G Lloyds Raja

Dr. G Lloyds Raja

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2021 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
GRG Lloyds Raja
G Lloyds Raja
AAAhmad Ali
Ahmad Ali

1 January 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
NKNikhil Kumar
Nikhil Kumar
PAPulakraj Aryan
Pulakraj Aryan
GRG Lloyds Raja
G Lloyds Raja
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
Communication delays and false data injection attacks pose significant threats to the frequency control of automatic generation systems. This paper presents a Golden Jackal Optimizer (GJO)-enhanced frequency-shifted internal model control (FIMC) scheme aimed at addressing these challenges in a dual-area thermal power system. The FIMC approach employs a pole and zero shifting variable that acts as a system robustness indicator. The paper determines an analytical search range for this variable using the Routh-Hurwitz criteria, which were later utilized by GJO. The robustness and performance of the GJO-tuned FIMC are tested against random and step load disturbances, as well as system nonlinearities. The paper models various false data injection threats, assessing the effectiveness of the GJO-tuned FIMC in neutralizing these threats under inherent communication delays. Finally, the proposed strategy is verified in real-time through hardware, employing the OPAL-RT platform. The results are compared with a recent strategy, underscoring the advanced efficacy of the proposed approach.

7 March 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
DKDeepak Kumar
Deepak Kumar
GRG Lloyds Raja
G Lloyds Raja
MAMohamed Alkhatib
Mohamed Alkhatib
ADAkash Kumar Deep
Akash Kumar Deep
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
Communication dead time (CDT) amid integration of renewable energy sources (RESs) and energy storage systems (ESSs) into modern power system networks can result in instabilities, phase lags and sluggish corrective action when dealing with frequency and tie-line power deviations. To compensate CDT, a Smith predictor based Fractional Order Proportional-Integral-Derivative with Integrator (FPIDI) controller is analytically designed for a dual-area thermal power system (TPS) with integrated RES, battery ESS, flywheel ESS and Ultra-capacitors. The FPIDI controller is designed using a modified internal model control (IMC) theory that is based on the frequency-relocated fractional-order model of the TPS. This modified IMC method eliminates the need of phase-lag inducing IMC filter. The performance-robustness tradeoff is enhanced by appropriate selection of the single tuning parameter (frequency-relocation factor ($\psi$)) by minimizing the integral of time-weighted absolute value of area control errors. The proposed controller is validated both by simulation and hardware-in-loop implementation to show its practical feasibility.


22 September 2023 in Protection and Control of Modern Power Systems
Verified
Journal Article
Open access
PDF file
NKNisha Kumari
Nisha Kumari
PAPulakraj Aryan
Pulakraj Aryan
GRG Lloyds Raja
G Lloyds Raja
Yogendra AryaYogendra Arya
Yogendra Arya
The uncertainties associated with multi-area power systems comprising both thermal and distributed renewable generation (DRG) sources such as solar and wind necessitate the use of an efficient load frequency control (LFC) technique. Therefore, a hybrid version of two metaheuristic algorithms (arithmetic optimization and African vulture's optimization algorithm) is developed. It is called the ‘arithmetic optimized African vulture's optimization algorithm (AOAVOA)’. This algorithm is used to tune a novel type-2 fuzzy-based proportional–derivative branched with dual degree-of-freedom proportional–integral–derivative controller for the LFC of a three-area hybrid deregulated power system. Thermal, electric vehicle (EV), and DRG sources (including a solar panel and a wind turbine system) are connected in area-1. Area-2 involves thermal and gas-generating units (GUs), while thermal and geothermal units are linked in area-3. Practical restrictions such as thermo-boiler dynamics, thermal-governor dead-band, and generation rate constraints are also considered. The proposed LFC method is compared to other controllers and optimizers to demonstrate its superiority in rejecting step and random load disturbances. By functioning as energy storage elements, EVs and DRG units can enhance dynamic responses during peak demand. As a result, the effect of the aforementioned units on dynamic reactions is also investigated. To validate its effectiveness, the closed-loop system is subjected to robust stability analysis and is compared to various existing control schemes from the literature. It is determined that the suggested AOAVOA improves fitness by 40.20% over the arithmetic optimizer (AO), while frequency regulation is improved by 4.55% over an AO-tuned type-2 fuzzy-based branched controller.

26 February 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
PAPulakraj Aryan
Pulakraj Aryan
GRG Lloyds Raja
G Lloyds Raja
Utkal MehtaUtkal Mehta
Utkal Mehta
TCThanga Raj Chelliah
Thanga Raj Chelliah
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
A stealthy cyberattack (SCA) aims to gradually drive the system toward instability. Although research is continuing in attack detection algorithms, a resilient control strategy is vital if SCAs go undetected for a considerable time. Especially for a controller involved in automatic generation control (AGC), resiliency becomes more crucial as the controller has to sometimes work under abnormal conditions considering that shutdown of operation is not an option. This paper introduces an innovative approach to support dual-area thermal power systems in the face of network-related challenges such as transference latency (TL) and SCAs. We propose a new tri-parametric fractional controller (TFC) that merges the advantages of proportional-integral and proportional-derivative operations, eliminating the need for additional control loops and enhancing system efficiency. The TFC's efficacy in mitigating random and step load disturbances is established, outperforming existing controllers. We employ the complex root boundary method to define the optimal parameter search space, with an improved equilibrium optimizer algorithm determining the best controller settings. The inclusion of renewable energy sources, including solar and wind, is considered, and the robustness of the system is evaluated using uncertainty norms and complementary sensitivity functions. Our approach is validated through hardware-in-loop real-time verification on the OPAL-RT platform, demonstrating superior performance in maintaining frequency stability under SCAs and TL challenges.