Mohamed Alkhatib

Mohamed Alkhatib

Auto-generated profile, based on publicly available information

Mohamed Alkhatib

Department of Electrical and Communication Engineering, United Arab Emirates University, Al Ain, Abu Dhabi, UAE

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
DKDeepak Kumar
Deepak Kumar
GRG Lloyds Raja
G Lloyds Raja
MAMohamed Alkhatib
Mohamed Alkhatib
ADAkash Kumar Deep
Akash Kumar Deep
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
Communication dead time (CDT) amid integration of renewable energy sources (RESs) and energy storage systems (ESSs) into modern power system networks can result in instabilities, phase lags and sluggish corrective action when dealing with frequency and tie-line power deviations. To compensate CDT, a Smith predictor based Fractional Order Proportional-Integral-Derivative with Integrator (FPIDI) controller is analytically designed for a dual-area thermal power system (TPS) with integrated RES, battery ESS, flywheel ESS and Ultra-capacitors. The FPIDI controller is designed using a modified internal model control (IMC) theory that is based on the frequency-relocated fractional-order model of the TPS. This modified IMC method eliminates the need of phase-lag inducing IMC filter. The performance-robustness tradeoff is enhanced by appropriate selection of the single tuning parameter (frequency-relocation factor ($\psi$)) by minimizing the integral of time-weighted absolute value of area control errors. The proposed controller is validated both by simulation and hardware-in-loop implementation to show its practical feasibility.

2 January 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Open access
SPSurya Prakash
Surya Prakash
MAMohamed Alkhatib
Mohamed Alkhatib
Hatem SindiHatem Sindi
Hatem Sindi
SASultan Alghamdi
Sultan Alghamdi
RBRanjan Kumar Behera
Ranjan Kumar Behera
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
The paper discusses the challenges in controlling a two-stage photovoltaic (PV)-based shunt active power filter (SAPF) under distorted grid conditions and stochastic PV system behavior. To address this, the paper proposes an adaptive proportional integral (API) regulator to regulate the DC-link voltage, which adapts its parameters based on the DC-link error voltage to provide low bandwidth for disturbance rejection and high bandwidth for dynamic performance enhancement. The paper also proposes an estimation method for the reference current using the sliding discrete Fourier transform and the instantaneous symmetrical component theory, which is suitable for non-ideal grid or load conditions. The accuracy of the proposed reference current estimation method is analyzed using time- and frequency-domain analysis. The performance of the PV-SAPF system with the proposed control algorithms is illustrated through simulation and real-time hardware validation under various grid conditions. Despite distorted grid conditions, the total harmonic distortion of the grid current is substantially within IEEE Std 519-2014. The proposed API regulator and reference current estimation method show promising results in improving the performance of the PV-SAPF system in the presence of internal and external disturbances.

4 June 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
BHBilal Habib
Bilal Habib
OZOmar Al Zaabi
Omar Al Zaabi
NHNoureddine Harid
Noureddine Harid
KHKhalifa Al Hosani
Khalifa Al Hosani
MAMohamed Alkhatib
Mohamed Alkhatib
Power System components are susceptible to insulation failures due to electrical and mechanical stresses, extreme environmental and operating conditions, material aging, chemical degradation and poor maintenance practices. Partial Discharge monitoring is one of the most significant metrics for health assessment of high-voltage power equipment. There are both conventional and non-conventional techniques for detection and measurement of partial discharges, and lately of the latter, the UHF method has been the focal point in non-conventional techniques. In this paper, the advantages of the UHF method are highlighted and a comprehensive review of the various UHF sensors that have been proposed in the literature is presented. The review aims at not only categorizing and describing the sensors, but more importantly examining their suitability for use in industrial applications as PD sensors for diagnosis purposes. Moreover, a thorough comparative analysis of the performance of different UHF sensors is provided using physical size, bandwidth, radiation pattern, design and optimization parameters, PD test setup and the intended application. The relative merits and limitations of each type of sensor are highlighted and a gap analysis is made. The critical area of UHF calibration has also been discussed in order to emphasis the requirement of comparable, repeatable and credible UHF measurements. Finally, considerations regarding future trends and possible topics for exploration are summarised. The review offers a valuable tool for researchers willing to acquire an overview of the state-of-the art on partial discharge monitoring using the UHF method.

