Trò Rosella

Trò Rosella


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2019 in Critical Care
Verified
Journal Article
Open access
PDF file
CBClaudia Brusasco
Claudia Brusasco
GSGregorio Santori
Gregorio Santori
EBElisa Bruzzo
Elisa Bruzzo
TRTrò Rosella
Trò Rosella
CRChiara Robba
Chiara Robba
Francesco CorradiFrancesco Corradi
Francesco Corradi
This pilot study was designed to develop a fully automatic and quantitative scoring system of B-lines (QLUSS: quantitative lung ultrasound score) involving the pleural line and to compare it with previously described semi-quantitative scores in the measurement of extravascular lung water as determined by standard thermo-dilution. This was a prospective observational study of 12 patients admitted in the intensive care unit with acute respiratory distress and each provided with 12 lung ultrasound (LUS) frames. Data collected from each patient consisted in five different scores, four semi-quantitative (nLUSS, cLUSS, qLUSS, %LUSS) and quantitative scores (QLUSS). The association between LUS scores and extravascular lung water (EVLW) was determined by simple linear regression (SLR) and robust linear regression (RLR) methods. A correlation analysis between the LUS scores was performed by using the Spearman rank test. Inter-observer variability was tested by computing intraclass correlation coefficient (ICC) in two-way models for agreement, basing on scores obtained by different raters blinded to patients’ conditions and clinical history. In the SLR, QLUSS showed a stronger association with EVLW (R2 = 0.57) than cLUSS (R2 = 0.45) and nLUSS (R2 = 0.000), while a lower association than qLUSS (R2 = 0.85) and %LUSS (R2 = 0.72) occurred. By applying RLR, QLUSS showed an association for EVLW (R2 = 0.86) comparable to qLUSS (R2 = 0.85) and stronger than %LUSS (R2 = 0.72). QLUSS was significantly correlated with qLUSS (r = 0.772; p = 0.003) and %LUSS (r = 0.757; p = 0.005), but not with cLUSS (r = 0.561; p = 0.058) and nLUSS (r = 0.105; p = 0.744). Moreover, QLUSS showed the highest ICC (0.998; 95%CI from 0.996 to 0.999) among the LUS scores. This study demonstrates that computer-aided scoring of the pleural line percentage affected by B-lines has the potential to assess EVLW. QLUSS may have a significant impact, once validated with a larger dataset composed by multiple real-time frames. This approach has the potentials to be advantageous in terms of faster data analysis and applicability to large sets of data without increased costs. On the contrary, it is not useful in pleural effusion or consolidations.

12 December 2020 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
CBClaudia Brusasco
Claudia Brusasco
GSGregorio Santori
Gregorio Santori
GTGuido Tavazzi
Guido Tavazzi
GVGabriele Via
Gabriele Via
CRChiara Robba
Chiara Robba
UGUCARE (Ultrasound in Critical care and Anesthesia Research Group)
UCARE (Ultrasound in Critical care and Anesthesia Research Group)
Discriminating acute respiratory distress syndrome (ARDS) from acute cardiogenic pulmonary edema (CPE) may be challenging in critically ill patients. Aim of this study was to investigate if gray-level co-occurrence matrix (GLCM) analysis of lung ultrasound (LUS) images can differentiate ARDS from CPE. The study population consisted of critically ill patients admitted to intensive care unit (ICU) with acute respiratory failure and submitted to LUS and extravascular lung water monitoring, and of a healthy control group (HCG). A digital analysis of pleural line and subpleural space, based on the GLCM with second order statistical texture analysis, was tested. We prospectively evaluated 47 subjects: 16 with a clinical diagnosis of CPE, 8 of ARDS, and 23 healthy subjects. By comparing ARDS and CPE patients’ subgroups with HCG, the one-way ANOVA models found a statistical significance in 9 out of 11 GLCM textural features. Post-hoc pairwise comparisons found statistical significance within each matrix feature for ARDS vs. CPE and CPE vs. HCG (P ≤ 0.001 for all). For ARDS vs. HCG a statistical significance occurred only in two matrix features (correlation: P = 0.005; homogeneity: P = 0.048). The quantitative method proposed has shown high diagnostic accuracy in differentiating normal lung from ARDS or CPE, and good diagnostic accuracy in differentiating CPE and ARDS. Gray-level co-occurrence matrix analysis of LUS images has the potential to aid pulmonary edemas differential diagnosis.

