Xi Liu

Dr. Xi Liu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2017 in Crystals
Verified
Journal Article
Open access
PDF file
XLXi Liu
Xi Liu
KZKunyu Zhuang
Kunyu Zhuang
SLShi Lin
Shi Lin
ZZZheng Zhang
Zheng Zhang
XLXuelai Li
Xuelai Li
Understanding the crystallization behavior of ice slurry under vacuum condition is important to the wide application of the vacuum method. In this study, we first measured the supercooling degree of the initiation of ice slurry formation under different stirring rates, cooling rates and ethylene glycol concentrations. Results indicate that the supercooling crystallization pressure difference increases with increasing cooling rate, while it decreases with increasing ethylene glycol concentration. The stirring rate has little influence on supercooling crystallization pressure difference. Second, the crystallization kinetics of ice crystals was conducted through batch cooling crystallization experiments based on the population balance equation. The equations of nucleation rate and growth rate were established in terms of power law kinetic expressions. Meanwhile, the influences of suspension density, stirring rate and supercooling degree on the process of nucleation and growth were studied. Third, the morphology of ice crystals in ice slurry was obtained using a microscopic observation system. It is found that the effect of stirring rate on ice crystal size is very small and the addition of ethylene glycoleffectively inhibits the growth of ice crystals. The results in this paper can provide theoretical guidance and technical support for the development of vacuum icemakers.

26 December 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XLXi Liu
Xi Liu
YLYueling Li
Yueling Li
KZKunyu Zhuang
Kunyu Zhuang
RFRuansong Fu
Ruansong Fu
SLShi Lin
Shi Lin
XLXuelai Li
Xuelai Li
In this study, the performance of ice slurry production by scraped-surface method was experimentally investigated. Temperature change characteristics, ice packing fraction (IPF) of ice slurry, power consumption of scraping system and coefficient of performance (COP) were measured by varying the concentration of sodium chloride solution, scraping speed, and solution flow rate. The effect of nanosilica on efficiency of ice slurry production was also studied. The results showed that scraping power consumption accounted for only a small proportion (about 5%) of the total power consumption of the system. An increase in the concentration of sodium chloride caused a decrease in the IPF and a decrease in the COP of the system. With the solution flow rate at 1.3 m3/h and scraping speed at 13 rpm, the maximum COP (2.43) was obtained. Furthermore, the addition of nanosilica had a significant effect on improving the system COP.

8 September 2019 in Entropy
Verified
Journal Article
Open access
PDF file
RFRuansong Fu
Ruansong Fu
JWJinhui Wang
Jinhui Wang
MZMinfeng Zheng
Minfeng Zheng
KYKaihong Yu
Kaihong Yu
XLXi Liu
Xi Liu
XLXuelai Li
Xuelai Li
The new configuration of a transcritical CO2 ejector expansion refrigeration cycle combined with a dedicated mechanical subcooling cycle (EMS) is proposed. Three mass ratios of R32/R1234ze(Z) (0.4/0.6, 0.6/0.4, and 0.8/0.2) were selected as the refrigerants of the mechanical subcooling cycle (MS) to further explore the possibility of improving the EMS cycle’s performance. The thermodynamic performances of the new cycle were evaluated using energetic and exergetic methods and compared with those of the transcritical CO2 ejector expansion cycle integrated with a thermoelectric subcooling system (ETS). The results showed that the proposed cycle presents significant advantages over the ETS cycle in terms of the ejector performance and the system energetic and exergetic performances. Taking the EMS cycle using R32/R1234ze(Z) (0.6/0.4) as the MS refrigerant as an example, the improvements in the coefficient of performance and system exergy efficiency were able to reach up to 10.27% and 15.56%, respectively, at an environmental temperature of 35 °C and evaporation temperature of −5 °C. Additionally, the advantages of the EMS cycle were more pronounced at higher environmental temperatures.

21 May 2026 in Buildings
Verified
Journal Article
Open access
PDF file
XLXINGYOU LI
XINGYOU LI
SHSongying Huang
Songying Huang
QZQichang Zeng
Qichang Zeng
MZMinfeng Zheng
Minfeng Zheng
WWWeikang Wu
Weikang Wu
XLXi Liu
Xi Liu
In hot and humid regions, urban underground utility tunnels are susceptible to high temperature and humidity due to moist inlet air, cable heat dissipation, and limited ventilation jointly affecting the internal environment. To address this issue, an alternating ventilation strategy, in which fan operation is periodically reversed to switch between air supply and exhaust, is proposed. Compared to conventional mechanical ventilation, this strategy overcomes the constraints of unidirectional airflow and mitigates thermal and humidity stratification, with low retrofit requirements and good adaptability. Ventilation performance was evaluated using non-guarantee rates for temperature and relative humidity, i.e., the ratio of the number of measurement points where the temperature/relative humidity exceeds 40 °C/65% to the total number of measurement points in the utility tunnel (TNGR and RHNGR), non-uniformity coefficients (KT and KRH), and mean temperature (Tm). The alternating mode outperformed the conventional mode, reducing TNGR by 6.0% and Tm by 0.3 °C while improving temperature and humidity distributions and lowering cable temperatures. Although the reduction in Tm appears modest, it is practically meaningful because it helps weaken thermal stratification and local overheating, improves cable operating conditions, and may reduce the need for high-airflow operation when tunnel temperatures approach the permissible limit. Response surface methodology was further used to optimize the alternating ventilation parameters, indicating that the recommended fan commutation frequency is 2 under different inlet air temperatures. CFD validation confirmed the effectiveness of the optimized scheme. At an inlet air temperature of 35 °C, KRH decreased from 11.9% to 11.0% and Tm decreased from 37.5 °C to 36.9 °C.