24 October 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Open access
SPSurya Prakash
Surya Prakash
MAMohamed Alkhatib
Mohamed Alkhatib
OZOmar Al Zaabi
Omar Al Zaabi
KHKhalifa Al Hosani
Khalifa Al Hosani
RBRanjan Kumar Behera
Ranjan Kumar Behera
UMUtkal Ranjan Muduli
Utkal Ranjan Muduli
Modern electrical distribution networks face challenges from DC offsets and harmonics within the grid voltage, often caused by nonlinear loads or power electronics devices. This paper proposes a phase-locked loop (PLL) as an Adaptive Phase Synthesizer with In-Loop Variable Gain Control (VGC) to achieve reliable grid integration. The design of this PLL builds upon a type-3 in-loop filter based second-order generalized integrator (ISOGI), known for effective DC offset and harmonics filtering. To optimize transient performance, the ISOGI-VGC structure is introduced. The VGC controller provides dynamic bandwidth adjustment, enhancing both transient and steady-state response. Comparative simulations demonstrate the superiority of the proposed PLL design under various grid disturbances. Further validation is provided through a hardware prototype tested on a dSPACE real-time platform. The results confirm that the ISOGI-VGC-based type-3 PLL delivers improved performance and reliable grid integration.

13 January 2025 in IEEE Access
Verified
Journal Article
Open access
MTM. A. Taher
M. A. Taher
MOMohamadariff Othman
Mohamadariff Othman
HIHazlee Azil Illias
Hazlee Azil Illias
TLTarik Abdul Latef
Tarik Abdul Latef
TITengku Faiz Tengku Mohmed Noor Izam
Tengku Faiz Tengku Mohmed Noor Izam
Mousa I HusseinMousa I Hussein
Mousa I Hussein
With the exponential increase in smart device usage across various domains, flexible and conformal antenna technologies have emerged as transformative solutions, enabling wireless systems in numerous smart applications. However, selecting a suitable flexible and conformal substrate remains challenging because of the intricate characteristics and performance considerations of each material. Additionally, most applications of these substrates are confined to specific areas, such as body-worn devices, biomedical uses, and health services. In contrast, the use of ultra-high frequency (UHF, 0.3–3 GHz) antennas is largely concentrated in radio frequency identification (RFID) and telecommunications, with limited exploration in other areas. Recently, UHF antennas have gained attention for unconventional applications, including high-voltage (HV) defect detection, particularly partial discharge (PD) diagnosis. However, practical challenges arise due to the rigidity of commercial substrate materials. This paper provides a comprehensive survey on flexible and conformal UHF antennas’ applicability for PD diagnostics, a field that remains underexplored. We systematically assess the electrical, mechanical, and thermal properties of various flexible and conformal substrates relevant to UHF antenna development. In this investigation, we thoroughly analyse five substrate materials, namely polyimide (PI), polydimethylsiloxane (PDMS), Rogers laminates, polytetrafluoroethylene (PTFE), and polyethylene terephthalate (PET), and several types of UHF antennas including planar monopole, spiral antenna, Hilbert antenna, biconical antenna, and so on. The synthesis of this research delivers a complete roadmap, addressing existing limitations and proposing future directions for PD diagnosis by conformal and flexible antennas.

6 June 2025 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
SAS. M. KAYSER AZAM
S. M. KAYSER AZAM
MOMohamadariff Othman
Mohamadariff Othman
TLTarik Abdul Latef
Tarik Abdul Latef
HIHazlee Azil Illias
Hazlee Azil Illias
AKM Zakir HossainAKM Zakir Hossain
AKM Zakir Hossain
ZAZamri Zainal Abidin
Zamri Zainal Abidin
In conventional chipless RFID systems, antennas and separate resonator tags work interdependently—resonator tags rely on antennas for data transmission, while antennas alone cannot perform RFID operations without them. This research introduces, for the first time, a standalone identification antenna (SIDA), eliminating the need for supplementary resonator tags to independently perform chipless RFID functions in the far-field. SIDA is designed as a planar monopole antenna in the ultra-high frequency (UHF) range, employing a new mechanism of notch element concentration on its patch. Intermingled coupling resonators (ICRs) are utilized as notch elements to generate multi-resonating coding bits in far-field radiation. SIDA prototypes are fabricated on Rogers RO4003C substrate with distinctive 6-bit multi-resonating codes (111111 and 111101) within the 0.78–1.38 GHz range. By eliminating the need for separate resonator tags, SIDA significantly improves conventional retransmission (ReTx)- and received signal strength (RSS)-based chipless RFID operations. Both in ReTx and RSS systems, SIDA is applied as resonator tag-free far-field chipless RFID sensor for the simultaneous detection of partial discharge (PD) defect in high-voltage (HV) systems and RF identification of PD-affected HV equipment. Experimental performances prove SIDA’s suitability as far-field chipless RFID sensor and its prospect in multi-purpose smart sensing uses by eliminating the need for additional resonator tags.