22 September 2021 in SLEEP
Verified
Journal Article
Open access
PDF file
MRMonica Roascio
Monica Roascio
ACAndrea Canessa
Andrea Canessa
TRTrò Rosella
Trò Rosella
PMPietro Mattioli
Pietro Mattioli
FFFrancesco Famà
Francesco Famà
GAGabriele Arnulfo
Gabriele Arnulfo
Study Objectives: Increased phase synchronization in electroencephalography (EEG) bands might reflect the activation of compensatory mechanisms of cognitive decline in people with neurodegenerative diseases. Here, we investigated whether altered large-scale couplings of brain oscillations could be linked to the balancing of cognitive decline in a longitudinal cohort of people with idiopathic rapid eye-movement sleep behavior disorder (iRBD). Methods: We analyzed 18 patients (17 males, 69.7 ± 7.5 years) with iRBD undergoing high-density EEG (HD-EEG), presynaptic dopaminergic imaging, and clinical and neuropsychological (NPS) assessments at two time points (time interval 24.2 ± 5.9 months). We thus quantified the HD-EEG power distribution, orthogonalized amplitude correlation, and weighted phase-lag index at both time points and correlated them with clinical, NPS, and imaging data. Results: Four patients phenoconverted at follow-up (three cases of parkinsonism and one of dementia). At the group level, NPS scores decreased over time, without reaching statistical significance. However, alpha phase synchronization increased and delta amplitude correlations decreased significantly at follow-up compared to baseline. Both large-scale network connectivity metrics were significantly correlated with NPS scores but not with sleep quality indices or presynaptic dopaminergic imaging data. Conclusions: These results suggest that increased alpha phase synchronization and reduced delta amplitude correlation may be considered electrophysiological signs of an active compensatory mechanism of cognitive impairment in people with iRBD. Large-scale functional modifications may be helpful biomarkers in the characterization of prodromal stages of alpha-synucleinopathies.

20 February 2022 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
TRTrò Rosella
Trò Rosella
SMSimona Martini
Simona Martini
NSNicola Stagnaro
Nicola Stagnaro
VSVirginia Sambuceti
Virginia Sambuceti
MTMichele Torre
Michele Torre
MFMarco Massimo Fato
Marco Massimo Fato
Background: In clinical assessment of Pectus Excavatum (PE), the indication to surgery is based not only on symptoms but also on quantitative markers calculated from Computed Tomography (CT) or Magnetic Resonance Imaging (MRI) scans. According to clinical routine, these indexes are measured manually by radiologists with limited computer support. This process is time consuming and potentially subjected to inaccuracy and individual variability in measurements. Moreover, the existing indexes have limitations, since they are based on linear measurements performed on single slices rather than on volumetric data derived from all the thoracic scans. Results: In this paper we present an image processing pipeline aimed at providing radiologists with a computer-aid tool in support of diagnosis of PE patients developed in MATLAB® and conceived for MRI images. This framework has a dual purpose: (i) to automatize computation of clinical indexes with a view to ease and standardize pre-operative evaluation; (ii) to propose a new marker of pathological severity based on volumetric analysis and overcoming the limitations of existing axial slice-based indexes. Final designed framework is semi-automatic, requiring some user interventions at crucial steps: this is realized through a Graphical User Interface (GUI) that simplifies the interaction between the user and the tools. We tested our pipeline on 50 pediatric patients from Gaslini Children’s Hospital and performed manual computation of indexes, comparing the results between the proposed tool and gold-standard clinical practice. Automatic indexes provided by our algorithm have shown good agreement with manual measurements by two independent readers. Moreover, the new proposed Volumetric Correction Index (VCI) has exhibited good correlation with standardized markers of pathological severity, proving to be a potential innovative tool for diagnosis, treatment, and follow-up. Conclusions: Our pipeline represents an innovative image processing in PE evaluation, based on MRI images (radiation-free) and providing the clinician with a quick and accurate tool for automatically calculating the classical PE severity indexes and a new more comprehensive marker: the Volumetric Correction Index.

