Claudia Brusasco

Dr. Claudia Brusasco

Anesthesia and Intensive Care Unit, E.O. Ospedali Galliera, Genoa, Italy
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2019 in Critical Care
Verified
Journal Article
Open access
PDF file
CBClaudia Brusasco
Claudia Brusasco
GSGregorio Santori
Gregorio Santori
EBElisa Bruzzo
Elisa Bruzzo
TRTrò Rosella
Trò Rosella
CRChiara Robba
Chiara Robba
Francesco CorradiFrancesco Corradi
Francesco Corradi
This pilot study was designed to develop a fully automatic and quantitative scoring system of B-lines (QLUSS: quantitative lung ultrasound score) involving the pleural line and to compare it with previously described semi-quantitative scores in the measurement of extravascular lung water as determined by standard thermo-dilution. This was a prospective observational study of 12 patients admitted in the intensive care unit with acute respiratory distress and each provided with 12 lung ultrasound (LUS) frames. Data collected from each patient consisted in five different scores, four semi-quantitative (nLUSS, cLUSS, qLUSS, %LUSS) and quantitative scores (QLUSS). The association between LUS scores and extravascular lung water (EVLW) was determined by simple linear regression (SLR) and robust linear regression (RLR) methods. A correlation analysis between the LUS scores was performed by using the Spearman rank test. Inter-observer variability was tested by computing intraclass correlation coefficient (ICC) in two-way models for agreement, basing on scores obtained by different raters blinded to patients’ conditions and clinical history. In the SLR, QLUSS showed a stronger association with EVLW (R2 = 0.57) than cLUSS (R2 = 0.45) and nLUSS (R2 = 0.000), while a lower association than qLUSS (R2 = 0.85) and %LUSS (R2 = 0.72) occurred. By applying RLR, QLUSS showed an association for EVLW (R2 = 0.86) comparable to qLUSS (R2 = 0.85) and stronger than %LUSS (R2 = 0.72). QLUSS was significantly correlated with qLUSS (r = 0.772; p = 0.003) and %LUSS (r = 0.757; p = 0.005), but not with cLUSS (r = 0.561; p = 0.058) and nLUSS (r = 0.105; p = 0.744). Moreover, QLUSS showed the highest ICC (0.998; 95%CI from 0.996 to 0.999) among the LUS scores. This study demonstrates that computer-aided scoring of the pleural line percentage affected by B-lines has the potential to assess EVLW. QLUSS may have a significant impact, once validated with a larger dataset composed by multiple real-time frames. This approach has the potentials to be advantageous in terms of faster data analysis and applicability to large sets of data without increased costs. On the contrary, it is not useful in pleural effusion or consolidations.

8 October 2020 in European Respiratory Journal
Verified
Journal Article
Open access
PDF file
CBClaudia Brusasco
Claudia Brusasco
Francesco CorradiFrancesco Corradi
Francesco Corradi
ADAntonia Di Domenico
Antonia Di Domenico
FRFrancesca Raggi
Francesca Raggi
GTGraziano Timossi
Graziano Timossi
VBVito Brusasco
Vito Brusasco
CPAP can be successfully used in a number of COVID-19 patients with hypoxaemic respiratory failure and gas exchange and radiological findings similar to those generally considered to be indications for invasive mechanical ventilationhttps://bit.ly/2GpBx6a

1 December 2015 in Respiratory Care
Verified
Journal Article
Closed access
PDF file
CBClaudia Brusasco
Claudia Brusasco
Francesco CorradiFrancesco Corradi
Francesco Corradi
AFAlessandra De Ferrari
Alessandra De Ferrari
LBLorenzo Ball
Lorenzo Ball
RKRobert M Kacmarek
Robert M Kacmarek
PPPaolo Pelosi
Paolo Pelosi
BACKGROUND: CPAP is frequently used in prehospital and emergency settings. An air-flow output minimum of 60 L/min and a constant positive pressure are 2 important features for a successful CPAP device. Unlike hospital CPAP devices, which require electricity, CPAP devices for ambulance use need only an oxygen source to function. The aim of the study was to evaluate and compare on a bench model the performance of 3 orofacial mask devices (Ventumask, EasyVent, and Boussignac CPAP system) and 2 helmets (Ventukit and EVE Coulisse) used to apply CPAP in the prehospital setting. METHODS: A static test evaluated air-flow output, positive pressure applied, and F IO 2 delivered by each device. A dynamic test assessed airway pressure stability during simulated ventilation. Efficiency of devices was compared based on oxygen flow needed to generate a minimum air flow of 60 L/min at each CPAP setting. RESULTS: The EasyVent and EVE Coulisse devices delivered significantly higher mean air-flow outputs compared with the Ventumask and Ventukit under all CPAP conditions tested. The Boussignac CPAP system never reached an air-flow output of 60 L/min. The EasyVent had significantly lower pressure excursion than the Ventumask at all CPAP levels, and the EVE Coulisse had lower pressure excursion than the Ventukit at 5, 15, and 20 cm H 2 O, whereas at 10 cm H 2 O, no significant difference was observed between the 2 devices. Estimated oxygen consumption was lower for the EasyVent and EVE Coulisse compared with the Ventumask and Ventukit. CONCLUSIONS: Air-flow output, pressure applied, F IO 2 delivered, device oxygen consumption, and ability to maintain air flow at 60 L/min differed significantly among the CPAP devices tested. Only the EasyVent and EVE Coulisse achieved the required minimum level of air-flow output needed to ensure an effective therapy under all CPAP conditions.

