikolaos V. Tsekos

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2007 in Annual Review of Biomedical Engineering
Verified
Journal Article
Closed access
NTNikolaos V. Tsekos
Nikolaos V. Tsekos
AKAzadeh Khanicheh
Azadeh Khanicheh
ECEftychios Christoforou
Eftychios Christoforou
CMConstantinos Mavroidis
Constantinos Mavroidis
The continuous technological progress of magnetic resonance imaging (MRI), as well as its widespread clinical use as a highly sensitive tool in diagnostics and advanced brain research, has brought a high demand for the development of magnetic resonance (MR)-compatible robotic/mechatronic systems. Revolutionary robots guided by real-time three-dimensional (3-D)-MRI allow reliable and precise minimally invasive interventions with relatively short recovery times. Dedicated robotic interfaces used in conjunction with fMRI allow neuroscientists to investigate the brain mechanisms of manipulation and motor learning, as well as to improve rehabilitation therapies. This paper gives an overview of the motivation, advantages, technical challenges, and existing prototypes for MR-compatible robotic/mechatronic devices.

1 August 2004 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
BLBlake T. Larson
Blake T. Larson
AEArthur G. Erdman
Arthur G. Erdman
NTNikolaos V. Tsekos
Nikolaos V. Tsekos
EYEssa Yacoub
Essa Yacoub
PTPanagiotis V. Tsekos
Panagiotis V. Tsekos
IKIoannis G. Koutlas
Ioannis G. Koutlas
The objective of this work was to develop a robotic device to perform biopsy and therapeutic interventions in the breast with real-time magnetic resonance imaging (MRI) guidance. The device was designed to allow for (i) stabilization of the breast by compression, (ii) definition of the interventional probe trajectory by setting the height and pitch of a probe insertion apparatus, and (iii) positioning of an interventional probe by setting the depth of insertion. The apparatus is fitted with five computer-controlled degrees of freedom for delivering an interventional procedure. The entire device is constructed of MR compatible materials, i.e. nonmagnetic and non-conductive, to eliminate artifacts and distortion of the MR images. The apparatus is remotely controlled by means of ultrasonic motors and a graphical user interface, providing real-time MR-guided planning and monitoring of the operation. Joint motion measurements found probe placement in less than 50 s and sub-millimeter repeatability of the probe tip for same-direction point-to-point movements. However, backlash in the rotation joint may incur probe tip positional errors of up to 5 mm at a distance of 40 mm from the rotation axis, which may occur for women with large breasts. The imprecision caused by this backlash becomes negligible as the probe tip nears the rotation axis. Real-time MR-guidance will allow the physician to correct this error. Compatibility of the device within the MR environment was successfully tested on a 4 Tesla MR human scanner.

1 April 1998 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
NTNikolaos V. Tsekos
Nikolaos V. Tsekos
FZFangyi Zhang
Fangyi Zhang
HMHellmut Merkle
Hellmut Merkle
MNMasao Nagayama
Masao Nagayama
CLCostantino Ladecola
Costantino Ladecola
SKSeong‐Gi Kim
Seong‐Gi Kim

1 June 1997 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
SKSeong-Gi Kim
Seong-Gi Kim
NTNikolaos V. Tsekos
Nikolaos V. Tsekos
JAJames Ashe
James Ashe

1 August 2005 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
NTNikolaos V. Tsekos
Nikolaos V. Tsekos
AOAlpay Ozcan
Alpay Ozcan
ECEftychios Christoforou
Eftychios Christoforou
The aim of this work is to develop a remotely controlled manipulator to perform minimally invasive diagnostic and therapeutic interventions in the abdominal and thoracic cavities, with real-time magnetic resonance imaging (MRI) guidance inside clinical cylindrical MR scanners. The manipulator is composed of a three degree of freedom Cartesian motion system, which resides outside the gantry of the scanner, and serves as the holder and global positioner of a three degree of freedom arm which extends inside the gantry of the scanner. At its distal end, the arm’s end-effector can carry an interventional tool such as a biopsy needle, which can be advanced to a desired depth by means of a seventh degree of freedom. These seven degrees of freedom, provided by the entire assembly, offer extended manipulability to the device and a wide envelope of operation to the user, who can select a trajectory suitable for the procedure. The device is constructed of nonmagnetic and nonconductive fiberglass, and carbon fiber composite materials, to minimize artifacts and distortion on the MR images as well as eliminate effects on its operation from the high magnetic field and the fast switching magnetic field gradients used in MR imaging. A user interface was developed for man-in-the-loop control of the device using real-time MR images. The user interface fuses all sensor signals (MR and manipulator information) in a visualization, planning, and control command environment. Path planning is performed with graphical tools for setting the trajectory of insertion of the interventional tool using multislice and∕or three dimensional MR images which are refreshed in real time. The device control is performed with an embedded computer which runs real-time control software. The manipulator compatibility with the MR environment and image-guided operation was tested on a 1.5T MR scanner.

1 October 1995 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
NTNikolaos V. Tsekos
Nikolaos V. Tsekos
YZYi Zhang
Yi Zhang
HMHellmut Merkle
Hellmut Merkle
NWNorbert Wilke
Norbert Wilke
MJMichael Jerosch‐Herold
Michael Jerosch‐Herold
KUKǎmil Uǧurbil
Kǎmil Uǧurbil