Poly(2-hydroxyethyl methacrylate) (PHEMA) has been widely used in medical materials for several decades. However, the poor mechanical properties of this material have limited its application in the field of tissue engineering. The purpose of this study was to fabricate a scaffold with suitable mechanical properties and in vitro cell responses for soft tissue by using poly(HEMA-co-MMA) with various concentration ratios of hydroxyethyl methacrylate (HEMA) and methyl methacrylate (MMA). To customize the concentration ratio of HEMA and MMA, the characteristics of the fabricated scaffold with various concentration ratios were investigated through structural morphology, FT-IR, mechanical property, and contact angle analyses. Moreover, in vitro cell responses were observed according to the various concentration ratios of HEMA and MMA. Consequently, various morphologies and pore sizes were observed by changing the HEMA and MMA ratio. The mechanical properties and contact angle of the fabricated scaffolds were measured according to the HEMA and MMA concentration ratio. The results were as follows: compressive maximum stress: 254.24–932.42 KPa; tensile maximum stress: 4.37–30.64 KPa; compressive modulus: 16.14–38.80 KPa; tensile modulus: 0.5–2 KPa; and contact angle: 36.89–74.74°. In terms of the in vitro cell response, the suitable cell adhesion and proliferation of human dermal fibroblast (HDF) cells were observed in the whole scaffold. Therefore, a synthetic hydrogel scaffold with enhanced mechanical properties and suitable fibroblast cell responses could be easily fabricated for use with soft tissue using a specific HEMA and MMA concentration ratio.
In this study, we present an in situ microfluidic system to precisely control highly porous polycaprolactone microspheres as tissue templates for tissue engineering. The porosity of the microspheres was controlled by adjusting the flow rates of the polymer phase and the pore-generating material phase in the dispersed phase. The microfluidic flow-focusing technique was adopted to manufacture porous microspheres using a relatively highly viscous polymer solution, and the device was fabricated by conventional photolithography and PDMS casting. The fabricated in situ microfluidic system was used to precisely control the pore size of monodispersed polycaprolactone microspheres. The porous microspheres with controlled pore sizes were evaluated by culturing HDF cells on the surface of porous microspheres and injection into the subcutaneous tissue of rats. We found that the increased pore size of the microspheres improved the initial proliferation rate of HDF cells after seeding and relieved the inflammatory response after the implantation of porous microspheres in the subcutaneous tissue of rats.
18 December 2025 in Journal of Materials Chemistry B
C-Clear was fabricated as a fully integrated core–skirt artificial cornea through continuous polymeriztion. This unified structure provides strong mechanical stability, excellent biocompatibility, and durable 24-week in vivo integration.