12 December 2020 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
CBClaudia Brusasco
Claudia Brusasco
GSGregorio Santori
Gregorio Santori
GTGuido Tavazzi
Guido Tavazzi
GVGabriele Via
Gabriele Via
CRChiara Robba
Chiara Robba
UGUCARE (Ultrasound in Critical care and Anesthesia Research Group)
UCARE (Ultrasound in Critical care and Anesthesia Research Group)
Discriminating acute respiratory distress syndrome (ARDS) from acute cardiogenic pulmonary edema (CPE) may be challenging in critically ill patients. Aim of this study was to investigate if gray-level co-occurrence matrix (GLCM) analysis of lung ultrasound (LUS) images can differentiate ARDS from CPE. The study population consisted of critically ill patients admitted to intensive care unit (ICU) with acute respiratory failure and submitted to LUS and extravascular lung water monitoring, and of a healthy control group (HCG). A digital analysis of pleural line and subpleural space, based on the GLCM with second order statistical texture analysis, was tested. We prospectively evaluated 47 subjects: 16 with a clinical diagnosis of CPE, 8 of ARDS, and 23 healthy subjects. By comparing ARDS and CPE patients’ subgroups with HCG, the one-way ANOVA models found a statistical significance in 9 out of 11 GLCM textural features. Post-hoc pairwise comparisons found statistical significance within each matrix feature for ARDS vs. CPE and CPE vs. HCG (P ≤ 0.001 for all). For ARDS vs. HCG a statistical significance occurred only in two matrix features (correlation: P = 0.005; homogeneity: P = 0.048). The quantitative method proposed has shown high diagnostic accuracy in differentiating normal lung from ARDS or CPE, and good diagnostic accuracy in differentiating CPE and ARDS. Gray-level co-occurrence matrix analysis of LUS images has the potential to aid pulmonary edemas differential diagnosis.

18 March 2020 in Intensive Care Medicine
Verified
Journal Article
Open access
PDF file
Francesco CorradiFrancesco Corradi
Francesco Corradi
GVG. Via
G. Via
FFFrancesco Forfori
Francesco Forfori
CBClaudia Brusasco
Claudia Brusasco
GTGuido Tavazzi
Guido Tavazzi

21 April 2022 in Critical Care
Verified
Journal Article
Open access
PDF file
Francesco CorradiFrancesco Corradi
Francesco Corradi
FGFabio Guarracino
Fabio Guarracino
GSGregorio Santori
Gregorio Santori
CBClaudia Brusasco
Claudia Brusasco
GTGuido Tavazzi
Guido Tavazzi
CVCarmelo Vullo
Carmelo Vullo
Background: To assess the usefulness of pre-operative contrast-enhanced transthoracic echocardiography (CE-TTE) and post-operative chest-x-ray (CXR) for evaluating central venous catheter (CVC) tip placements, with trans-esophageal echocardiography (TEE) as gold standard. Methods: A prospective single-center, observational study was performed in 111 patients requiring CVC positioning into the internal jugular vein for elective cardiac surgery. At the end of CVC insertion by landmark technique, a contrast-enhanced TTE was performed by both the apical four-chambers and epigastric bicaval acoustic view to assess catheter tip position; then, a TEE was performed and considered as a reference technique. A postoperative CXR was obtained for all patients. Results: As per TEE, 74 (67%) catheter tips were correctly placed and 37 (33%) misplaced. Considering intravascular and intracardiac misplacements together, they were detected in 8 patients by CE-TTE via apical four-chamber view, 36 patients by CE-TTE via epigastric bicaval acoustic view, and 12 patients by CXR. For the detection of catheter tip misplacement, CE-TTE via epigastric bicaval acoustic view was the most accurate method providing 97% sensitivity, 90% specificity, and 92% diagnostic accuracy if compared with either CE-TTE via apical four-chamber view or CXR. Concordance with TEE was 79% (p < 0.001) for CE-TTE via epigastric bicaval acoustic view. Conclusions: The concordance between CE-TTE via epigastric bicaval acoustic view and TEE suggests the use of the former as a standard technique to ensure the correct positioning of catheter tip after central venous cannulation to optimize the use of hospital resources and minimize radiation exposure.