Xuelai Li

Dr. Xuelai Li


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XLXi Liu
Xi Liu
YLYueling Li
Yueling Li
KZKunyu Zhuang
Kunyu Zhuang
RFRuansong Fu
Ruansong Fu
SLShi Lin
Shi Lin
XLXuelai Li
Xuelai Li
In this study, the performance of ice slurry production by scraped-surface method was experimentally investigated. Temperature change characteristics, ice packing fraction (IPF) of ice slurry, power consumption of scraping system and coefficient of performance (COP) were measured by varying the concentration of sodium chloride solution, scraping speed, and solution flow rate. The effect of nanosilica on efficiency of ice slurry production was also studied. The results showed that scraping power consumption accounted for only a small proportion (about 5%) of the total power consumption of the system. An increase in the concentration of sodium chloride caused a decrease in the IPF and a decrease in the COP of the system. With the solution flow rate at 1.3 m3/h and scraping speed at 13 rpm, the maximum COP (2.43) was obtained. Furthermore, the addition of nanosilica had a significant effect on improving the system COP.

8 September 2019 in Entropy
Verified
Journal Article
Open access
PDF file
RFRuansong Fu
Ruansong Fu
JWJinhui Wang
Jinhui Wang
MZMinfeng Zheng
Minfeng Zheng
KYKaihong Yu
Kaihong Yu
XLXi Liu
Xi Liu
XLXuelai Li
Xuelai Li
The new configuration of a transcritical CO2 ejector expansion refrigeration cycle combined with a dedicated mechanical subcooling cycle (EMS) is proposed. Three mass ratios of R32/R1234ze(Z) (0.4/0.6, 0.6/0.4, and 0.8/0.2) were selected as the refrigerants of the mechanical subcooling cycle (MS) to further explore the possibility of improving the EMS cycle’s performance. The thermodynamic performances of the new cycle were evaluated using energetic and exergetic methods and compared with those of the transcritical CO2 ejector expansion cycle integrated with a thermoelectric subcooling system (ETS). The results showed that the proposed cycle presents significant advantages over the ETS cycle in terms of the ejector performance and the system energetic and exergetic performances. Taking the EMS cycle using R32/R1234ze(Z) (0.6/0.4) as the MS refrigerant as an example, the improvements in the coefficient of performance and system exergy efficiency were able to reach up to 10.27% and 15.56%, respectively, at an environmental temperature of 35 °C and evaporation temperature of −5 °C. Additionally, the advantages of the EMS cycle were more pronounced at higher environmental temperatures.