23 May 2022 in Frontiers in Radiology
Verified
Journal Article
Open access
TRTrò Rosella
Trò Rosella
MRMonica Roascio
Monica Roascio
DTDomenico Tortora
Domenico Tortora
MSMariasavina Severino
Mariasavina Severino
ARAndrea Rossi
Andrea Rossi
GAGabriele Arnulfo
Gabriele Arnulfo
Diffusion kurtosis imaging (DKI) has undisputed advantages over the more classical diffusion magnetic resonance imaging (dMRI) as witnessed by the fast-increasing number of clinical applications and software packages widely adopted in brain imaging. However, in the neonatal setting, DKI is still largely underutilized, in particular in spinal cord (SC) imaging, because of its inherently demanding technological requirements. Due to its extreme sensitivity to non-Gaussian diffusion, DKI proves particularly suitable for detecting complex, subtle, fast microstructural changes occurring in this area at this early and critical stage of development, which are not identifiable with only DTI. Given the multiplicity of congenital anomalies of the spinal canal, their crucial effect on later developmental outcome, and the close interconnection between the SC region and the brain above, managing to apply such a method to the neonatal cohort becomes of utmost importance. This study will (i) mention current methodological challenges associated with the application of advanced dMRI methods, like DKI, in early infancy, (ii) illustrate the first semi-automated pipeline built on Spinal Cord Toolbox for handling the DKI data of neonatal SC, from acquisition setting to estimation of diffusion measures, through accurate adjustment of processing algorithms customized for adult SC, and (iii) present results of its application in a pilot clinical case study. With the proposed pipeline, we preliminarily show that DKI is more sensitive than DTI-related measures to alterations caused by brain white matter injuries in the underlying cervical SC.

19 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MMMichele Mureddu
Michele Mureddu
TFThomas Funck
Thomas Funck
GMGiovanni Morana
Giovanni Morana
ARAndrea Rossi
Andrea Rossi
ARAntonia Ramaglia
Antonia Ramaglia
TRTrò Rosella
Trò Rosella
Background/Objectives: PET imaging with [18F]F-DOPA has demonstrated high potential for the evaluation and management of pediatric brain gliomas. Manual extraction of PET parameters is time-consuming, lacks reproducibility, and varies with operator experience. Methods: In this study, we tested whether a semi-automated image processing framework could overcome these limitations. Pediatric patients with available static and/or dynamic [18F]F-DOPA PET studies were evaluated retrospectively. We developed a Python software to automate clinical index calculations, including preprocessing to delineate tumor volumes from structural MRI, accounting for lesions with low [18F]F-DOPA uptake. A total of 73 subjects with treatment-naïve low- and high-grade gliomas, who underwent brain MRI within two weeks of [18F]F-DOPA PET, were included and analyzed. Static analysis was conducted on all subjects, while dynamic analysis was performed on 32 patients. Results: For 68 subjects, the Intraclass Correlation Coefficient for T/S between manual and ground truth segmentation was 0.91. Using our tool, ICC improved to 0.94. Our method demonstrated good reproducibility in extracting static tumor-to-striatum ratio (p = 0.357); however, significant differences were observed in tumor slope (p < 0.05). No significant differences were found in time-to-peak (p = 0.167) and striatum slope (p = 0.36). Conclusions: Our framework aids in analyzing [18F]F-DOPA PET images of pediatric brain tumors by automating clinical score extraction, simplifying segmentation and Time Activity Curve extraction, reducing user variability, and enhancing reproducibility.